Skip to content
Open access

Clinical outcomes and material-selection considerations for titanium mesh and patient-specific polyetheretherketone cranioplasty: a retrospective cohort study

Oct 2026 · Frontiers in Neurology · Vol 17 · 0 citations · 19 references
Medicine

TL;DR

PEEK was associated with fewer recorded postoperative complications and lower mean postoperative temperature, while MMSE improved within the PEEK group, and these unadjusted findings do not establish universal material superiority.

Abstract

Objective To compare outcomes after titanium mesh and patient-specific polyetheretherketone (PEEK) cranioplasty and to interpret the findings in the context of material-specific clinical indications. Methods We retrospectively analyzed 99 patients who underwent cranioplasty over four years with either titanium mesh (n = 60, 60.6%) or patient-specific PEEK implants (n = 39, 39.4%). Available demographic, operative, neurological, cognitive, postoperative inflammatory, temperature, and complication data were compared. Preoperative inflammatory markers, estimated blood loss, transfusion, and standardized patient-satisfaction outcomes were not consistently available. Results The groups differed in age and comorbidity burden (both p < 0.01) but not in sex, defect-diameter category, or operative duration. NIHSS, GOS, and MMSE scores did not change significantly within the titanium group. Within the PEEK group, NIHSS and GOS did not change significantly, whereas MMSE increased at 3 months (p = 0.005). The complication-free proportion was 41.7% in the titanium group and 64.1% in the PEEK group (unadjusted p = 0.029). Mean temperature during the first three postoperative days was 37.17 ± 0.36 °C in the titanium group and 36.91 ± 0.31 °C in the PEEK group (p < 0.01). These comparisons were unadjusted and do not establish causality. Conclusion In this retrospective cohort, PEEK was associated with fewer recorded postoperative complications and lower mean postoperative temperature, while MMSE improved within the PEEK group. These unadjusted findings do not establish universal material superiority. Implant selection should be individualized according to defect size and geometry, anatomical location, soft-tissue condition, prior infection or implant failure, cosmetic requirements, availability, and cost.

Read PDF

Similar papers

Open access Sep 2026

Residual Jaw Bone Volume and Five-Year Outcomes of Custom-Made Subperiosteal Implants: A Retrospective Study

The findings suggest that continuous volumetric assessment may serve as a useful exploratory parameter for surgical risk stratification, though predictive superiority requires validation in larger, adjusted multivariable models.

Jan Łoginoff, Zuzanna Popińska, Agata Majos et al. · 0 citations
Open access Sep 2026

Tridimensional Ridge Augmentation with Digital Customized Titanium Mesh: Radiological and Histological Evaluation. A Case Series.

OBJECTIVES To evaluate the three-dimensional bone regeneration achieved with digitally customized titanium meshes in patients presenting Cawood and Howell Class V defects, 8 months after surgery. METHODS This retrospective clinical case series included 9 patients with severe alveolar ridge atrophy (Cawood and Howell...

Franco Motta, Francesca Baldi, F. Fiori et al. · 0 citations
Open access Sep 2026

Anterior prosthetic temporization and bone regeneration: an 8-year retrospective analysis.

In this retrospective cohort, carefully adjusted interim prostheses did not appear to adversely affect bone healing or graft success, and no robust difference was demonstrated for actual bone gain, bone loss, or complications.

Zoé Gaudimier, Samy Tawfik, Elise Amblard et al. · 0 citations
Open access Aug 2026

3D-printed patient-specific guides improve screw accuracy in upper cervical spine surgery: a comparative study

Objective To evaluate the feasibility and clinical efficacy of patient-specific 3D-printed guide plates for pedicle screw placement in the upper cervical spine, compared with the conventional free-hand technique. Methods A retrospective analysis was conducted on 39 patients who underwent upper cervical spine surgery be...

Guo-Qi Niu, Ya-Long Guo, Gong Zhou et al. · 0 citations
Review Open access Oct 2026

Procedural Complications and Implant Cutout of the SpineJack®-System in Thoracolumbar Vertebral Fractures: A Retrospective Analysis of 204 Implants from a Level-1 Trauma Center

Study Design Retrospective cohort study. Objectives Implant-related complications of SpineJack® stent-kyphoplasty, particularly endplate cutout, remain poorly characterized. This study determined the incidence of procedural complications, with a focus on cutout, and identified associated factors. Methods All patients t...

Julian Scherer, Magdalena Karner, G. Osterhoff et al. · 0 citations
Aug 2026

Complications following early versus delayed craioplasty using three-dimensional titanium implants in combat-related traumatic brain injury A Prospective-Retrospective Cohort Study

Background. The optimal timing of cranioplasty (CP) following decompressive craniectomy (DC) in combat related traumatic brain injury (cTBI) remains controversial. Furthermore, comparative data on the safety and efficacy of reconstructive procedures performed at different intervals after DC, particularly with respect t...

D. T. K. Ndandja, A. Shapilov, A. V. Kim et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.