Skip to content
Open access

Joint Reconstruction of Multiple b‐Values and Multiple Directions for Accelerating Diffusion Kurtosis Imaging

Jul 2026 · Magnetic Resonance in Medicine · Vol 96, pp. 2370 - 2380 · 0 citations · 48 references
Medicine

TL;DR

A novel model‐based reconstruction approach is proposed to accelerate iEPI DKI acquisition to enable higher resolution diffusion kurtosis imaging compared to single‐shot EPI.

Abstract

While multishot interleaved echo‐planar imaging (iEPI) enables higher resolution diffusion kurtosis imaging (DKI) compared to single‐shot EPI, its clinical application is hindered by the lengthy acquisition time. This study proposes a novel model‐based reconstruction approach to accelerate iEPI DKI acquisition.

Read PDF

Similar papers

Open access Aug 2026

Low‐dose CT imaging using a regularization‐enhanced efficient diffusion probabilistic model

Low‐dose CT (LDCT) imaging reduces patient radiation exposure but introduces elevated noise levels that degrade image quality and undermine downstream clinical tasks such as diagnosis and quantitative analysis. Existing denoising approaches often require extensive diffusion steps that impede real‑time clinical applicability.

Qiang Li, M. Safari, Shansong Wang et al. · 0 citations
Open access Jul 2026

“Two‐For‐One”: 4D Cardiac and Pulmonary MR Imaging From a Single Acquisition Using bSTAR

To generate 4D (3D+time) images of both the heart and lungs using a single volumetric radial free‐breathing bSSFP dual echo acquisition (bSTAR) with two image reconstructions within a single pipeline deployed inline at 0.55 and 1.5 T.

P. Daudé, Jordan Taylor, Joseph W. Plummer et al. · 0 citations
Jul 2026

Evaluation of Motion Correction on Myocardial [18F]F-AraG PET Uptake Using Data-Driven Respiratory Gating

[18F]F‐AraG (radio‐fluorinated 9‐β‐D‐arabinofuranosylguanine) is a PET radiotracer for imaging T‐cell activation with emerging applications in myocardial imaging. Cardiac PET is particularly susceptible to respiratory motion, which degrades spatial resolution and introduces regional variability in quantitative measurements.

Hannah Kim, Ryan Tang, Uttam M. Shrestha et al. · 0 citations
Open access Aug 2026

AI-based reconstruction from low-resolution acquisitions for diffusion MRI: evaluation of FOD similarity

MRI provides essential insights into tissue microstructure, and high angular resolution diffusion imaging (HARDI) enables detailed assessment of complex white matter architecture through fiber orientation distribution (FOD) analysis. However, HARDI requires high b-values and multiple diffusion directions, leading to reduced signal-to-noise ratio (SNR) and long scan times. Conventional zero-fill interpolation processing (ZIP) is widely used for super-resolution but is limited by edge blurring and artifacts. This study evaluated an AI-based reconstruction method, Precise IQ Engine (PIQE). Specifically, low-resolution diffusion data were reconstructed to standard resolution and compared with standard-resolution acquisitions. Ten healthy volunteers underwent HARDI at 3T, and FOD were estimated using constrained spherical deconvolution. Quantitative comparisons with reference data demonstrated that PIQE exhibited higher distributional similarity (lower Jensen–Shannon divergence) and directional agreement (higher angular correlation coefficient) compared with ZIP+Advanced Intelligent Clear-IQ Engine (AiCE), with statistically significant similarity observed. These findings indicate potential usefulness in advanced diffusion MRI applications.

Akihiro Kasahara, Yuichi Suzuki, Kazuki Endo et al. · 0 citations
Open access Jul 2026

Image Encoding With Blipped Gradients in an Echo Train

An MRI scanner was designed and built to encode k ‐space points in the spin echoes occurring between 180∘ pulses in an echo train by using blipped B0 gradient pulses applied just prior to those spin echoes.

L. Vidarsson, G. Sarty · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.