Rotor inter-turn short-circuit (ITSC) faults in synchronous generators introduce electromagnetic asymmetries that can lead to torque ripple, unbalanced magnetic pull, and progressive mechanical degradation. While most existing studies focus on binary classification and severe fault conditions, the assessment of incipient rotor ITSC severity using displacement-sensitive vibration measurements remains relatively underexplored. This paper proposes a vibration-based diagnostic framework for multi-class severity classification of rotor ITSC by integrating an eddy-current displacement sensor with physically motivated feature extraction. An 18-dimensional hybrid feature set is designed to characterize electromechanical modulations induced by rotor electromagnetic asymmetry. Using an XGBoost classifier with leave-one-out cross-validation, the proposed approach achieved 90.56% overall accuracy, including 99% recall for healthy operation and 87% recall for mild fault conditions. The results suggest that displacement-sensitive vibration analysis enables effective severity-aware diagnosis of rotor ITSC with minimal sensor requirements.
The problem of fault diagnosis in electrical motors has an important impact on the supervision of dynamic systems, and model-based methods are efficient tools for this purpose. In this regard, this work presents a novel method for detecting inter-turn short circuits (ITSCs) in the stator windings of permanent magnet sy...
David Marcos-Andrade, Francisco Beltrán-Carbajal, I. Rivas-Cambero et al.· Mathematics· 0 citations
The outcomes prove that the integrated technical framework (time-domain features + FR + SVM) provides zero false alarms and a balanced diagnostic system that combines computational speed with high precision.
H. Zaimen, T. Thelaidjia, Makhlouf Chouki et al.· International Journal of Ele...· 0 citations
Rotor faults are a prevalent failure mode in induction motors. In the stator current of induction motors, the fault characteristic frequency component is in close spectral proximity to the fundamental component, yet possesses an extremely low amplitude. This makes it prone to being overwhelmed by the leakage of the fun...
Wenbiao Hu, Zhaorui Lv· International Conference on...· 0 citations
This paper investigates the diagnosis of Inter-Turn Short-Circuit (ITSC) faults in Permanent Magnet Synchronous Machines (PMSM) under controlled experimental conditions. The study is based on stator current signals acquired for different speeds, load levels, and fault severities. Since time-domain waveforms under varia...
Y. Azzoug, M. Boukhnifer, R. Pusca· International Conference on...· 0 citations
Tank vibrations of a power transformer, originating primarily from winding vibration and core vibration through mechanical coupling and fluid–structure interaction, are regarded as essential carrier signals for assessing the integrity of the winding. To improve the diagnostic accuracy of winding condition, this paper p...
Bo Ren, Peidong Gao, Fenghua Wang et al.· Energies· 0 citations
Early and reliable diagnosis of inter-turn short-circuit (ITSC) faults is critical to maintaining the reliability, availability, and safe operation of doubly fed induction generators (DFIGs) used in wind energy conversion systems (WECSs). Incipient winding faults are particularly challenging to identify because their e...
M. Abid, S. Laribi, M'hamed Larbi et al.· Algorithms· 0 citations