DLD-enhanced ULD-CT showed diagnostic accuracy and sufficiency similar to full-dose CT for pelvic and hip fracture detection, though full-dose CT was rated higher in perceived image quality and diagnostic confidence and outperformed denoised low-dose CT numerically in hard cases.
Abstract
Objective: To evaluate the feasibility of simulated ultra-low-dose CT (ULD-CT) enhanced with deep learning denoising (DLD) for detecting pelvic and hip fractures. Method: This Institutional Review Board-approved retrospective study was performed at a multisite, single academic institution between October 2020 and May 2021, including 30 full-dose CT (CTfull) exams of acute pelvic and hip trauma (10 normal, 10 “easy,” 10 “hard” cases by fracture conspicuity). Simulated low-dose CT images at 10% (CT10sim) and 5% (CT5sim) radiation dose were generated using a noise model-based algorithm and reconstructed from full-dose CT datasets. A commercial deep learning denoising algorithm enhanced these images, resulting in denoised low-dose CTs (CT10dld and CT5dld) for evaluation. The 90 resulting CT cases were reviewed independently for diagnostic accuracy, confidence, sufficiency, and imaging quality. Result: Diagnostic accuracy was similar across CT modalities overall (CTfull 80.8% [72.9, 86.9]; CT10dld 78.3% [70.1, 84.8]; CT5dld 77.5% [69.2, 84.1]) and within the easy and normal strata; in hard cases, accuracy was numerically lower for CT10dld (45.0%) and CT5dld (42.5%) than for CTfull (57.5%). Diagnostic sufficiency was similarly high across modalities (CTfull 91.7%, CT10dld 87.5%, CT5dld 88.3%). CT full was rated highest in perceived image quality across all strata (mean 4.21 ± 0.83 overall vs. 3.47 ± 0.97 for CT10dld and 3.23 ± 0.98 for CT5dld) and in diagnostic confidence (mean 4.61 ± 0.63 vs. 4.45 ± 0.71 and 4.41 ± 0.72, respectively), though neither translated into a corresponding drop in diagnostic accuracy overall. Inter-reader agreement was highest between MSK radiologists, reaching substantial agreement on CT10dld (κ = 0.760) and CT5dld (κ = 0.672). Conclusions: DLD-enhanced ULD-CT showed diagnostic accuracy and sufficiency similar to full-dose CT for pelvic and hip fracture detection, at a fraction of the radiation dose, though full-dose CT was rated higher in perceived image quality and diagnostic confidence and outperformed denoised low-dose CT numerically in hard cases. Full-dose CT remains the preferred modality for complex and high-energy trauma, while denoised low-dose CT modalities represent a promising option for straightforward presentations where radiation minimization is a priority.
OBJECTIVE
To evaluate the diagnostic accuracy of low-dose (LD) and ultra-low-dose (ULD) computed tomography (CT) scan for stone identification in obese patients compared to conventional-dose CT.
METHODS
A review of patients undergoing CT scans for kidney or ureteral stones at two academic institutions was conducted....
Gabriel E. Martin, Kymora B. Scotland, Jason C. Smith et al.· Urology· 1 citation
Deep-learning-based reconstruction significantly enhances image quality and venous visualization in ultra-high-resolution CT venography compared with conventional iterative reconstruction, enabling detailed depiction of small venous structures.
Sebastian Steinmetz, Anna-Luisa Grebe, M. Kondova et al.· Clinical Neuroradiology· 0 citations
RATIONALE AND OBJECTIVES
Deep learning-based high-resolution computed tomography (CT) of the lung parenchyma has not been directly compared with ultra-high-resolution CT (UHR-CT). We compared image quality between deep learning-based super-resolution CT and UHR-CT using identical cadaveric human lungs.
MATERIALS AND...
Midori Ueno, Masahiro Yanagawa, Akinori Hata et al.· Academic Radiology· 0 citations
LD PCCT serves as a radiation-sparing alternative for quantitative disease assessment, with total disease burden showing good agreement with the SD protocol, offering a radiation-sparing alternative without compromising CT-physiology correlation.
Zhen-Chen Zhu, Ke-Pei Xu, Yi-Yun Pang et al.· European Radiology· 0 citations
Optimize CT acquisition protocols reduced radiation dose while preserving the evaluated objective image quality metrics in the cranial, thoracic, and upper abdominal regions, and was identified as a candidate protocol for subsequent clinical and reader performance validation.
D. Kostova-Lefterova, F. Simeonov, D. Hitova-Topkarova et al.· Biomedical engineering and p...· 0 citations
PURPOSE
Deep learning reconstruction may enable substantial radiation dose reduction in ultra-high-resolution (UHR) temporal bone CT, but its performance across clinically relevant dose levels remains insufficiently defined. This study evaluated vendor-specific deep learning reconstruction (DLR) compared with hybrid it...
Lavinia A. Brockstedt, Sebastian Altmann, Suam Kim et al.· Clinical Neuroradiology· 0 citations