TL;DR

SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment, however, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.

Abstract

Aim

To evaluate three-month visual and refractive outcomes after small incision lenticule extraction (SMILE) Pro with the VISUMAX 800 femtosecond laser for myopic astigmatism correction and to compare results with previously reported VISUMAX 800 and VisuMax 500 outcomes.

Methods

Retrospective, observational clinical study. Records of 64 patients (128 eyes) who underwent SMILE Pro using the VISUMAX 800 laser (Carl Zeiss Meditec AG, Jena, Germany) between June and November 2024 were reviewed. Preoperative and 3-month postoperative data were analyzed in eyes with corrected distance visual acuity (CDVA) of 1.0 or better, including spherical equivalent (SE), refractive astigmatism, and vector analysis. Patients were classified into low (≤1.50 D) and high (>1.50 D) astigmatism subgroups.

Results

The mean age of 64 patients (128 eyes) was 26.10±4.25y (19-36y). Attempted and achieved SE were strongly correlated (r=0.97, P<0.001). At 3mo, 36.7% and 87.5% of eyes were within ±0.50 and ±1.00 D of target refraction, respectively. Mean residual astigmatism was -0.56±0.27 D, lower in the low-astigmatism group (-0.39±0.23 D) than in the high group (-0.72±0.21 D; P<0.001). The mean absolute astigmatic angle of error was 4.47°±4.68°, with 97.6% ≤15°. No intraoperative or postoperative complications occurred.

Conclusion

SMILE Pro using the VISUMAX 800 femtosecond laser provides safe and predictable correction of myopic astigmatism with good axis alignment. However, the observed undercorrection in higher cylinders suggests that further optimization of astigmatic nomograms may improve refractive accuracy.

Read PDF

Similar papers

Open access Jul 2026

Refractive and Vector Outcomes of SMILE Pro with the VISUMAX 800 for High Astigmatism

SMILE Pro performed with the VISUMAX 800 provided favorable early 3-month refractive and astigmatic vector outcomes with a satisfactory safety profile in eyes with high astigmatism, evaluated up to 3 months postoperatively.

L. Tran, T. N. Tran, H. Cung et al. · 0 citations
Open access Jul 2026

Comparative Vector Analysis of Astigmatic Changes After Small-incision Lenticule Extraction versus Femtosecond Laser In -situ Keratomileusis

Abstract Purpose To compare thevisual outcomes of small-incision lenticule extraction (SMILE) versus femtosecond laser in-situ keratomileusis (FS-LASIK) in eyes with myopia and high astigmatism. Methods This retrospective study was conducted at a tertiary eye hospital between January 2021 and December 2022. Data were collected from individuals with myopia up to - 10.00 diopters (D) and cylinder ≥ 2.50 D who underwent SMILE (VisuMax 500) or FS-LASIK (MEL 90) and completed a 3-month postoperative follow-up. Results A total of 170 eyes of 123 patients were included: 83 eyes (60 patients) underwent SMILE, and 87 eyes (63 patients) underwent FS-LASIK. The preoperative cylindrical refractive error was - 3.01 ± 0.61 D in the SMILE group and - 3.09 ± 0.66 D in the FS-LASIK group. At 3 months, there was no statistically significant difference in uncorrected visual acuity (UCVA) or manifest refraction spherical equivalent (SEQ) between the two groups (P = 0.26 and P = 0.88, respectively). In the SMILE group, 90.4% of eyes achieved an uncorrected distance visual acuity (UDVA) of 20/20 or better compared to 98.77% with a preoperative corrected distance visual acuity (CDVA) of 20/20 or better. In the FS-LASIK group, 80.46% of eyes achieved a UDVA of 20/20 or better compared to 94.25% with a preoperative CDVA of 20/20 or better. Moreover, 95.1% of eyes in the SMILE group and 94.3% in the FS-LASIK group were within ± 0.50 D. Vector analysis showed comparable results between the two groups in terms of target-induced astigmatism (P = 0.559), difference vector (P = 0.155), index of success (P = 0.091), and angle of error (P = 0.89). The surgically induced astigmatism and correction index were significantly lower in the SMILE group (P < 0.01), whereas the absolute magnitude of error was higher in the SMILE group (P = 0.02). Conclusion SMILE and FS-LASIK have comparable efficacy, predictability, and safety in correcting myopia associated with high astigmatism ( ≥ 2.50 D).

