Skip to content
Open access

Enabling quantitative polarimetry for Keck/NIRC2: preliminary Mueller matrix model calibration

Aug 2026 · Astronomical Telescopes + Instrumentation · Vol 14149, pp. 141491P - 141491P-25 · 1 citation · 23 references
Engineering Physics

Abstract

The Keck/NIRC2 infrared imager was upgraded in 2025 with dual-beam polarimetric observing modes spanning approximately 1.1-4.1 μm (JHKL' bands). We present a preliminary JHK calibration of NIRC2 Polarimetry using a wavelength-dependent Mueller matrix model of the Keck tertiary mirror (M3), half-wave plate (HWP), image rotator (IMR), downstream optics, and Wollaston prism. We constrain the model downstream of M3 using dome flat sequences spanning ten HWP and nine IMR angles in each band. The Markov chain Monte Carlo (MCMC) maximum a posteriori (MAP) IMR retardances are 0.516+0.008 −0.008, 0.476+0.009 −0.007, and 0.483+0.005 −0.005 waves in J, H, and K, respectively; the HWP retardances are 0.54+0.04 −0.02, 0.44+0.02 −0.05, and 0.45+0.02 −0.02 waves; the effective dome-flat M3 diattenuations are 0.0197+0.001 −0.0005, 0.0186+0.002 −0.0004, and 0.0122+0.0003 −0.0001. Although the model reproduces the dominant modulation, the residuals show structure dependent on HWP and IMR angle. Measurement matrix inversion of unpolarized standard star observations gives M3 diattenuations of 0.0119±0.0009, 0.0098±0.0004, and 0.0068±0.0005 in J, H, and Kp, substantially closer to Fresnel predictions for aluminum than the values derived from dome flats. The larger dome flat modulation may indicate polarization in the incident dome illumination or Mueller matrix model inaccuracies. These results establish an initial calibration framework while motivating improved input polarization constraints, fixed HWP parameters from previous laboratory measurements, model validation with polarized standard stars, and extension to L'.

Read PDF

Similar papers

Open access Sep 2026

Prelaunch Assessment and Correction of Polarization Effects for HIRAS-II on the Fengyun-3 Satellite

The Hyperspectral Infrared Atmospheric Sounder II (HIRAS-II) onboard the Fengyun-3 satellites is a Fourier-transform infrared spectrometer that requires high radiometric calibration accuracy, making the characterization and correction of polarization effects essential. Although the gold-coated scan mirror introduces on...

Zhi-Yu Yang, Chun-Yuan Shao, Ke-Feng Liang et al. · 0 citations
Preprint Sep 2026

Full Characterisation of the Polarisation Primary Beam of the GRAO 32-m Telescope

Direction-dependent instrumental polarisation is a major systematic limitation in high-fidelity single-dish radio polarimetry, yet a unified characterisation of beam leakage and the conditioning of polarisation recovery is lacking for the Ghana Radio Astronomy Observatory (GRAO) 32-m telescope. We aim to establish a qu...

T. Ansah-Narh, Nia Imara, B. Woode et al. · 0 citations
Preprint Aug 2026

NIRC2-Pol: First Light of Near-Infrared Polarimetry on Keck II

NIRC2, the Near Infrared Camera 2 on the Keck II telescope, was recently upgraded with a new suite of polarimetric observing modes. The new polarimetry modes (referred to as NIRC2-Pol) open up a wide range of new studies, including investigations of exoplanets, the Galactic center, active galactic nuclei, and solar sys...

Briley L. Lewis, Man-Xuan Zhang, Maxwell A. Millar-Blanchaer et al. · 3 citations
Open access Aug 2026

Optical characterization of the BICEP array 150 and 220/270GHz CMB polarimeters in the 2026 season

BICEP Array (BA) is the current-generation instrument in the BICEP series of small-aperture, on-axis refracting telescopes at the South Pole, designed to constrain the tensor-to-scalar ratio r through degree-scale measurements of B-mode polarization in the cosmic microwave background (CMB). As BA pushes to deeper sensi...

M. Poza, P. Ade, Z. Ahmed et al. · 0 citations
Conference Sep 2026

Mid-wavelength infrared full-Stokes polarimetry based on germanium metasurfaces

Mid-wavelength infrared (MWIR) full-Stokes detection is critically important for diverse applications. Although metasurfaces enable compact MWIR full-Stokes polarimetry, two major challenges remain: the high absorption loss of plasmonic metasurfaces, and the general reliance on external sensors for complete Stokes meas...

Yi-Jie Zhou, Qiu Yang, Fang-Cheng Cao et al. · 0 citations
Review Aug 2026

Characterization results of two infrared engineering grade detectors in the MWIR/LWIR band for the ARIEL space mission

ARIEL (Atmospheric Remote-sensing Infrared Exoplanet Large survey) is an ESA M4 mission, adopted in November 2020 and planned to be launched in 2031 by Ariane 6 from Kourou toward a large amplitude orbit around L2 for a 4-year mission. Its main goal is to characterize the atmosphere of exoplanets using transit spectros...

C. Bataillon, T. Pichon, J. Amiaux et al. · 3 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.