Partial discharge monitoring of oil-immersed current transformers (CTs) is susceptible to electromagnetic interference, and single-parameter detection is biased due to incomplete information. To further improve the safety of the oil-immersed CT, an insulation diagnosis method combining hierarchical detection with Dempster–Shafer evidence (D-S) theory is proposed in this paper. A three-step diagnostic framework is constructed. At the first step, the liquid level is monitored since it changes with the gas generated by partial discharge. If an abnormality is identified in the first-step screening, features of partial discharge and oil chromatography are synchronously collected at the second step. At the third stage, the basic probability assignment (BPA) of evidence is constructed by adopting the Sigmoid membership function. Two types of diagnostic results, including normal state and discharge fault, are output through D-S evidence theory fusion. The unique contribution of this work lies in using simple oil level monitoring as a trigger for high-precision partial discharge (PD) and dissolved gas analysis (DGA) detection, which significantly reduces the diagnostic cost. Furthermore, by fusing the two evidence sources with D-S theory, the diagnostic reliability for oil-immersed CTs is improved. To verify the proposed method, tests are performed on a 110 kV oil-immersed CT. It is demonstrated that the rise in oil level is observable. Partial discharge signals are often mistaken for false pulses, while oil chromatography data has excellent anti-electromagnetic interference performance and can stably reflect the cumulative deterioration state of insulation. Restricting false partial discharge signals by oil chromatography data can reduce the misjudgment tendency caused by noise. After D-S evidence fusion, the fault confidence level is increased from 0.68 to 0.83, and the diagnostic uncertainty is reduced from 0.13 to 0.02, which effectively alleviates the ambiguity caused by the single partial discharge detection method. A cost analysis, compared with the PD and DGA fully installation scheme, further shows that the proposed scheme has significant cost advantage because the practical failure rate is far below the break-even value of 98.44%. The scheme proposed in this paper significantly improves the online insulation assessment accuracy for high-voltage current transformers via the hierarchical monitoring framework.
Oil-paper insulation is considered the most popular method for insulating the windings within power transformers because of its ability to withstand high electrical and thermal stress. During the life time of power transformers, oil-paper insulation is aged, and hydrocarbon gases are released. Dissolved gas analysis (D...
R. El-Aal, D. Mansour, A. Hassan et al.· Jordan journal of electrical...· 0 citations
A two-tier cascaded assessment framework based on multi-dimensional feature extraction and Dempster-Shafer (D-S) decision fusion is proposed to address the physical blind spots inherent in single-parameter monitoring and the boundary ambiguity caused by high-noise environments during the insulation deterioration of 10...
Ke-Yu Yue, Da-Long Fu, Zi-Qin Zhou et al.· European Conference on Elect...· 0 citations
Conventional condition assessment methods applied to oil-immersed transformers rely on offline detection and exhibit low efficiency in video feature extraction. A video-based online fault diagnosis model is developed in this study by integrating the Grey Wolf Optimizer and a Back Propagation neural network. This model...
To address the limitations of conventional inter-turn short-circuit fault identification in transformers, which relies on a single monitoring parameter and fails to fully exploit the complementary characteristics of heterogeneous multi-source information, a multi-parameter fault identification method based on informati...
A quantitative, measurement-oriented diagnostic framework based on the advanced normalized Multi-Domain Fault Deviation Index (MFDI) is proposed, which provides quantitative differentiation among the investigated fault conditions despite the high similarity of their corresponding spectral signatures.
Cemal Keleş, M. Mamiş, M. Arkan et al.· Scientific Reports· 0 citations
Traditional contact-based vibration measurements can be affected by sensor installation and mechanical coupling, which complicates feature extraction for dry-type transformer core diagnosis. This study evaluates a fault-diagnosis workflow combining laser Doppler vibrometry (LDV), Gramian angular field (GAF) encoding an...
Chun-Hua Fang, Yu-Kai Li, Lan Jiang et al.· Engineering Research Express· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.