Mai Hong Phan, Luong Minh Huynh, S. K. Foo · 0 citations
Open access Aug 2026

Safety and Efficacy of Keratorefractive Lenticule Extraction (KLEx) for High Myopia with the CLEAR Platform

Objectives: To assess the safety and efficacy of Keratorefractive Lenticule Extraction (KLEx) in patients with myopia ≥ 5 diopters (D). Methods: Retrospective study of KLEx procedures performed at Siena Eye Laser (Poggibonsi, Italy) with the CLEAR platform of the Ziemer Z8 femtosecond laser. Results: We included 137 eyes of 85 patients; mean age was 33.8 ± 8.3 years. Assessment at baseline showed a mean myopic error of −7.3 ± 1.4 D, a mean astigmatic error of 1.1 ± 0.8 D, and a mean spherical equivalent (SE) of −7.8 ± 1.6 D. Preoperative corrected distance visual acuity (CDVA) was 0.0 logMAR or better in all eyes. Mean corneal thickness was 510.0 ± 26.9 µm. At post-operative day 1 (POD1) uncorrected distance visual acuity (UDVA) was 0.1 ± 0.1 logMAR, with a mean residual SEQ of 0.1 ± 0.8 D. At 6 months follow-up, mean UDVA significantly increased to 0.0 ± 0.0 logMAR (p < 0.001), with a mean residual SE of −0.12 ± 0.7 D (p > 0.05 compared to POD1). At 24 months, the mean UDVA remained stable at 0.0 ± 0.0 logMAR, with a mean residual SE of −0.1 ± 0.4 D as manifest refraction (all p > 0.05 compared to 6 months). At 6 months and 2 years, the observed residual stromal bed (RSB) was 30 microns thicker than the RSB calculated by the Ziemer LDV Z8 software 2022. The difference between predicted (POZ) and effective (EOZ) optical zone correlated with the degree of myopia corrected (r = 0.6, p < 0.001). The difference between POZ and EOZ inversely correlated with astigmatic correction (r = −0.5, p < 0.001). Conclusions: In patients with high myopia, CLEAR showed good predictability and efficacy. Both UDVA and SE improved during the first 6 months, and remained stable at 2 years. The effective RSB was thicker than expected, and patients with high astigmatism achieved a larger EOZ.

Matteo Posarelli, Lorenzo Azzaro, Stefania V. Fields et al. · 0 citations
Open access Jul 2026

Early Visual, Refractive, and Astigmatism Vector Outcomes of StreamLight Trans-PRK for High Astigmatism (≥ 2.00 D)

Objective To report the early refractive, visual, and astigmatic-vector outcomes of single-step StreamLight™ transepithelial photorefractive keratectomy (Trans-PRK) on the WaveLight EX500 platform in eyes with high preoperative astigmatism (≥ 2.00 dioptres, D). Methods Single-centre cohort study of 171 consecutive eyes of 107 patients (mean age 27.87 ± 6.56 years; 37.4% female) treated by a single surgeon. Astigmatic outcomes were analyzed by the Alpins method at the corneal plane. A subset of 57 eyes with a mean follow-up of 10.3 ± 7.4 months underwent stability sub-analysis. Results Mean preoperative cylinder was 3.29 ± 0.81 D and mean spherical equivalent (SE) was −2.73 ± 2.56 D. At one month, mean UDVA was 0.05 ± 0.09 logMAR, mean residual cylinder was 0.65 ± 0.44 D, and mean SE was −0.22 ± 0.47 D. SE was within ±0.50 D of intended in 71.3% of eyes; cylinder was ≤ 0.50 D in 53.2%. Mean efficacy and safety indices were 1.04 ± 0.22 and 1.10 ± 0.22, respectively, with no eye losing two or more lines of CDVA. Vector analysis yielded a correction index of 1.09 ± 0.16, an index of success of 0.21 ± 0.14, and 99% of eyes within ±15° of the intended axis. Stability sub-analysis showed minimal change in SE and an unchanged cylinder between 1 month and a mean follow-up of 10.3 ± 7.4 months (SE −0.14 to −0.07 D). Discussion Trans-PRK delivered good early visual, refractive, and astigmatic vector outcomes. Axis precision was high with a mean angle of error of −0.81 ± 5.32°, 80% of eyes within ±5°, and 99% within ±15° of the intended axis. Interpretation of vectorial results is subject to the specificity of the 1-month post-Trans-PRK central epithelial thickness (CET decreases in the first week, returns to baseline at 1 month, and progressively increases up to 6 months). Conclusions Single-step StreamLight™ Trans-PRK on the WaveLight EX500 platform achieves favorable early refractive, visual, and vector-analytic outcomes in eyes with high preoperative astigmatism, with corneal-plane vector parameters that compare favorably with those reported in the published Trans-PRK literature.

Silvia Victoria Prodescu, Paul Filip Curcă, C. Tătaru et al. · 0 citations
Aug 2026

[Visual outcomes and satisfaction-related factors after laser blended vision surgery for myopia with presbyopia].

LBV surgery provided favorable UNVA and UDVA and good refractive predictability, with a high level of spectacle independence and overall satisfaction in patients with myopia and presbyopia, suggesting that preoperative assessment of the ocular surface status and accommodative function may be useful for patient selection and perioperative management.

Y. Y. Ma, W. H. Lin, L. L. Xie et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.