Abstract

To improve the accuracy and noise robustness of conventional travelingwave- based cable fault location methods under severe noise conditions, a two-terminal travelingwave fault location method is proposed. The proposed method combines variational mode decomposition optimized using Improved Sand Cat Swarm Optimization (ISCSO-VMD) with the Novel Teager Energy Operator (NTEO). A phase-mode transformation is first applied to convert the three-phase signals into modal components and reduce the influence of interphase coupling. ISCSO-VMD is then employed to adaptively decompose and denoise the traveling-wave signals, thereby extracting fault-related highfrequency intrinsic mode functions. Subsequently, NTEO is applied to enhance the transient energy features of the initial traveling-wave front. Finally, the fault distance is calculated using a twoterminal traveling-wave time-difference model. The proposed method is validated using PSCAD/EMTDC simulations. Simulation results for different fault locations, fault resistances, fault inception angles, and noise levels demonstrate stable and accurate detection of the initial traveling-wave front. The relative location error does not exceed 0.43% across all simulated fault cases. In the comparative noise tests, the proposed method maintains more stable initial-wavefront detection than the wavelet-NTEO and EMD-NTEO methods. The improved performance is attributed to the complementary effects of adaptive VMD parameter optimization and transient energy enhancement. ISCSO-VMD suppresses noise and mitigates mode mixing, enabling reliable extraction of fault-related high-frequency components, while NTEO enhances the transient energy features of the initial traveling-wave front and facilitates its detection under low-SNR conditions. However, the practical performance of the proposed method still requires validation on field-installed cables, particularly with respect to cable joints, sheath cross-bonding, measurement bandwidth, propagation-velocity uncertainty, and time-synchronization errors. The proposed method achieves accurate and noise-robust two-terminal traveling-wave fault location by combining adaptive signal decomposition with transient energy enhancement. The results demonstrate its effectiveness under the investigated simulation conditions.

View source

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.