Skip to content
Review

Efficient Computing for Medical Image Acquisition and Reconstruction

Jul 2026 · 0 citations
Engineering Computer Science Physics Mathematics

TL;DR

This chapter presents a unified computational perspective on medical image acquisition and reconstruction across CT, MRI, PET, and SPECT, and examines efficient computing considerations, including optimization algorithms, physics-aware forward operators, memory-efficient implementations, and parallel computing strategies.

Abstract

Medical imaging systems such as CT, MRI, PET, and SPECT do not directly acquire images. Instead, they measure physical signals that encode anatomical or physiological information, and image reconstruction recovers the underlying image by solving an inverse problem. Although these imaging modalities are governed by different imaging physics, they share a common computational framework that naturally connects medical physics, linear algebra, probability, numerical optimization, and efficient computing. As medical imaging systems acquire increasingly large and higher-dimensional datasets, image reconstruction has become one of the primary computational bottlenecks in modern medical imaging. Advanced reconstruction methods, including analytical reconstruction, iterative optimization, and statistical model-based reconstruction, substantially improve image quality while reducing radiation dose or scan time, but at significantly increased computational cost. Efficient computing has therefore become essential for achieving clinically practical reconstruction times. This chapter presents a unified computational perspective on medical image acquisition and reconstruction across CT, MRI, PET, and SPECT. It first reviews the imaging physics and data acquisition process for each modality and derives a generalized mathematical framework for image reconstruction. Building on this framework, the chapter discusses analytical, iterative, and statistical reconstruction methods together with their computational characteristics. Finally, it examines efficient computing considerations, including optimization algorithms, physics-aware forward operators, memory-efficient implementations, and parallel computing strategies. Together, these topics demonstrate how the integration of imaging physics, mathematical modeling, and efficient computing enables accurate and scalable medical image reconstruction.

View source

Similar papers

Conference Jul 2026

Research on kernel reconstruction methods for all-digital PET image reconstruction

Positron Emission Tomography (PET) is an advanced medical imaging technique widely used in clinical diagnosis and medical research. As an upgraded version of the traditional PET system, the all-digital PET system has significant hardware advantages. Its core strength is that it can provide accurate and complete single-event information, thereby enabling convenient filtering of data from different energy windows and laying a foundation for high-quality imaging. However, traditional PET image reconstruction algorithms have obvious limitations and struggle to achieve a balanced optimization between noise and contrast. To address this issue, the Kernel Expectation Maximization (KEM) algorithm has been proposed, inspired by kernel methods in machine learning, which can effectively overcome this technical challenge. Therefore, conducting research on the KEM algorithm based on the all-digital PET system is of great significance for fully exploiting the hardware advantages of the system and further improving PET imaging quality. This paper investigates the implementation of kernel reconstruction methods in the all-digital PET system, focusing on their performance under multiple energy windows and various scan durations, and compares the differences among the Ordered Subsets Expectation Maximization (OSEM) algorithm, the KEM algorithm, and the KEM algorithm with a quadratic penalty term. Simulation results demonstrate that in two typical scenarios of all-digital PET—different energy windows and different scan durations—adopting the KEM algorithm and the KEM algorithm with a quadratic penalty term effectively optimizes key indicators such as the voxel standard deviation (STD) and contrast recovery coefficient (CRC) in the region of interest (ROI), and significantly improves the quality of reconstructed images. The results are expected to provide technical ideas and practical references for the innovative application of all-digital PET in low-count imaging scenarios.

Junpeng Hu, Peng Xiao · 0 citations
Preprint Aug 2026

Toward a Foundation Plug-and-Play Prior for Computed Tomography Reconstruction via a Multimodal Diffusion Model

This work investigates whether a single diffusion model trained across several imaging domains can instead serve as a prior for many CT problems simultaneously, and proposes a frozen model that out-performs analytic reconstructions in all three cases.

Haley Duba-Sullivan, Patxi Fernandez-Zelaia, Obaidullah Rahman et al. · 0 citations
Review Open access Aug 2026

A Comprehensive Review of Multimodal Medical Image Fusion: Techniques, Evaluation, and Future Directions

This review provides a comprehensive overview of MMIF from theoretical and technical perspectives and presents current challenges and future development trends of MMIF, including robustness, clinical translation, and emerging multimodal learning paradigms.

Pengquan Han, Cui-Yin Liu, Cuiwei Wang · 0 citations
Open access Aug 2026

Guided MRI Reconstruction via Schrödinger Bridge.

I2SB-Inversion is proposed, a multi-contrast guided reconstruction framework based on the Schrödinger Bridge that achieves a a high acceleration factor of R=11.38 and consistently outperforms existing methods in both quantitative and qualitative evaluations.

Yue Wang, Yuanbiao Yang, Zhuo-xu Cui et al. · 0 citations
Review

Current Medical Imaging

Wanhui Zhou, Sihua Zhong, Jing Li et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.