Taming foundation model with invariance-oriented pre-training for broad-spectrum EEG analysis across signal-level, brain-state, and brain-health tasks

Aug 2026 · 0 citations · 54 references
Computer Science

TL;DR

Objective ablations and representation analyses show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone, establishing invariance learning as a promising principle for building reusable EEG foundation models.

Abstract

Electroencephalography (EEG) is a widely used window into human brain function, but most EEG models remain tied to a one-dataset-one-model supervised paradigm. Recent EEG foundation models offer a route toward reusable representations, but most remain reconstruction-centered, assuming that EEG content predictable from local context is necessarily transferable neural information. Here we present INCEPT, an invariance-oriented EEG foundation model trained on over 11,000 hours of unlabelled clinical EEG. Rather than prioritizing signal recovery alone, INCEPT learns representation-level stability across correlated EEG observations, separating stable neural structure and essential subject-sensitive information from the nuisance variability that dominates scalp recordings while preserving subject-, state- and condition-discriminative information. We evaluate INCEPT on a broad-spectrum benchmark of ten datasets spanning three levels of post-acquisition EEG analysis: signal-level assessment, brain-state decoding, and brain-health evaluation. INCEPT ranks first among recent EEG foundation models on 26 of 30 linear-probing metrics and 24 of 30 fine-tuning metrics, and also surpasses strong task-specific specialist encoders across diverse downstream settings. Objective ablations and representation analyses further show that invariance-oriented pre-training improves transfer and organizes subject-sensitive neural representations beyond reconstruction alone. These results establish invariance learning as a promising principle for building reusable EEG foundation models.

View source

Similar papers

Preprint Aug 2026

EEG-PRIME: Prototype-Aligned Representation Learning with Multi-Level Conditioning for EEG Decoding

Electroencephalography (EEG) decoding models often generalize poorly across datasets and subjects due to domain shifts in acquisition protocols and individual neurophysiology, but EEG-PRIME achieves balanced accuracy comparable to within-session calibration models without target-domain optimization, calibration, or lin...

Shuai-Lei Zhang, Muyun Jiang, Wei Zhang et al. · 0 citations
Open access Sep 2026

Non-unitary reproducibility of an EEG-DMN-like sensor-level proxy: metric-family, task-window and paradigm effects across internally oriented tasks.

BACKGROUND Posterior α suppression, frontal θ enhancement and fronto-posterior α-band coupling are routinely interpreted together as an 'EEG-DMN-like' rest-to-task marker. Whether they replicate as a unitary pattern or dissociate across metric families, task windows and cognitive paradigms remains insufficiently charac...

Salvador Herrera-Pérez, Vanessa Moscardó, Patricia López Mases et al. · 0 citations
#artificial intelligence Preprint Sep 2026

EEG-AS: Instance-Level Foundation Model Selection for EEG Foundation Models via Behavior Reconstruction

Experiments on seven public EEG benchmarks demonstrate that EEG-AS substantially narrows the gap between the Single Best Solver (SBS) and the oracle upper bound for each instance, highlighting the effectiveness of instance-level AS for adaptive deployment of EEG foundation models.

Yunziyu Zhang, Ruo-Xi Piao, Muhammad Ibrahim Ali Shah et al. · 0 citations
Open access Aug 2026

Reliability and disease sensitivity are dissociable properties of EEG foundation-model representations

Reliability showed no detectable association with discrimination, pretraining paradigm, or domain, and had to be measured directly, so it is recommended to become a standard evaluation axis for EEG-FM representations intended for longitudinal or biomarker use, and release a reproducible pipeline.

B. Gebregergis, Haben Yhdego, Tewolde Teklu · 0 citations
#machine learning Preprint Aug 2026

Lightweight Adaptation of EEG Foundation Models for Stroke Motor Imagery Decoding: Domain Shift and Subject-Level Robustness

Findings show that healthy-benchmark performance does not ensure transfer to stroke EEG, and translation of EEG foundation models to pseudo-online or real-time rehabilitation BCIs should therefore include target-domain adaptation and subject-level assessment of temporal informativeness, spatial sensitivity, and physiol...

Anh T. Nguyen, Zihan Sun, Michelle J. Johnson · 0 citations
Open access Sep 2026

Quantifying Subject-Identity Variance in Spectral EEG Features and Its Role in Machine Learning Evaluation Leakage

Electroencephalography (EEG) is widely used to study cognitive states and clinical biomarkers, yet the contribution of stable between-subject differences to common EEG feature representations is rarely quantified directly or incorporated into evaluation design. Here, we examine subject-linked structure in spectral EEG...

Hassan Ugail, Richard Wirt, Newton Howard · 0 citations