Skip to content
Open access

A LoRa-Based Wireless Sensor Network for Urban Water Quality Monitoring with Real-Time Machine Learning and Energy Analysis

Sep 2026 · Italian National Conference on Sensors · Vol 26, pp. 6159 · 0 citations · 47 references
Medicine

TL;DR

The results show that machine learning can be useful for reconstructing individual missing or invalid UV measurements when the corresponding optical measurements are available, and show that further experiments with more independent sessions and longer field deployments are needed.

Abstract

This paper presents a LoRa-based system for real-time urban water quality monitoring. The proposed platform integrates several sensors, including ultraviolet (UV), infrared (IR), red-green-blue (RGB), pH, turbidity, and temperature sensors, to monitor different water quality parameters. A total of 1443 sensor records were collected during the experiments. Among these records, 75 UV measurements, corresponding to approximately 5.2% of the dataset, were missing or invalid while the Red, Green, and Blue (RGB) and IR measurements were available. Several regression and machine learning models were evaluated to reconstruct these UV values. Multiple Linear Regression showed limited performance in the initial random train–test evaluation (R2 = 0.12), while second-order Polynomial Regression achieved a considerably higher R2 of 0.963. Support Vector Regression (SVR), k-Nearest Neighbors (KNN), Multi-Layer Perceptron (MLP), and Random Forest (RF) were also evaluated. Random Forest obtained the highest R2 in the random train–test evaluation (R2 = 0.991). However, the results were less consistent when the models were evaluated using Leave-One-Session-Out (LOSO) validation. In this evaluation, KNN obtained the lowest mean absolute error (MAE) and root mean squared error (RMSE), while the mean R2 values were negative for all evaluated models, showing limited generalization between experimental sessions. The possible energy benefit of UV reconstruction was also estimated. Based on an active power of 2.995 W and an acquisition time of 10 s, avoiding 75 additional acquisition cycles would correspond to approximately 0.624 Wh of acquisition energy, or 4.94% under the assumptions used in the energy analysis. These results show that machine learning can be useful for reconstructing individual missing or invalid UV measurements when the corresponding optical measurements are available. At the same time, the differences observed between experimental sessions show that further experiments with more independent sessions and longer field deployments are needed.

Read PDF

Similar papers

Open access Sep 2026

Virtual Sensing of Equivalent Black Carbon in the Context of Urban Automatic Monitoring Sensor Networks

Black carbon (BC) is an important urban air pollutant of emerging concern with documented health and climate effects, yet direct BC measurements remain unavailable at the majority of automatic monitoring stations in typical urban sensor networks. Virtual sensing has been recently proposed as a complementary approach, u...

M. Davidović, M. Davidović, D. Stojanović et al. · 0 citations
2026

Water quality monitoring using remote sensing and PCA-enhanced machine learning models

Following PCA-based dimensionality reduction, SVM maintained optimal classification performance, Random Forest retained strong predictive capability with minimal accuracy reduction, while Decision Tree performance declined, indicating greater sensitivity to reduced feature representation.

M. Oke, Atiku Shindawa · 0 citations
Open access Sep 2026

Real-Time Pond Water Quality Monitoring Device Design Using Hybrid Wireless Local Area Network and Cellular Technology

Climate change has increased environmental uncertainty, posing significant challenges to aquaculture sustainability in Indonesia, a coastal country where fishery resources play a vital role in food security and livelihoods. Despite high fish demand, pond productivity continues to decline due to suboptimal water quality...

A. Hana, H. P. Tjahyaningtijas, B. Suprianto et al. · 0 citations
Open access Oct 2026

AI and IoT-Based Water Quality Early Warning System

Water quality monitoring is important for identifying changes in water conditions and providing timely warnings when unusual measurements occur. Conventional laboratory testing provides accurate results but is not suitable for continuous real-time monitoring. This project proposes an AI- and IoT-based Water Quality Ear...

Atharva Aminbhavi, Yash Nagrale, Sandhya Jaiswal et al. · 0 citations
Open access Oct 2026

UAV integrated IoT sensing platform for sustainable air quality monitoring and real time AQI estimation

A drone-based air quality monitoring platform with IoT-enabled sensors integrated into it that provides a scalable proof-of-concept foundation that can be adapted for mobile micro-climate air quality monitoring across diverse urban and industrial topographies.

A. Bongale, Satish Kumar, C. H. Kumar et al. · 0 citations
Open access Oct 2026

Self-Adaptive Edge-Intelligent IoT Framework for Real-Time Water Quality Monitoring and Predictive Control

A research framework is proposed based on an intelligent edge-IoT architecture for real-time monitoring and assessment of water quality parameters that performs better than recent methods in classification accuracy and prediction error.

H. H. Qasim, Ahmed Hameed Majeed, Samar A. Al-Khafaji et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.