Skip to content
Open access

Millimeter-Wave Radar Non-Contact Heart Rate Monitoring: A Cross-Platform Study Under Steady and Unsteady Conditions

2026 · IEEE Access · Vol 14, pp. 132045-132063 · 0 citations · 41 references

TL;DR

Overall, under controlled conditions and a fixed workflow, AWR2944EVM provides more stable heart rate estimation and may inform subsequent non-contact monitoring.

Abstract

As the demand for isolation care increases, clinical practice requires non-contact, low-interference, long-term vital sign monitoring. Remote photoplethysmography (rPPG), infrared thermography (IRT), and pyroelectric infrared sensors (PIR) have been used for vital sign measurement but are susceptible to occlusion and motion interference. In contrast, millimeter-wave (mmWave) radar is not limited by lighting and can detect chest micro-displacement through thin clothing, enabling non-contact heart rate monitoring. However, studies have examined single radar platforms under steady conditions, with limited cross-platform and post-exercise evaluation. Differences in carrier frequency and antenna configuration may affect phase noise, SNR, range resolution, affecting heart rate estimation. Under identical conditions and processing, IWR6843AOPEVM and AWR2944EVM are evaluated under steady and post-exercise unsteady conditions using electrocardiography (ECG) as reference. Because hardware and acquisition architectures differ, results reflect system-level rather than single-hardware effects. Measurements were performed with seated subjects at a 40 cm radar-to-chest distance, with synchronous mmWave and ECG acquisition. Both platforms extract echo time series from Range-Azimuth heatmaps using background estimation and range masking. Adaptive Band-Limited Filtering (ABP), Empirical Mode Decomposition (EMD), Robust Outlier Suppression (ROS), and Local Energy Normalization (LEN) are evaluated, with ROS $\to $ EMD used. MAEs were 6.89 and 21.22 bpm for IWR6843AOPEVM and 2.16 and 4.19 bpm for AWR2944EVM under steady and unsteady conditions, respectively. Absolute Percentage Error (APE), Bland-Altman, and Cumulative Distribution Function (CDF) analyses showed a more concentrated AWR2944EVM error distribution. Overall, under controlled conditions and a fixed workflow, AWR2944EVM provides more stable heart rate estimation and may inform subsequent non-contact monitoring.

Read PDF

Similar papers

Open access Oct 2026

Non-contact Beat-to-Beat Pulse Interval Estimation from Radial Artery Micro-Movements Using mmWave Radar

This study presents a novel contactless method for beat-to-beat pulse interval estimation using 24 GHz millimeter-wave radar detection of radial artery surface motion. The proposed system employs Doppler effect principles to detect physiological micro-movements, incorporating comprehensive signal processing including b...

Tiếp Trí Vương, Y. Hoàng, Tuyen Trong Nguyen et al. · 0 citations
Conference Sep 2026

Embedded Ultrasound Doppler Radar for Real-Time Sub-Millimeter Motion Sensing

Acoustic signals and ultrasound are common and effective methods to analyze system behavior and measure physical motion. This work presents a modular sensing system that utilizes continuous-wave ultrasound Doppler radar to detect sub-millimeter motion. The system architecture combines a directional ultrasound transduce...

Johannes Anderle, Volker Tenta, Patrick Schmitt et al. · 0 citations
Open access Sep 2026

Radar-Based Heart Rate Estimation Method Under Respiratory Harmonic Interference

A signal processing framework that addresses the challenge of accurate heart rate estimation through three integrated stages, providing a practical solution for reliable radar-based heart rate monitoring without requiring subject-specific calibration or specialized hardware modifications.

Di-Di Xu, Ying Li, Zi-Nan Wu et al. · 0 citations
Open access Sep 2026

Validation of a contactless radar system for continuous respiratory rate and heart rate monitoring in clinical and simulated use conditions

Continuous monitoring of respiratory rate (RR) and heart rate (HR) remains limited in post-acute and long-term care (PALTC) settings, where intermittent spot checks may delay detection of clinical deterioration. Contactless radar-based sensing offers an unobtrusive alternative suited to these environments. This study...

Piyush Sharma, Volodymyr Bondarenko, M. Denning et al. · 0 citations
Open access Sep 2026

DailyBeat: Reliable Cardiac Sensing Under Self-Induced Dynamic Interference Using mmWave Radar

Reliable cardiac monitoring in daily work environments could support applications such as stress assessment and mental workload tracking. Radar sensing provides a promising contactless solution by capturing subtle chest motion without requiring wearable devices. However, many existing methods assume quasi-static condit...

Zhao-Xin Chang, Pei Wang, Xu-Jun Ma et al. · 1 citation