This paper presents a measurement-validated power quality assessment of a grid-connected wind farm in Jordan based on synchronized field measurements and validated simulation studies. The increasing penetration of large-scale wind farms into modern power systems introduces significant power quality challenges, particularly voltage instability, harmonic distortion, and compliance with low- and high-voltage ride-through (LVRT/HVRT) requirements under weak grid conditions. High-resolution voltage and current sensors installed at the Point of Common Coupling (PCC) were used to monitor key power quality parameters, including active power variation, total harmonic distortion (THD), voltage flicker, frequency deviation, crest factor, and voltage unbalance. The measured steady-state results indicate that the PCC voltage was maintained at approximately 1.0 p.u., the system frequency remained stable at 50 Hz, THD values were within IEEE 519-2022 limits, and flicker indices (Pst and Plt) satisfied EN 50 160 requirements. Sensor data were further utilized to validate the simulation model developed using power system simulation software. Dynamic system behavior was investigated under LVRT and HVRT conditions, including severe (0 p.u.) and moderate (0.4 p.u.) voltage sags, as well as 1.15 p.u. and 1.20 p.u. voltage swell scenarios, emphasizing the role of real-time PCC measurements in enabling fast static synchronous compensator (STATCOM) response for voltage regulation and reactive power support. The results demonstrate compliance with international standards and highlight the effectiveness of real-time power quality sensing in improving voltage stability and grid code compliance. This study provides utility-scale experimental evidence from a real 100 MW wind farm and demonstrates the practical value of integrating synchronized PCC measurements with STATCOM-based reactive power control to enhance grid reliability and renewable energy integration.
The quality of power in medium-voltage distribution grids has become increasingly challenging due to the growing penetration of variable renewable energy sources and the increasing presence of unbalanced loads. Variable distributed generation introduces generation ramps at the Point of Common Coupling (PCC), causing ra...
Igor S. Rodrigues, A. D. Espindola, Silvangela L. Barcelos et al.· Eletrônica de Potência· 0 citations
Grid voltage unbalance is one of the major issues affecting the power quality of modern distribution systems due to uneven load distribution, the integration of distributed energy resources, and grid disturbances. This condition may reduce the reactive power compensation performance and the DC-link voltage stability of...
Le Van Tung· 2026 International Ural Conf...· 0 citations
The increasing penetration of distributed renewable energy sources, particularly grid-connected photovoltaic (PV) systems, has introduced new challenges related to the quality and stability of electrical power in low-voltage distribution networks. Buildings equipped with distributed generation units often integrate bot...
S. Asenov, A. Chekichev· Journal of Physics, Conferen...· 1 citation
The operating performance of wind electric generators has considerable stress on the quality of electric power and reliability in the performance power systems [1]. Power quality issues such as voltage dip, harmonic distortion and reliability problems are main considerations in this work. The voltage distortion & react...
K.Prathibha, K.Madhavilatha· Journal of Science & Technol...· 0 citations
To reduce dependence on diesel-based power generation and associated carbon emissions, the Government of Timor-Leste has initiated the development of a 15 MWp on-grid solar photovoltaic (PV) power plant within the EDTL RAEOA operational area. While this initiative supports the national clean energy transition and risin...
Jose Alexandre Bana, Abraham Lomi, Widodo Pudji Muljanto et al.· Sinergi· 0 citations
The increasing penetration of converter-interfaced renewable energy sources poses significant challenges to power quality in modern microgrids, especially under nonlinear and unbalanced load conditions. Conventional virtual-impedance strategies can improve converter-grid interaction; however, the use of fixed parameter...
C. R. Jiménez Román, E. Hernández-Mayoral, M. Madrigal-Martínez et al.· Processes· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.