Skip to content
Preprint

CRS-Bench: A Reference-Relative Reliability Benchmark for Medical Image Encoders

Aug 2026 · 0 citations · 34 references
Engineering Computer Science

TL;DR

CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone, and summarizes these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance.

Abstract

Pretrained image encoders are central to medical image classification, where expert annotation is costly and task-specific cohorts are often limited. As the model space expands from general-purpose to broad-medical and specialty-specific encoders, selecting the representation becomes a substantive modeling decision. Clean-test discrimination alone is insufficient for this purpose: encoders with similar AUROC can differ in calibration, label efficiency, and stability under acquisition perturbations or distribution shift. We introduce CRS-Bench, a controlled benchmark for multi-objective medical encoder selection. CRS-Bench evaluates 15 pretrained encoder families across dermatology, ophthalmology, and radiology using ISIC 2019, APTOS 2019, and CheXpert, with CheXpert-to-MIMIC-CXR as an observed institutional shift, yielding 17,575 controlled run records and 3,515 seed-aggregated metric rows. Each encoder is characterized along four operational reliability dimensions: discrimination, calibration, label efficiency, and robustness. We summarize these dimensions using the Clinical Reliability Score (CRS), a Pareto-aware, reference-relative score combining dominance, profile balance, and worst-axis performance. AUROC and CRS are positively associated but not decision-equivalent: 21 of 105 pairwise orderings reverse, with a mean absolute rank displacement of 1.87. Paired-seed bootstrap analysis identifies PanDerm, MedSigLIP, and MedGemma as a stable leading reliability tier rather than a statistically resolved single leader. CRS-Bench provides a controlled framework for selecting medical image encoders from multi-axis reliability profiles rather than clean-test AUROC alone.

View source

Similar papers

Jul 2026

Self-supervision drives representational convergence in medical foundation models more than clinical supervision

Medical image encoders from different groups are increasingly treated as interchangeable, on the assumption that scale and clinical supervision concentrate their representations onto a shared structure. Whether this convergence is real, what produces it, and whether it is clinically usable are untested, and the similarity measures behind such claims are fragile. We present a controlled dissection across 18 image and 7 text encoders, all open-weight and run locally, spanning 7M to 27B parameters and five imaging modalities, including 650,982 chest radiographs from six datasets. To isolate cause, we train encoders that vary only the objective under fixed data, architecture, and scale, and reproduce the effect in a synthetic model. Convergence is modest but above a random floor, driven by the self-supervised objective, not clinical supervision: matched self-supervised encoders aligned most (40.4% on chest radiography), with label-supervised (21.1%) and image-text (3.3%) far lower, and did not grow with size (Spearman 0.302, p=0.223) or capability. It is within-modality, does not reach clinical language, and does not reproduce how radiologists judge case similarity. Yet a linear classifier transfers across encoders and to five held-out hospitals, retaining about 85% of within-encoder performance. Convergence in medical imaging is therefore set by the pretraining objective, not inherited from scale or clinical supervision. Interoperability is accordingly something to design for through that objective, and to validate where the shared geometry is weakest, across patient subgroups and against clinical judgment.

Soroosh Tayebi Arasteh, S. Ziegelmayer, Mahshad Lotfinia et al. · 0 citations
Preprint Aug 2026

ConfTriage: A Calibration-Aware LLM Triage Framework for Pulmonary Nodule Malignancy with Selective Specialist Deferral

