TL;DR

The proposed CM-RED method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction.

Abstract

Diffusion models (DMs) have emerged as powerful generative priors for MRI reconstruction with promising results. Yet DM-based methods require extensive iterative refinement, limiting their practical deployment. Consistency models (CMs) provide a compelling alternative, aiming to map out the diffusion trajectory in a single pass, enabling faster generation. In this work, we propose CM-RED, a novel MRI reconstruction method that integrates a pretrained CM into the regularization by denoising (RED) scheme. Our method builds on accelerated proximal gradient RED (RED-APG), and further incorporates controlled noise injection during the update steps to enhance generative diversity and accelerate convergence. Extensive experiments on the fastMRI knee and brain datasets demonstrate that CM-RED achieves high-quality reconstructions across multiple anatomies, contrast weights, acceleration factors, and undersampling patterns, using only 4 network function evaluations (NFEs). The proposed method consistently outperforms existing DM- and CM-based approaches in both quantitative metrics and visual fidelity, and exhibits strong robustness to hyperparameter variations, highlighting CM-RED as an efficient and effective generative framework for accelerated MRI reconstruction. The source code and pretrained models are publicly available at https://github.com/MerveGulle/CM-RED.

View source

Similar papers

#artificial intelligence Preprint Aug 2026

Physics-Guided Flow Matching for CT Image Reconstruction

Experimental results across several CT inverse problem settings show that Flow Matching-based approaches consistently outperform diffusion-based methods in terms of PSNR, SSIM, and perceptual quality, while requiring fewer sampling steps.

Davide Evangelista · 0 citations
Open access Aug 2026

Guided MRI Reconstruction via Schrödinger Bridge.

I2SB-Inversion is proposed, a multi-contrast guided reconstruction framework based on the Schrödinger Bridge that achieves a a high acceleration factor of R=11.38 and consistently outperforms existing methods in both quantitative and qualitative evaluations.

Yue Wang, Yuanbiao Yang, Zhuo-xu Cui et al. · 0 citations
Jul 2026

A Bilevel Sensitivity-Corrected Reconstruction Framework with Deep Priors for Parallel MRI

A model-driven bilevel optimization framework that couples SENSE-based image reconstruction with SPIRiT-based k-space calibration through shared CSMs, and introduces a deep-prior-guided regularization strategy that preserves the structure of classical linear regularizers while adaptively learning spatially varying regularization weights from denoised intermediate reconstructions.

Weipeng Chen, Yan-Ran Li, Raymond H. Chan et al. · 0 citations
#machine learning Preprint Aug 2026

Primitive Representation Learning for Unsupervised Dynamic Contrast Enhanced MRI Reconstruction

This work proposes a multi-dimensional, primitive based framework for dynamic contrast-enhanced MRI reconstruction that disentangles the underlying anatomy, the dynamic contrast enhancement, and residual motion into separate temporal basis functions, thereby enabling a geometrical interpretation of the representation.

Veronika Spieker, Wenqi Huang, Cemre Ariyurek et al. · 0 citations
Open access Aug 2026

AI-based reconstruction from low-resolution acquisitions for diffusion MRI: evaluation of FOD similarity

MRI provides essential insights into tissue microstructure, and high angular resolution diffusion imaging (HARDI) enables detailed assessment of complex white matter architecture through fiber orientation distribution (FOD) analysis. However, HARDI requires high b-values and multiple diffusion directions, leading to reduced signal-to-noise ratio (SNR) and long scan times. Conventional zero-fill interpolation processing (ZIP) is widely used for super-resolution but is limited by edge blurring and artifacts. This study evaluated an AI-based reconstruction method, Precise IQ Engine (PIQE). Specifically, low-resolution diffusion data were reconstructed to standard resolution and compared with standard-resolution acquisitions. Ten healthy volunteers underwent HARDI at 3T, and FOD were estimated using constrained spherical deconvolution. Quantitative comparisons with reference data demonstrated that PIQE exhibited higher distributional similarity (lower Jensen–Shannon divergence) and directional agreement (higher angular correlation coefficient) compared with ZIP+Advanced Intelligent Clear-IQ Engine (AiCE), with statistically significant similarity observed. These findings indicate potential usefulness in advanced diffusion MRI applications.

Akihiro Kasahara, Yuichi Suzuki, Kazuki Endo et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.