Skip to content

Outcomes of patients with large anatomies undergoing transcatheter tricuspid valve replacement with the LuX-Valve Plus system.

Aug 2026 · EuroIntervention · Vol 22 16, pp. 891-902 · 0 citations · 20 references
Medicine

TL;DR

TTVR with the LuX-Valve Plus system to treat patients with severe or greater symptomatic TR and a large tricuspid annulus was associated with high intraprocedural and 30-day clinical success rates, significant TR reduction and functional improvement, and low permanent pacemaker implantation rates.

Abstract

Background

Transcatheter tricuspid valve replacement (TTVR) is increasingly performed to treat patients with severe or greater symptomatic tricuspid regurgitation (TR) at high risk for surgery. However, patients with large tricuspid annuli are not eligible for most TTVR systems.

Aims

This study aimed to report intraprocedural and 30-day clinical success rates for patients undergoing TTVR with the 55-70 mm LuX-Valve Plus system in the European TRINITY study cohort.

Methods

The co-primary endpoints were intraprocedural and 30-day clinical success, as defined by the Tricuspid Valve Academic Research Consortium criteria. Clinical and echocardiographic outcomes were reported.

Results

Enrolled patients (n=114) had a mean age of 77.8±5.8 years and a high Society of Thoracic Surgeons risk score of 9.9±6.0%. Intraprocedural success was 95.6%, with no cases of intraprocedural mortality or stroke. Two patients (1.8%) required cardiac surgery within the first 24 hours. At 30 days, 7 patients (6.1%) required a pacemaker implantation. Thirty-day clinical success was 91.2%, with residual severe TR being the primary reason for failure. In 93.7% of patients, residual TR was moderate or less. The mean Kansas City Cardiomyopathy Questionnaire score improved from 57.3±20.7 points to 71.0±23.5 points (p<0.001), and the proportion of patients with New York Heart Association Class III-IV symptoms reduced from 57.1% at baseline to 20.9% at 30 days (p<0.001).

Conclusions

TTVR with the LuX-Valve Plus system to treat patients with severe or greater symptomatic TR and a large tricuspid annulus was associated with high intraprocedural and 30-day clinical success rates, significant TR reduction and functional improvement, and low permanent pacemaker implantation rates.

View source

Similar papers

Open access Aug 2026

Transapical transcatheter mitral valve replacement with apical tethering system. Single-center mid-term results.

OBJECTIVES In high-risk patients, transcatheter mitral valve replacement (TMVR) is an alternative to surgery and transcatheter edge-to-edge repair (TEER). This study aims to evaluate the mid-term results of TMVR with the Tendyne System in a real-world population at a single center. METHODS Between November 2018 and D...

L. Besola, Cristina Di Franco, F. Giorgi et al. · 0 citations
Case report Open access Sep 2026

Transcatheter Tricuspid Valve Replacement in High-Risk Elderly Patients: Procedural Feasibility, Complexity, and Delayed Conduction Disturbances.

The feasibility of TTVR in elderly patients with complex anatomy is demonstrated and effective in selected elderly high-risk patients with severe TR and challenging anatomy and delayed conduction disturbances as a clinically important complication requiring extended rhythm surveillance are highlighted.

L. Trabucchi, Sergio Torralbas Fitz, Rodolfo Arce et al. · 0 citations
Open access Oct 2026

Minimally-invasive tricuspid valve operations: three decades of Leipzig experience.

OBJECTIVES Data on minimally invasive tricuspid valve surgery for severe tricuspid regurgitation remain limited, particularly regarding long-term outcomes. METHODS This retrospective single-center study included adult patients who underwent minimally invasive tricuspid valve surgery through right mini-thoracotomy for...

Piotr K. Mazur, Konstantinos Papakonstantinou, Jagdip Kang et al. · 0 citations
Sep 2026

Impact of Aortic Annulus Size on Clinical and Hemodynamic Outcomes of Transcatheter Aortic Valve Implantation With the Navitor Valve

Patients with small aortic annuli undergoing transcatheter aortic valve implantation (TAVI) are at risk of higher residual transvalvular gradients. Evidence on the performance of new‐generation intra‐annular self‐expanding valves in this anatomical setting remains limited.

M. Casenghi, S. Corradetti, P. Paolisso et al. · 0 citations
Oct 2026

Early outcomes of the Octapro balloon-expandable transcatheter heart valve in an unrestricted cohort of patients with aortic valve stenosis: the MyPro registry.

BACKGROUND Data on early outcomes of the novel balloon-expandable (BE) Octapro transcatheter heart valve (THV) in real-world practice are limited. We sought to assess procedural safety and early outcomes of the Octapro in patients with severe native aortic stenosis (AS) undergoing transcatheter aortic valve implantatio...

A. Ielasi, E. Moscarella, Gregor Verček et al. · 0 citations