Skip to content
#machine learning #computer vision Preprint Open access

Posterior Variance Is a Constraint Map, Not an Error Map: Closed-Form Uncertainty for Radiative Gaussian Splatting in Sparse-View CT

Chulin Zhao Yiran Xu Shu Liu
Sep 2026
Machine Learning Computer Vision

Abstract

Radiative Gaussian splatting reconstructs sparse-view CT fast and accurately, and recent work attaches per-Gaussian posteriors to yield per-voxel uncertainty maps. We ask what such a map actually measures: posterior variance is a data-constraint map, not an error map -- its alarms are trustworthy, its all-clears are not. Exploiting the strict linearity of X-ray rendering in the per-Gaussian densities, we derive a clamp-aware closed form that the unchanged rasterizer evaluates exactly in one forward pass, in volume and projection space: the infinite-sample limit of the sampling estimator of concurrent work, at ~8x lower cost. On the official 15-scene benchmark this uncertainty ranks true error on 14 of 15 scenes. Restricted to the object interior -- the tissue a clinician reads -- the ranking collapses (median Spearman 0.11, 0/15 pass), identically for a deep ensemble and for a strictly positive log-normal posterior: three constructions, two estimator families, no survivors. The mechanism is structural: about 90% of in-object error is bias that reproduces across retrainings, invisible to model disagreement; 73-81% of the full-volume correlation is carried by object/surround contrast; and an exactly solvable control puts the observed in-object ranking 4-5x below what a perfectly calibrated posterior with the same sigma-spread would score. The error scale, by contrast, is an engineering problem, and we solve it: reparameterizing the posterior contracts the cross-scene temperature spread from 19.3x to 2.6x, one scene-agnostic temperature transfers to unseen scenes (10/15 leave-one-scene-out), and the repaired scale tracks photon count at the Poisson-predicted -1/2 power. We distill evaluation practice that would have caught the illusion -- masked calibration, seed-wise bias decomposition, an exact-posterior reference -- and release all protocols, seeds and per-run evidence.

View source

Similar papers

#computer vision Review Sep 2017

Agile Software Development Methods: Review and Analysis

This publication proposes a definition and a classification of agile software development approaches and analyses ten software development methods that can be characterized as being "agile" against the defined criterion.

P. Abrahamsson, O. Salo, Jussi Ronkainen et al. · 727 citations · ⚡54
#computer vision Jun 2008

The impact of agile practices on communication in software development

The study shows that agile practices improve both informal and formal communication, but indicates that, in larger development situations involving multiple external stakeholders, a mismatch of adequate communication mechanisms can sometimes even hinder the communication.

M. Pikkarainen, Jukka Haikara, O. Salo et al. · 401 citations · ⚡48
#machine learning Review Open access Oct 2014

Software development in startup companies: A systematic mapping study

The results indicate that software engineering work practices are chosen opportunistically, adapted and configured to provide value under the constrains imposed by the startup context.

Nicolò Paternoster, Carmine Giardino, M. Unterkalmsteiner et al. · 394 citations · ⚡54

Diffusion models as plug-and-play priors

The possibility of inferring high-dimensional data inference in a model that consists of a prior and an auxiliary differentiable constraint given some additional information is considered, thereby allowing a range of potential applications in adapting models to new domains and tasks.

Alexandros Graikos, Esmeralda S. Whitammer, N. Jojic et al. · 316 citations · ⚡15

Related blog posts

Microsoft Research Blog Aug 11, 2026

Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement

Radiology AI is evolving beyond report generation. CARE-X explores a unified approach that combines flexible reasoning, calibrated predictions, and measurement-based tools for chest X-ray interpretation. The post Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement appeared first on Microsoft Research.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.