Skip to content
Open access

How bone mis‐segmentation affects MRI‐based sCT dosimetry in head and neck radiotherapy: A CT‐referenced study

Aug 2026 · Journal of Applied Clinical Medical Physics · Vol 27 · 0 citations · 33 references
Medicine

TL;DR

The impact of bone segmentation on dosimetry is evaluated and the DA of the bone can be of interest if correctly segmented, but in the absence of certainty, an overestimation will lead to significant errors while an underestimation gives results close to the reference.

Abstract

Abstract Background Magnetic resonance imaging (MRI) is commonly used for head‐and‐neck (H&N) delineation in radiotherapy (RT) owing to the lack of contrast in computed tomography (CT) images. MRI‐based dosimetry is not yet fully developed for the H&N area due to the inter‐patient variability and the difficulty of accurately quantifying cortical bone based on MRI measure. Purpose Despite the difficulty of cortical bone segmentation with nearby air area, most papers in the literature show dosimetry results very close to the reference CT scan dosimetry. This study evaluated the impact of bone segmentation on dosimetry. Methods A home‐made phantom was used to evaluate the Hounsfield unit (HU) values of different tissue at diverse scanner energies. Different dosimetry plans were considered and compared with the reference CT‐based RT plan used for the treatment: CT images with cortical bone voxels assigned to the density of water and three based on MR images using a density assignment (DA) method for synthetic CT (sCT) generation with various bone attribution. Images from 24 patients were compared using mean absolute error (MAE). The generated dosimetry parameters were compared on the basis of dose–volume histogram values and 3%/3 mm gamma pass rates. Results Among the sCT, the best MAE were found for the DA sCT without bone. The mean of the median dose difference for the planning tumor volume (PTV) was less than 2% for all sCT. Mean gamma pass rate for the MR‐based sCTs were comparable. Conclusions The DA of the bone can be of interest if correctly segmented, but in the absence of certainty, an overestimation will lead to significant errors while an underestimation gives results close to the reference. The relevance of very precise sCT can be questioned if it requires too many resources and overlooks patients with artifacts.

Read PDF

Similar papers

Open access Oct 2026

Synthetic MRI from radiotherapy planning CT images for Head‐and‐Neck Cancer

Abstract Background Computed Tomography (CT) provides geometric accuracy and electron density information essential for radiotherapy planning; however, it offers limited soft‐tissue contrast. Magnetic Resonance Imaging (MRI) improves tumor visualization but introduces registration uncertainties when acquired separately...

P. Ramachandran, Akshay C. Dhargave, Catherine Jones et al. · 0 citations
Open access Sep 2026

Comparative evaluation of VoxelMorpand conventional deformable image registration algorithms for thoracic 4D‐CT in radiotherapy

Abstract Background Deformable image registration (DIR) is essential for thoracic four‐dimensional computed tomography (4D‐CT)‐based radiotherapy applications. Recently, deep learning‐based DIR methods such as VoxelMorph have been proposed; however, their performance relative to clinically used DIR algorithms remains u...

Mizuha Sakai, M. Nakao, H. Hirashima et al. · 0 citations
Open access Oct 2026

Evaluation of registration accuracy using short‐arc cone‐beam computed tomography for image‐guided radiotherapy in breast cancer

Abstract Background Image‐guided radiotherapy (IGRT) using cone‐beam computed tomography (CBCT) enables highly accurate imaging registration; however, increased radiation exposure remains a concern. Recently, short‐arc CBCT (SA‐CBCT), which reduces projection data and reconstructs images, has become available. Although...

Shuhei Wada, M. Tominaga, M. Sasaki et al. · 0 citations
Open access Sep 2026

Feasibility of multi‐energy CT and fat fraction MRI for characterizing active bone marrow response to pelvic external beam radiation therapy

Abstract Background Pelvic external beam radiation therapy (EBRT), frequently exposes a substantial fraction of active bone marrow (ABM), leading to radiation‐induced marrow suppression and associated hematologic toxicity. Accurate delineation and quantitative assessment of ABM are therefore essential to enable marrow‐...

Carolyn A. Eckrich, K. Bradley, Bethany Anderson et al. · 0 citations
Open access Sep 2026

Application of synthetic computed tomography based on a deep learning model in pelvic radiotherapy planning: A feasibility study

Abstract Background While computed tomography (CT) remains an important imaging modality in radiotherapy planning, magnetic resonance imaging (MRI)‐only workflow, often realized via the generation of synthetic computed tomography (sCT), is desired due to superior soft‐tissue contrast and less susceptibility to registra...

Feng-Nian Lin, Jin-Yan Hu, Zhao-Zhe Li et al. · 0 citations
Open access Sep 2026

Evaluation of inter‐fractional anatomical variations due to compression belt placement reproducibility using MR‐guided radiotherapy treatment fraction images

Abstract Background Abdominal compression (AC) using a belt‐based system is widely employed in radiation therapy to limit respiration‐induced target motion for abdominal and hepatic malignancies. While AC has demonstrated efficacy in reducing intrafraction motion amplitude, the interfractional anatomical consequences o...

Olivia Shay, David Solis, Morgan Aire et al. · 1 citation

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.