Skip to content
Open access

Accuracy and clinical passive fit of reverse and standard scan body protocols for complete-arch implant-supported digital impressions: An in vitro study.

Sep 2026 · Journal of Prosthodontics · 0 citations · 27 references
Medicine

TL;DR

Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.

Abstract

Purpose

The purpose of this in vitro study was to compare the reverse scan body (RSB) and standard scan body (SCB) protocols for complete-arch implant-supported digital impressions with respect to root mean square (RMS), linear deviation, and angular deviation values, as well as clinical passive fit.

Materials And Methods

Configurations with four and six implants were created on edentulous maxillary and mandibular casts. Digital impressions were obtained with an intraoral scanner using the standard and RSB protocols (10 scans per subgroup; 80 datasets total) and superimposed onto reference datasets acquired with a laboratory scanner. RMS, linear, and angular deviation values were calculated. Clinical passive fit of cobalt-chromium verification jigs fabricated from digital data was evaluated by visual inspection, screw-resistance test, and radiographic assessment.

Results

Total RMS values did not differ significantly between the standard and RSB protocols (0.0384 ± 0.0017 vs. 0.0395 ± 0.0012 mm; p = 0.530), although the scan protocol × jaw interaction was significant (p = 0.001). In four-implant casts, the RSB protocol demonstrated significantly lower linear deviation than the SCB protocol (0.0618 vs. 0.0951 mm; p < 0.001); in six-implant casts, no main effect of protocol was found, although several interactions were significant. Angular deviation findings were configuration-dependent. Clinical passive fit was acceptable in 95% of verification jigs fabricated with the RSB protocol and 90% of verification jigs fabricated with the SCB protocol.

Conclusions

Within the limitations of this in vitro study, the RSB protocol demonstrated accuracy comparable to the SCB protocol, with more stable implant position transfer in four-implant configurations and a high clinical passive fit rate, supporting its use as a reliable alternative in complete-arch digital implant workflows.

Read PDF

Similar papers

#software testing Open access Oct 2026

Clinical Accuracy of Complete Arch Implant Scans Recorded by Using a Customized Metallic Ring-Based Calibrated Framework: An In Vivo Study.

AIM To evaluate and compare the positional accuracy of complete arch intraoral digital implant scans obtained using a conventional scan body protocol and a customized metallic ring-based calibrated framework. MATERIALS AND METHODS A completely edentulous arch restored with six implants was scanned using two complete...

Miguel Gómez-Polo, Solange Vasquez-Ramos, Marta Revilla-León et al. · 0 citations
Sep 2026

The accuracy of reverse scan body technique for capturing full-arch digital implant impressions: An in vitro study.

The RSB technique was inferior to the desktop scan in terms of digital impression and definitive prostheses accuracy, however, the RSB technique produced zirconia prostheses within the clinically acceptable deviation value of 0.15 mm.

Ahmed Elsayyad, C. Wyatt, Ross Bryant et al. · 0 citations
Open access Sep 2026

Model-free digital-correction workflow for multi-implant restorations: A clinical proof-of-concept study.

PURPOSE This clinical proof-of-concept study evaluates the feasibility and accuracy of a digital workflow for fabricating and correcting implant-supported restorations of multiple dental implants in an edentulous maxilla using intraoral scanning and reverse-scan bodies. METHODS An intraoral scan (IOS) was performed u...

A. Kernen-Gintaute, M. Akulauskas, F. Kernen et al. · 0 citations
#software testing Open access Sep 2026

Accuracy of Direct Intraoral Versus Reverse Scanning for Abutment-Level Implant Impressions: an In Vitro Study

This study indicates that direct intraoral scanning provides superior accuracy compared with RSTs, particularly in the posterior regions, whereas putty-only impressions exhibited substantially greater relative deviations, particularly in the posterior regions.

Sumit Deshpande, Diksha Rajkumar Kasnale, Konark N. Patil et al. · 0 citations
#software testing Open access Sep 2026

Influence of arch form on the accuracy of digital workflow in all-on-four implant rehabilitation cases (an in vitro study)

Variations in arch form may influence the accuracy of digital impressions for implant-retained fixed dental prostheses. Differences in arch width, curvature, and span length can affect scanning continuity and data stitching, potentially impacting trueness and precision during full-arch acquisition. However, the extent...

M. S. Torky, Rewaa G. AboElhassan, Amir S. Azer · 0 citations
Aug 2026

In Vivo Assessment of Complete-Arch Implant Impressions Using a Clinical Seating Score: A Proof-of-Principle Case Report.

The CSS may potentially provide a simple and standardized chairside method for evaluating the passive seating of complete-arch implant frameworks and help clinicians identify clinically relevant misfits before delivery of the definitive prosthesis and support more predictable decision-making during framework verificati...

Francesco Mintrone, F. Ferri, Rostyslav Havryltsiv et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.