Digital impressions showed accuracy comparable to conventional impressions for short-span posterior implant restorations and can be considered a reliable alternative for routine clinical application.
Abstract
Because an incorrect transfer of 3D implant sites might result in an ill-fitting prosthetic replacement with problems including peri implantitis, screw loosening, screw fracture, prosthesis or implant fracture, precise implant impressions are crucial. Therefore, it is of interest to evaluate and compare the accuracy of digital and conventional implant impression techniques in partially edentulous cases with two posterior implants. Fifteen patients underwent both conventional polyvinyl siloxane impressions and digital intraoral scanning and the resulting master models were analyzed using laboratory scanning and three-dimensional reverse engineering software to assess inter-implant distance, angulation, rotation and surface mismatch. There was statistically insignificant differences were noted between the two impression techniques for inter-implant distance, angulation, rotation, or distal implant surface mismatch, whereas a significantly greater mesial implant surface mismatch was found with the digital impression technique (p = 0.02484). Strong positive correlations were observed between the two techniques for distance, angulation and rotation, while a moderate positive correlation was noted for mesial and distal implant surface mismatch. Thus, digital impressions showed accuracy comparable to conventional impressions for short-span posterior implant restorations and can be considered a reliable alternative for routine clinical application.
Digital and conventional impressions showed comparable overall three-dimensional accuracy under random-effects models; however, the certainty and generalizability of the pooled estimates are limited by extreme heterogeneity, sparse clinical evidence, and subgroup analyses with limited data.
S. Taherzadeh, Samaneh Kalantari· Galen medical journal· 0 citations
Statement of problem: To what extent the accuracy of digital impressions
compared with conventional impressions is sufficiently accurate or not.
Comparative clinical evidence are confined, emphasizing the need for studies
evaluating and comparing the accuracies between both types of impressions for
implant supported re...
Sheetal Aggarwal, Rajani Kalla, S. Bhansali et al.· European Journal of Prosthod...· 0 citations
The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...
Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al.· Journal of Esthetic and Rest...· 0 citations
In this illustrative dataset, digital impressions demonstrated lower RMS, linear, and angular deviations relative to the reference model compared with conventional impressions, suggesting a trend towards higher overall accuracy for the digital workflow.
Mahmoud abdoulGawy, Adel Ahmed· Libyan journal of medical re...· 0 citations
Accurate impression making is essential for achieving passive fit and long-term success of All-on-4 implant-supported prostheses, and this study compared the accuracy of conventional and digital impression techniques for maxillary and mandibular All-on-4 restorations. Sixty impressions were allocated into four groups (...
BACKGROUND
Accurate implant placement is essential for predictable functional and esthetic outcomes. Although static computer-assisted implant surgery (s-CAIS) is more accurate than freehand placement, the effects of increasing guidance within partially guided workflows and on adjacent-implant relationships remain uncl...
Eric C. MacFadden, Christopher Sobczak, A. Guentsch· Clinical Oral Implants Resea...· 0 citations