Abstract
We report a fiber-optic tuning-fork–cantilever coupled photoacoustic (TFCC-PA) sensor for the simultaneous detection of methane (CH 4 ) and acetylene (C 2 H 2 ). The sensor integrates a custom square-head 6063 aluminum-alloy tuning fork (ATF) and a laser-cut polyethylene terephthalate cantilever within a single nonresonant photoacoustic cell. Synchronous dual-channel readout is achieved using two Fabry–Perot (F–P) white-light interferometers combined with frequency-division-multiplexed demodulation. The low-frequency cantilever is suited to slowly relaxing CH 4 , whereas the higher-frequency tuning fork is used to detect rapidly relaxing C 2 H 2 . Following structural optimization using COMSOL Multiphysics, experiments confirmed well-separated operating frequencies with negligible interchannel crosstalk. Both gases exhibited linear concentration responses with R 2 values of 0.99. At an integration time of 1 s, the detection limits were 6.54 ppm for CH 4 and 1.06 ppm for C 2 H 2 . Allan–Werle analysis yielded minimum detection limits of 167 ppb and 96.5 ppb, respectively. The proposed TFCC-PA sensor provides a robust and intrinsically safe solution for high-sensitivity multicomponent gas sensing applications.