Skip to content
Open access

Tomographic quality evaluation of flexible x-ray scintillating imaging skins

Sep 2026 · Biomedical engineering and physics express · Vol 12, pp. 055024 · 0 citations · 37 references
Physics Medicine

TL;DR

The feasibility of 3D x-ray imaging using imaging skins directly placed onto the imaged object has been demonstrated, achieving high resolution, comparable to clinical CT.

Abstract

Objective. Detecting abnormal tissue in minimally invasive surgery is challenging due to the lack of direct palpation for the surgeon, with visualisation often being limited to white light endoscope images of the tissue surface, providing no information about inner structures. Imaging skins are being explored as a novel method of surgical image guidance: they are flexible and stretchable scintillating films that can act as indirect x-ray detectors when placed directly on the organ surface. Approach. Tomographic imaging of a custom quality evaluation phantom was performed using the imaging skin system. Image quality metrics, including spatial resolution, contrast, and uniformity, were obtained and compared to a conventional flat-panel micro-CT system. Main results. The imaging skin scan achieved a spatial resolution of 3.11 lp mm −1 at 10% contrast. While these results were worse than that of the micro-CT system, the imaging skin system still met the requirements for clinical CT, demonstrating its clinical suitability. Significance. The feasibility of 3D x-ray imaging using imaging skins directly placed onto the imaged object has been demonstrated, achieving high resolution, comparable to clinical CT. Future work will involve artefact corrections and more advanced reconstruction techniques for the intended application of imaging skins for real-time surgical guidance.

Read PDF

Similar papers

Open access Sep 2026

Multidimensional Quality Evaluation of Imaging Performance for Musculoskeletal Ultrasound Computed Tomography System

Core parameters of the Musculoskeletal Ultrasound Computed Tomography System (MUCTS), such as spatial resolution, slice thickness, and three-dimensional reconstruction volume error, directly determine imaging performance and clinical diagnostic accuracy. To objectively and systematically assess the imaging quality and...

Xiao-Xue Bai, Li Zhao, Pan Zhou et al. · 0 citations
Open access Sep 2026

Noise-robust high-fidelity ultrasound imaging with a flexible silicone-based metalens

Ultrasound imaging has been extensively employed in biomedical diagnosis and clinical research, owing to its compelling merits of non-ionizing radiation, cost-effectiveness, and real-time visualization. However, conventional ultrasound imaging systems are fundamentally constrained by diffraction-limited spatial resolut...

Jia-Jie He, Jun-Hao Jiang, Hai-Jun Luo et al. · 0 citations
Review Open access Oct 2026

Dermoscopy at an Inflection Point: Sharper Criteria, New Optics, and the Arrival of Artificial Intelligence

Dermoscopy improves the diagnosis of melanoma and keratinocyte carcinoma, but its value depends on the observer, the lesion mix, the anatomic site, and the action taken after the examination. Recent reviews have mainly focused on one modality or image-classification accuracy. This narrative review follows the clinical...

Dana N. Pham, Warren H. Chan, Jade Conway et al. · 0 citations
Open access Oct 2026

A liquid fiducial marker for image-guided proton beam therapy of abdominal tumors.

PURPOSE This study compared a liquid to solid fiducial markers regarding visibility, artifact characteristics on X-ray imaging and dose perturbation for image-guided proton therapy (IGPT) of abdominal tumors. Additionally, the radio-opaque composition of the liquid fiducial marker was optimized, and the chemical stabil...

S. Stefanowicz, J. Henriksen, R. Jølck et al. · 0 citations