Skip to content

Influence of implant scan body material and intraoral scanner system on the accuracy of three-unit implant scans.

Sep 2026 · The Journal of prosthetic dentistry (Print) · 0 citations · 34 references
Medicine

TL;DR

Within the limitations of this in vitro study, iTL demonstrated higher trueness and precision than the other IOSs tested, whereas PEEK and hybrid ISBs demonstrated higher trueness for 3-unit implant scans.

Abstract

STATEMENT OF PROBLEM The accuracy of implant scans may be influenced by the intraoral scanner (IOS) system and the intraoral scan body (ISB) materials. However, evidence regarding their impact remains limited.

Purpose

The purpose of this in vitro study was to evaluate the trueness and precision of 3-unit implant scans using different ISBs and IOSs. MATERIAL AND

Methods

Two implants were placed in the right first premolar and first molar regions of a mandibular typodont model, and a 3-dimensional printed replica was fabricated. Three ISBs (Hybrid, polyetheretherketone [PEEK], titanium) were scanned using 3 IOSs: CEREC Primescan (CP), iTero Lumina (iTL), TRIOS 5 (T5). An industrial blue-light scanner (ATOS) served as the reference. Trueness was evaluated by superimposing experimental scans onto the reference scan, and precision by superimposing repeated scans of the same IOS. Three-dimensional discrepancy values were statistically analyzed with Kruskal-Wallis and pairwise comparisons with Bonferroni (α=.05).

Results

iTL demonstrated higher trueness and precision than other IOSs for all ISB groups (P<.05). Titanium ISBs showed lower trueness than PEEK and hybrid ISBs (P<.05), whereas no significant differences were observed between PEEK and hybrid ISBs (P>.05). For precision, significant differences among ISBs were observed only within the iTL group (P<.05); the titanium ISB showed the lowest precision.

Conclusions

Within the limitations of this in vitro study, iTL demonstrated higher trueness and precision than the other IOSs tested, whereas PEEK and hybrid ISBs demonstrated higher trueness for 3-unit implant scans.

View source

Similar papers

Oct 2026

Accuracy of full-arch implant scans using different horizontal scan bodies in an angulated model: An in vitro study

Background/purpose Various newly developed horizontal implant scan bodies have been introduced to enhance full-arch scan accuracy. However, their performance in angulated implant scenarios remains unclear. The purpose of this study was to evaluate the accuracy of four specific horizontal scan body systems. Materials an...

Tsung-Yu Lin, Tong-Mei Wang, Li-Deh Lin · 0 citations
Open access Sep 2026

Digitization of a Single Tissue-Level Implant Without Scan Body - A Feasibility Study.

OBJECTIVE This in vitro feasibility study evaluated the agreement between virtual implant positions obtained from intraoral scans of a tissue-level implant with and without a scan body for single-crown restorations. METHODS Three intraoral scanners (TRIOS 5 (TRI), Primescan (PRI), and DCS Scan (DCS)) were used to dig...

F. Burkhardt, Ahmad Amro Baradee, B. Spies et al. · 0 citations
Open access Sep 2026

Accuracy of intraoral scanners and photogrammetry for full-arch implant-supported rehabilitations: an in vitro study

Objectives: This in vitro study aimed to compare the accuracy of intraoral scanning and photogrammetry-based acquisition methods for full-arch implant-supported rehabilitations involving four and six implants. Methods: An acrylic edentulous mandible was used to simulate the clinical setting. Implant positions were acqu...

R. Pinto, J. Martins, José Navarro et al. · 0 citations
Open access Oct 2026

The effect of intraoral scanner tip size and scanning strategy on the digital impression trueness of full-arch implant-supported prostheses: an in vitro study

PURPOSE The purpose of this in vitro study was to evaluate the effect of scanner head size, scanning path, and scanning strategy on the trueness of complete-arch digital implant impressions in an edentulous maxilla. MATERIALS AND METHODS An edentulous maxillary model with four implants was digitized using a laboratory...

A. Öztürk, A. Ertan · 0 citations
Open access Oct 2026

Comparative Evaluation of the 3-Dimensional Implant Impression Accuracy between Conventional and Digital Impression Using Two Different Intraoral Scanners: An In Vivo Study

Background: Accurate three-dimensional (3D) recording of implant positions is fundamental to achieving passive fit and long-term success of implant-supported prostheses. The growing adoption of digital intraoral scanners (IOS) necessitates rigorous clinical evaluation of their accuracy relative to established conventio...

Rahul Ranjan, Anju Aggarwal, Punit R. S. Khurana et al. · 0 citations
Open access Oct 2026

Trueness and precision of 5 intraoral scanners under different conditions in arches: A 3D comparative in vitro analysis.

BACKGROUND The accuracy of intraoral scanners (IOSs) has been widely reported. However, studies comparing their performance under different clinical conditions are lacking. OBJECTIVES The aim of the present study was to compare the trueness and precision of 5 IOSs across 4 anatomically distinct models simulating comm...

A. Polizzi, Pietro Venezia, Sara Serra et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.