Pulmonary nodule malignancy prediction typically depends on image-trained specialist deep learning (DL) models that require substantial annotated imaging data and task-specific training. We investigate whether a generalist large language model (LLM), reading only a faithful natural-language rendering of standard nodule attributes, can serve as a calibrated triage layer. We propose ConfTriage, a confidence-calibrated method built on three pillars: language as the modality, calibration as the safety mechanism, and a selective specialist DL backstop for low-confidence cases. We prove two guarantees: a finite-sample combined-error bound yielding an explicit per-threshold operational certificate, and an oracle inequality showing that excess risk over the Bayes-optimal deferral classifier is controlled by the L1 calibration error of the LLM probability. A controlled seven-way input ablation across five frontier LLMs on LIDC-IDRI shows that natural-language descriptions dominate the diagnostic signal, while low-level image statistics are essentially diagnostically vacuous. ConfTriage achieved an F1 score of 88.22% and an AUC of 0.92, resolving 76.5% of cases using zero-shot LLM inference alone and referring only uncertain cases to the specialist DL backstop. These results demonstrate that clinically meaningful diagnostic information can be captured through structured radiological descriptions and leveraged by calibrated LLMs for selective referral. The framework suggests a practical pathway for combining generalist LLM prediction with specialist AI models in medical decision-support systems. Source code is publicly available at https://github.com/rabiul-ai/ConfTriage.

Md Rabiul Islam, Samir Abdaljalil, E. Serpedin et al. · 0 citations
Open access Aug 2026

Medrecord-CLIP: enhancing fundus disease diagnosis via EHR-guided vision-language pre-training

This work proposes MedRecord-CLIP, a knowledge-enhanced foundation model featuring a diagnosis-guided cross-attention mechanism to adaptively extract and fuse salient patient history with diagnostic representations that highlights the critical value of integrating personalized clinical context to enhance the generalizability and interpretability of fundus foundation models.

Lei Shi, Wenbin Zhai, Lei Yu et al. · 0 citations
Preprint Sep 2026

Cross-dataset transportability of pediatric chest X-ray deep learning across three countries: discrimination, calibration, operating-point failure, and limited-label recovery

Background and Objective: External evaluation of medical-imaging AI is often collapsed into discrimination. We evaluated a computational protocol that separately tests discrimination, probability calibration, fixed operatingpoint transport, shortcut-associated signal, and limited-label recoverability for pediatric pneumonia classification across datasets from three countries. Methods: After exact-duplicate removal, 5,824 Guangzhou radiographs supported leakage-controlled source development and internal testing. A frozen three-seed DenseNet121 dual-view ensemble was evaluated zero-shot on BDCXR-3257 from Bangladesh (n = 3, 257) and an untouched harmonized VinDr-PCXR/PediCXR test cohort from Vietnam (n = 1, 077). Matched seed-42 variants tested architectural robustness. Secondary BDCXR analyses used a fixed 651-image adaptation pool and 2,606-image hold-out; 163, 326, and 651 labels represented 5%, 10%, and 20% of complete BDCXR. Results: Internal AUROC was 0.976 with 95.1% sensitivity. BDCXR and VinDr-PCXR AUROC were 0.798 and 0.742, while frozen-threshold sensitivity fell to 6.2% and 0%. Source-to-BDCXR AUROC degradation occurred for a full-image baseline (0.961 to 0.749), ungated dual-view model (0.977 to 0.766), and gated MixStyle model (0.966 to 0.789). With 163 BDCXR labels, Platt recalibration preserved AUROC while increasing held-out sensitivity to 88.3%, but specificity was 47.9% and the alert rate was 78.5%. Two hundred repeated 163-label fits confirmed sensitivity recovery but substantial specificity variability. Conclusions: Cross-dataset shifts across countries affected ranking, probability alignment, and source-defined decision behavior differently. Transport studies should evaluate these components separately and quantify the operational burden of apparent recovery.

Nazim-E-Alam · 0 citations
#small language model Preprint Aug 2026

Label-Free Foundational Model Selection for Medical Image Classification under Distribution Shift via Pseudo Label Discrepancy

This work proposes a label-free selection criterion built on SUDO, a framework for evaluating clinical AI systems without ground-truth annotations, and shows that AURCC can be used to rank a variety of vision-language models on chest X-ray classification across three inter-hospital shift scenarios, under zero-shot and MLP-probe regimes.

Juan Iñaki Larrea, L. Mansilla, Enzo Ferrante · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.