Development and evaluation of an anatomically guided system for ultrasound image acquisition in trauma assessment

Jul 2026 · Journal of Medical Imaging · Vol 13, pp. 045001 - 045001 · 0 citations · 33 references
Medicine Engineering

TL;DR

These results demonstrate the feasibility of anatomically informed MR guidance to support ultrasound acquisition by novice users and highlight its potential for trauma diagnostics in resource-limited or austere environments.

Abstract

Abstract. Purpose Medical care in battlefield and austere environments may require minimally trained personnel to perform complex diagnostic procedures such as ultrasound. We present a mixed reality (MR) guidance system that uses predictive anatomical modeling to assist novice operators in acquiring the extended Focused Assessment with Sonography in Trauma (eFAST). Approach A morphable anatomical atlas of the torso was constructed from 180 CT scans using automated segmentation, deformable registration, and regression-based mapping between internal anatomy and external anthropometry. The atlas was integrated with a portable ultrasound system and an MR headset with probe tracking to provide subject-specific holographic guidance during scanning. System accuracy was validated using imaging phantoms and evaluated in a study involving 16 novice operators performing six-window eFAST examinations using both conventional ultrasound and MR guidance across four healthy volunteers. Ultrasound images were graded by an expert clinician, and operator workload was assessed using the NASA Task Load Index. Results Atlas performance showed high segmentation accuracy (Dice score 0.93±0.04) and in-atlas prediction errors below 10 mm using six anthropometric measures. Phantom testing demonstrated end-to-end image localization accuracy of 2.2±0.6  mm. MR guidance was associated with a nonsignificant increase in correct-window acquisition (48% to 60%) and a significant improvement in diagnostic sufficiency (13% to 25%) while reducing perceived cognitive workload. Conclusions These results demonstrate the feasibility of anatomically informed MR guidance to support ultrasound acquisition by novice users and highlight its potential for trauma diagnostics in resource-limited or austere environments.

Read PDF

Similar papers

Open access Oct 2026

Automatic Trajectory Planning from Preoperative MRI images Using the AI-Optimized RRT* Algorithm for Robotic Breast Ultrasound

Ultrasound imaging is the most widely used technique for detecting and diagnosing breast cancer, as it provides real-time images in a non-invasive and inexpensive manner. However, performing ultrasound examinations requires experienced and well-trained operators either for probe manipulation during acquisition or durin...

Ghizlane Akrramou, My Hachem el Yousfi Alaoui, Bassma Jioudi et al. · 0 citations
Open access Sep 2026

Multidimensional Quality Evaluation of Imaging Performance for Musculoskeletal Ultrasound Computed Tomography System

Core parameters of the Musculoskeletal Ultrasound Computed Tomography System (MUCTS), such as spatial resolution, slice thickness, and three-dimensional reconstruction volume error, directly determine imaging performance and clinical diagnostic accuracy. To objectively and systematically assess the imaging quality and...

Xiao-Xue Bai, Li Zhao, Pan Zhou et al. · 0 citations
Review Open access Oct 2026

Standardized Transducer Placement Representation for Improved Reviewability of Ultrasound Examinations

Abstract Demographic change is increasing the need for autonomous healthcare solutions. In ultrasound imaging, robotic systems offer strong potential for automating examinations. However, robotic ultrasound examinations separate image acquisition from image assessment, which are conventionally performed simultaneously...

Susann Kriebisch, Ralf Bruder, Georg Männel et al. · 0 citations
Open access Sep 2026

A Standardized Technique for Ultrasound–MRI Fusion Imaging of the Carotid Artery for Vascular Assessment

Purpose: To describe a reproducible ultrasound–magnetic resonance imaging(MRI) fusion imaging technique developed for quantitative assessment of carotid wall strain and plaque morphology. Methods: MRI volumes (Oblique T2 Cube) were imported into the Sequoia ultrasound system equipped with an electromagnetic tracking mo...

Maxwell J. Kiernan, Rashid Al Mukaddim, Yurim Lee et al. · 0 citations
Review Open access Sep 2026

User validation of an AI-assisted ultrasound guidance system for rapid vascular access.

The AI-GUIDE-LL enables rapid, accurate femoral vessel localization and needle insertion among novice clinicians, supporting feasibility for field-forward military and point-of-care civilian settings.

S. Prakash, Theodore T. Pierce, M. Waugh et al. · 0 citations
Open access Sep 2026

Real-time simulation of musculoskeletal ultrasound from cryosectional anatomy.

BACKGROUND AND OBJECTIVE Musculoskeletal ultrasound is widely used in clinical practice but remains highly operator-dependent, requiring training in probe manipulation and anatomical interpretation. Existing simulators commonly rely on pre-recorded scans, CT or MRI volumes, synthetic anatomical models, or generative ap...

Pablo Casanova-Salas, J. Gimeno, Inma García-Pereira et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.