Skip to content

Multiplexed RT-LAMP Assays in Handheld Devices for In-Situ Detection of Chikungunya, Dengue, Mayaro, and Zika Viruses.

Aug 2026 · Analytical Chemistry · Vol 98 32, pp. 23450-23463 · 1 citation · 83 references
Medicine

TL;DR

This assay and device have a potential to address critical surveillance gaps in endemic regions, enabling timely detection of multiple mosquito-borne viruses to guide appropriate clinical management and public health countermeasures in settings where laboratory resources are scarce.

Abstract

Mosquito-borne viruses pose a significant global health challenge, particularly in resource-limited settings where multiple viruses often cause illnesses with similar symptoms that require different treatment. We introduce the first 7-plex reverse transcription loop-mediated isothermal amplification (RT-LAMP) assay in a hand-held device capable of detecting the presence of Chikungunya virus (CHIKV), dengue virus serotypes (DENV 1-4), Mayaro virus (MAYV), and Zika virus (ZIKV) in a single test. If the result is positive from the single-plex device for the 7-plex assay, 3-plex and 4-plex devices are then used to identify the exact virus within a specimen. In-situ detection is achieved by integrating valve-enabled, paper-based sample preparation with fluorescence detection using a blue LED flashlight as a light source and a yellow plastic film as a filter, allowing visual discrimination between positive and negative samples by the naked eye or by recording images using a smart phone. The detection limits ranged from 2 genome equivalents (GE)/reaction (for ZIKV) to 92 GE/reaction (for DENV-3) across 7 types of viruses when 1 μL of viral RNA was used. We observed 90% overall agreement between the point-of-care (POC) device and lab-based reverse transcription polymerase chain reactions (RT-PCR) when blinded clinical specimens were tested. This assay and device have a potential to address critical surveillance gaps in endemic regions, enabling timely detection of multiple mosquito-borne viruses to guide appropriate clinical management and public health countermeasures in settings where laboratory resources are scarce.

View source

Similar papers

Sep 2026

A two-step RT-LAMP workflow combining colorimetric screening and lateral flow assay for rapid differentiation of SARS-CoV-2 and influenza A.

Several infectious diseases share overlapping clinical symptoms and transmission routes despite being caused by distinct pathogens. Consequently, diagnostic tests capable of differentiating these infections are crucial for minimizing clinical and epidemiological misdiagnoses. However, the simultaneous detection and dis...

L. Ferreira, P. F. Estrela, P. Resende et al. · 0 citations
Open access Sep 2026

Dual readout RT-LAMP for rapid on-site dengue virus detection and serotyping

Four serotype-specific dengue virus (DENV) reverse transcription (RT)-LAMP assays are developed that work at a constant temperature without the need for sophisticated and expensive equipment, rendering the assays suitable for point-of-care applications in dengue-endemic regions worldwide.

R. Brambilla, Neesha Rockwood, J. Michel et al. · 0 citations
Open access Sep 2026

Development and Proof-of-Concept Analytical Validation of a HotStart Loop-Mediated Isothermal Amplification (LAMP) Assay Targeting the UL1 Gene for Macacine alphaherpesvirus 1 (McHV-1)

This new test detected the viral target within 15 min and was as accurate as the much slower and more complex lab methods, and holds promise for future deployment in monkey breeding facilities and resource-limited regions.

Yang Xiao, Lian-Xiang Guo, Jing-Yi Zhang et al. · 0 citations
Open access Sep 2026

Establishment of a rapid detection method for severe fever with thrombocytopenia syndrome virus based on reverse transcription-recombinase polymerase amplification with lateral flow nucleic acid chromatography assay technology

Introduction Severe fever with thrombocytopenia syndrome virus (SFTSV), a novel bunyavirus associated with febrile illness, thrombocytopenia, and leukopenia, represents a considerable public health threat. Methods In this study, we developed a visual detection platform for SFTSV by integrating reverse transcription-rec...

Zhou-Jie Ma, Yong-Chuan Gan, Qi-Yun Liang et al. · 0 citations
Open access Oct 2026

Development of a Single Thermal Cycling Multiplex RT-qPCR Assay for Rapid Arbovirus Detection

This single-cycling multiplex RT-qPCR assay enhances epidemiological surveillance by expanding detection beyond traditional triplex targets to include OROV and WNV, serving as a robust diagnostic tool for endemic regions.

Róger J. Costa, Andreas Stöcker, C. Marconi et al. · 0 citations
Open access Sep 2026

Development of a multiplex real-time PCR assay with fluorescence probe-melting-curve analysis for one-tube detection of respiratory pathogens

Pathogens causing respiratory infections have reemerged globally since the COVID-19 pandemic. Rapid and accurate identification of respiratory pathogens is critical for diagnosis and treatment. In this study, we developed and evaluated a multiplex real-time PCR assay with a fluorescence probe melting curve (mqPCR-PMC)...

M. Ji, Hong-Jiao Dong, Yi-Hui Xu et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.