Sep 2026· E -journal of dentistry· pp.
107075
· 0 citations· 27 references
Medicine
TL;DR
The simultaneous-capture protocol may improve the recording of adjacent implant relationships without auxiliary devices and its clinical effectiveness and the separate contributions of concurrent visualization, scanner trajectory, and tip inclination require further investigation.
Abstract
Objective
To evaluate the effect of sequential and simultaneous capture strategies on the interimplant positional trueness of intraoral scans for two adjacent implants in different implant configurations.
Methods
Two distal-extension partially edentulous maxillary models were used: a short-span implant configuration with an 8.5-mm interimplant span simulating two-unit splinted crowns and a long-span implant configuration with a 15.0-mm span simulating a three-unit fixed dental prosthesis. Reference scans were obtained using a desktop scanner, and test scans were acquired using an intraoral scanner. Sequential and simultaneous capture strategies were evaluated using 10 repeated scans per strategy for each model. Trueness of the relative interimplant relationship was assessed using absolute linear and angular interimplant discrepancies. Data were analyzed using two-way ANOVAs, supplemented by a two-way MANOVA (α = .05).
Results
A significant interaction between capture strategy and implant configuration was observed for linear discrepancy (p = .009), whereas the interaction was not significant for angular discrepancy (p = .233). Simultaneous capture resulted in lower linear discrepancies than sequential capture in the short-span (7.21 ± 3.97 versus 24.60 ± 7.65 µm) and long-span (13.84 ± 4.63 versus 46.53 ± 14.36 µm) configurations (both p < .001). Angular discrepancies were also lower with simultaneous capture in the short-span (0.052 ± 0.019° versus 0.096 ± 0.028°; p = .045) and long-span (0.162 ± 0.059° versus 0.242 ± 0.065°; p < .001) configurations.
Conclusions
Within the two model configurations tested, the simultaneous-capture protocol produced lower mean linear and angular interimplant discrepancies than the sequential-capture protocol.
CLINICAL
Significance
The simultaneous-capture protocol may improve the recording of adjacent implant relationships without auxiliary devices. Its clinical effectiveness and the separate contributions of concurrent visualization, scanner trajectory, and tip inclination require further investigation.
OBJECTIVE
This in vitro feasibility study evaluated the agreement between virtual implant positions obtained from intraoral scans of a tissue-level implant with and without a scan body for single-crown restorations.
METHODS
Three intraoral scanners (TRIOS 5 (TRI), Primescan (PRI), and DCS Scan (DCS)) were used to dig...
F. Burkhardt, Ahmad Amro Baradee, B. Spies et al.· E -journal of dentistry· 0 citations
OBJECTIVE
To evaluate the effect of implant-soft tissue alignment protocols on trueness of implant positions relative to soft-tissue scan using intraoral photogrammetry (IPG), comparing four coded scan body protocols with a cap scan body protocol.
METHODS
A maxillary edentulous model with four parallel implant abutme...
Siraphob Techapiroontong, Veerit Tanvarasethee, W. Tumrasvin et al.· E -journal of dentistry· 0 citations
The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...
Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al.· Journal of Esthetic and Rest...· 0 citations
This in vitro study evaluated whether the presence of four remaining teeth affected the reproduction of interabutment spatial relationships by two intraoral scanning systems. A single three-dimensionally printed maxillary master model containing four implant analogues connected to Mini Conical Abutments was evaluated s...
Lucas David Galvani, Kathleen Lemos Soares, Jailson Junior Rodrigues Oliveira et al.· Applied Sciences· 0 citations
AIM
To evaluate and compare the positional accuracy of complete arch intraoral digital implant scans obtained using a conventional scan body protocol and a customized metallic ring-based calibrated framework.
MATERIALS AND METHODS
A completely edentulous arch restored with six implants was scanned using two complete...
Miguel Gómez-Polo, Solange Vasquez-Ramos, Marta Revilla-León et al.· Clinical Oral Implants Resea...· 0 citations
This study indicates that direct intraoral scanning provides superior accuracy compared with RSTs, particularly in the posterior regions, whereas putty-only impressions exhibited substantially greater relative deviations, particularly in the posterior regions.
Sumit Deshpande, Diksha Rajkumar Kasnale, Konark N. Patil et al.· European Journal of Dentistr...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.