Abstract

Background

Management of complex anal fistulas is challenging. Draining-setons are commonly used to control sepsis and prepare for surgery. This study compared outcomes of seton placement in patients with and without Crohn's disease (CD).

Methods

We retrospectively reviewed patients with complex anal fistulas undergoing non-cutting seton placement (2013-2022), without plans for definitive surgery. The primary outcome was one-year seton failure, defined as recurrent abscess, new fistula, or need for reintervention. Multivariate analysis identified factors associated with failure.

Results

Ninety-nine patients were included (73 CD, 26 non-CD). One-year seton failure was higher in CD patients (58% vs. 23%, p = 0.003), driven by increased fistula formation and need for additional setons. On multivariate analysis, CD (HR 2.5), family history of IBD (HR 2.3), prior anorectal surgeries, and steroid use (HR 3.2) were associated with failure.

Conclusion

Seton outcomes are worse in CD, supporting its role as a temporizing rather than definitive treatment strategy.