Skip to content
Open access

ACM for segmenting intensity inhomogeneity images corrupted by a mixture of AGMG noise

Oct 2026 · Bulletin of Electrical Engineering and Informatics · Vol 15, pp. 4068-4083 · 0 citations · 47 references

TL;DR

This is the first study to formulate an ACM for segmenting intensity inhomogeneity images corrupted by AGMG noise, and the proposed model proves significantly more effective for the segmentation of images degraded by intensity inhomogeneity and mixed AGMG noise.

Abstract

In practice, active contour models (ACMs) are effective in segmenting images, which are mostly applied in computer vision and medical imaging. However, the result may be challenged when the images contain noise and intensity inhomogeneity. Images are commonly deteriorated by a mixture of noise involving additive Gaussian and multiplicative Gamma (AGMG). To the best of our knowledge, this is the first study to formulate an ACM for segmenting intensity inhomogeneity images corrupted by AGMG noise. Our proposed mathematical model was developed using a combination of dual denoising terms to recover the noisy image and Laplacian of Gaussian (LoG) terms to smooth the targeted object. The model is solved using calculus of variations and finite difference methods. The performance of the suggested model for segmenting images was evaluated in MATLAB software and compared with current models using low and severe AGMG noise levels. Quantitative evaluations demonstrated that the proposed model outperformed existing models, achieving an average Jaccard similarity coefficient (JSC) improvement of roughly 2.5% and a 16.00% reduction in average relative error. Consequently, the proposed model proves significantly more effective for the segmentation of images degraded by intensity inhomogeneity and mixed AGMG noise.

Read PDF

Similar papers

Preprint Sep 2026

Poisson Image Denoising Using Minimax Concave and Reweighted $\ell_1$ Penalties: Nonblind and Blind Approaches

Images are important tools in various sciences. Despite the development of photo-taking tools, creating clear and image without noise remains challenging in practice. In particular, Poisson noise has an effect on medical and astronomical images, and reduces their quality. Additionally, blur is another factor that has a...

R. Parvaz · 0 citations
Open access Aug 2026

An Adaptive Detail Preserving Modified Progressive Pca Thresholding Based Image Denoising

An adaptive cluster-wise progressive denoising algorithm for maintaining detail in medical images that outperforms existing denoising methods in terms of noise suppression while conserving critical anatomical characteristics.

N. Anilkumar, S. Radhakrishnan, Shaik Syed Basha et al. · 0 citations
Aug 2026

A retinex-based hybrid-order total variation segmentation model for inhomogeneous image

A novel image segmentation model that integrates Retinex theory within a hybrid-order total variation framework is proposed that effectively mitigates staircase artifacts and retains structural details, resulting in more natural image restorations and improved segmentation accuracy.

Yuan Wang, Yuan Liu, Z. Pang · 0 citations
Open access Sep 2026

Prior Information-Assisted Intensity Inhomogeneity Correction Within a Fuzzy Clustering Framework

The method of utilizing available prior information in the popular FCM algorithm and assesses its benefits in estimating the intensity inhomogeneities and segmenting human brain MRI volumes is studied in this paper. The intensity inhomogeneities in medical images are associated with the acquisition sequences and imperf...

Unknown authors · 0 citations
Open access Sep 2026

Fuzzy Adaptive Loss Based on Quality and Region Weighting for Medical Image Segmentation

In medical image segmentation, models are often trained on data influenced by uncertainty, including poor image quality, unclear anatomical structures, and inconsistent annotations. These issues frequently lead to unstable optimization and biased predictions. We addressed these challenges in the context of drug-ind...

Shang-Lin Chung, Pei-Chen Huang, Yun-Ting Lee et al. · 0 citations
Review Open access Sep 2026

Limits of CNR and MSE in medical image quality.

Purpose Contrast-to-noise ratio (CNR) and mean-squared error (MSE) are often treated as compact surrogates for image quality. The purpose of this tutorial is to revisit why these scalar summaries are incomplete for detection and decision tasks unless the task, ensemble, and observer that make them meaningful are stated...

Matthew A. Kupinski · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.