Skip to content

Vendor-independent Aortic Valve Calcium Scoring in Patients with Discordant Echocardiographic Criteria of Severe Aortic Stenosis.

Aug 2026 · Radiology: Cardiothoracic Imaging · Vol 8 4, pp. e250480 · 0 citations · 17 references
Medicine

TL;DR

A previously developed calibration tool, the vnAS, was validated and reclassified patients with discordant echocardiographic findings into the severe aortic stenosis group.

Abstract

Purpose To apply a vendor-neutral Agatston score (vnAS) for aortic valve calcification across multiple CT systems and to aortic stenosis severity classification. Materials and Methods Anthropomorphic phantoms with varying degrees of calcification were scanned using seven different CT systems and a reference electron-beam CT system to determine the vnAS. The vnAS was calculated using a regression model, whose performance was evaluated by both the coefficient of determination and analysis of variance. The vnAS was subsequently validated on a retrospective patient sample from eight international centers. Thresholds of severe aortic valve stenosis were defined as 1274 and 2065 AU for women and men, respectively. Results The Agatston scores from all CT systems were strongly correlated with that of the reference system (R2 > 0.932). On the basis of their echocardiographic findings, 183 of 831 (22.0%) patients (mean age ± SD, 77 years ± 10; 351 of 831 [42.2%] women) had discordant echocardiographic aortic valve stenosis findings. Among women with discordant results, the vnAS was higher than the traditional aortic valve calcium score (median, 1693 AU [IQR, 908-2513 AU] vs 1181 AU [IQR, 726-1964 AU], respectively; P < .001). Similar findings were observed for men (median, 2658 AU [IQR, 1894-3822 AU] vs 2056 AU [IQR, 1408-3056 AU], respectively; P < .001). Using the vnAS, 8.5% of women and 17.8% of men with discordant echocardiographic findings were reclassified into the severe aortic stenosis group. Conclusion A previously developed calibration tool, the vnAS, was validated and reclassified patients with discordant echocardiographic findings into the severe aortic stenosis group. Keywords: CT, Echocardiography, Percutaneous, Cardiac, Valves, Calcifications/Calculi, Technology Assessment, Vendor-neutral Agatston Score, Aortic Stenosis, Aortic Valve Calcification, Phantoms Supplemental material is available for this article. © RSNA, 2026 See also commentary by Jaltotage and Leipsic in this issue.

View source

Similar papers

Jul 2026

Journal of Community Hospital Internal Medicine Perspectives Journal of Community Hospital Internal Medicine Perspectives

CT-derived AVA demonstrates strong agreement with TTE and provides complementary information for severity assessment and risk stratification in patients with aortic stenosis, particularly in cases with discordant or borderline findings.

Shehroz Sultan, Neeraj Joshi, A. H. Awan et al. · 0 citations
Aug 2026

Diagnostic Value of Calcium Score Derived From Virtual Noncontrast, Non-ECG-gated Dual-energy CT as an Indicator of Severe Aortic Stenosis.

Aortic Valve Calcium Score obtained on VNC images from DECT examinations is a promising method for noninvasively differentiation between severe and nonsevere aortic stenosis, which could be potentially useful in patients who have undergone examinations for noncardiac indications.

Jakub Byczkowski, Gregorio Chierchia, G. Muscogiuri et al. · 0 citations
Open access Aug 2026

CT-based multi-threshold calcium scoring for aortic valve assessment: comparable predictive performance across HU thresholds in a pre-TAVI cohort.

Higher HU thresholds did not outperform conventional 130-HU scoring and showed only modest, comparable performance for within-severity hemodynamic stratification, and should be interpreted as complementary densitometric analyses rather than alternative diagnostic cut-offs.

Michael Welt, M. Alnees, Yazan Hamdan et al. · 0 citations
Open access Jul 2026

Artificial intelligence–based calcium scoring using 3D transesophageal echocardiography in aortic stenosis: a pilot study

AI-based calcium quantification using 3D TEE is feasible and correlates with CT-derived scores, and this radiation-free approach may provide a promising alternative for assessing aortic valve calcification.

P. Fazendas, R. Bairros, L. Elvas et al. · 0 citations
Open access Aug 2026

Agreement Between Transthoracic Echocardiography and Digital Subtraction Angiography for the Detection of Right Atrial Thrombus in Patients Undergoing Maintenance Hemodialysis: A Retrospective Cohort Study

TTE is recommended as the first-line CRAT screening tool for MHD patients and combined TTE and DSA use improves diagnostic yield, and regular targeted surveillance for high-risk individuals reduces CRAT incidence.

Fen Yu, Xiaomei Huang, Jing-Jing Liu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.