Aug 2026· Multidisciplinary Science Journal· Vol 9, pp. 2027210· 0 citations· 19 references
TL;DR
The observed reductions in FVC and FEV₁ indicate decreased lung volumes, while the decline in FEF₂₅–₇₅ suggests early impairment of small airway function despite preserved large airway patency.
Abstract
Air conditioning (AC) systems are widely used in modern indoor environments to provide thermal comfort; however, prolonged exposure to cold and dry air may adversely affect respiratory physiology even in healthy individuals. This comparative cross-sectional study evaluated the impact of long-term exposure to air-conditioned environments on pulmonary function parameters in healthy, nonsmoking adults. A total of 400 participants aged 25–45 years were enrolled and divided equally into two groups: 200 regular AC users (≥6 hours/day for at least one year) and 200 non-AC users. Anthropometric characteristics were comparable between the groups. Pulmonary function tests were performed using a standardized spirometer, assessing forced vital capacity (FVC), forced expiratory volume in one second (FEV₁), peak expiratory flow rate (PEFR), FEV₁/FVC ratio, and forced expiratory flow at 25–75% (FEF₂₅–₇₅). The results demonstrated that AC users had significantly lower mean FVC (3.73 ± 0.51 L vs 3.93 ± 0.51 L), FEV₁ (3.05 ± 0.53 L vs 3.25 ± 0.53 L), and FEF₂₅–₇₅ (1.92 ± 0.61 L/s vs 2.02 ± 0.61 L/s) compared to non-AC users (p < 0.05). In contrast, PEFR (620.9 ± 150.8 vs 618.6 ± 147.4 L/min) and FEV₁/FVC ratio showed no meaningful differences between the groups. The observed reductions in FVC and FEV₁ indicate decreased lung volumes, while the decline in FEF₂₅–₇₅ suggests early impairment of small airway function despite preserved large airway patency. These findings highlight that chronic exposure to air-conditioned environments may lead to subtle but clinically relevant alterations in pulmonary function even in asymptomatic individuals. The study underscores the importance of maintaining optimal indoor air quality, including adequate humidity control and regular maintenance of AC systems. Further longitudinal and multicentric studies are warranted to confirm causality and assess long-term respiratory health implications.
Introduction: Hypertension’s impact on global health is vast, yet its link to Indian pulmonary function remains unclear. Despite maintaining controlled blood pressure, hypertensive individuals may harbour undetected pulmonary deficits, necessitating a closer look at the intersection of cardiovascular and respiratory he...
Sujoy Mukherjee, Debalina Sengupta, P. Sinha et al.· Journal of Clinical and Diag...· 0 citations
BACKGROUND
Residential wood combustion is a major source of ambient particulate matter in Northern Europe and is associated with adverse respiratory health outcomes. However, the acute effects of short-term wood smoke exposure on small airways remain incompletely characterized.
OBJECTIVE
To investigate the acute effe...
Maria Sehlin, F. Öhberg, C. Boman et al.· Environmental Research· 0 citations
Epidemiologic studies have provided evidence of health effects over cumulative days of PM2.5 exposure in observational settings; however, there have been no controlled exposure studies in humans over consecutive days. To assess the effects of near-ambient PM2.5 exposure on pulmonary function and exercise tolerance, a...
Jairus C. Pulczinski, Corinna Y. Keeler, A. Rappold et al.· Environmental Health Perspec...· 0 citations
Background: Jute processing generates organic dust capable of affecting respiratory function following prolonged occupational exposure. This study evaluated pulmonary function among workers chronically exposed to jute-mill dust compared with non-exposed individuals.
Methods: This comparative observational study include...
N. Sheela, Potnuri Karunakar, Sunitha Pothala et al.· Journal of Medicine Pharmaco...· 0 citations
Background/Objectives: The aim of this study was to test the association of poorer spirometry and more respiratory symptoms with being an ex-smoker in a cohort of ever-smokers in a population-based study in Kazakhstan. Methods: We first enrolled 5058 subjects, of whom 1769 were classified as ever-smokers (63% current a...
D. Vinnikov, I. Mukatova, Zh. Dairuly et al.· Journal of Clinical Medicine· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.