An international position statement on practical approaches for inpatient continuous glucose monitoring, insulin pumps and automated insulin delivery systems in adults
Topics covered include selection criteria for management with diabetes technologies, CGM-derived glycaemic metrics and goals for adults with diabetes, insulin titration and administration guidelines, perioperative care, CGM alarm settings for hypoglycaemia and hyperglycaemia, clinical staff training and workflows, integration of device data with the electronic health record, imaging tests considerations and discharge planning.
Abstract
There is an urgent and unmet need for a practical clinical guideline addressing the use of continuous glucose monitoring (CGM), insulin pumps and automated insulin delivery (AID) systems in hospital settings. The goal with this position statement is to facilitate effective and safe use of these devices to improve glycaemic management, enhance outcomes and contribute to standardisation efforts in initiating or continuing the use of these devices in hospitals for non-critically ill hospitalised adults. The topics covered include selection criteria for management with diabetes technologies, CGM-derived glycaemic metrics and goals for adults with diabetes, insulin titration and administration guidelines, perioperative care, CGM alarm settings for hypoglycaemia and hyperglycaemia, clinical staff training and workflows, integration of device data with the electronic health record, imaging tests considerations and discharge planning.
Topics covered include selection criteria for management with diabetes technologies, CGM-derived glycemic metrics and goals for adults with diabetes, insulin titration and administration guidelines, perioperative care, CGM alarm settings for hypoglycemia and hyperglycemia, clinical staff training and workflows, integra...
M. T. Olsen, E. Spanakis, H. Thabit et al.· Diabetes Care· 1 citation
Practical guidance is provided for the use of CGM in Canadian hospitals for inpatient glucose monitoring to safely and practically integrate CGM into inpatient clinical practice.
Julie L. V. Shaw, D. Brinc, Angela W. S. Fung et al.· Canadian Journal of Diabetes· 0 citations
An inpatient CGM policy from an adult to pediatric hospital setting is translated, supporting high levels of protocol adherence, clinical accuracy, safety, and improved experiences for clinicians.
Ming-Yeh Lee, Hector I. Ortega, Christopher Chow-Parmer et al.· Diabetes Technology & Therap...· 0 citations
Continuous glucose monitoring (CGM) has emerged as a promising approach for improving glycemic management in hospitalized individuals, with accumulating evidence supporting its role in reducing hypoglycemia and improving glycemic control. However, the inpatient setting presents unique challenges, including hemodynamic...
Jee Hee Yoo, S. Moon, Da-Young Lee et al.· Journal of Korean Diabetes· 1 citation
The literature is assessed and recent studies on the accuracy of CGM devices in pediatric inpatients are summarized, regulatory requirements for their use, safety considerations, and procedures for confirmatory testing using standard-of-care glucose tests are summarized.
Isaiah K. Mensah, Christopher W. Farnsworth· Critical reviews in clinical...· 0 citations
Continuous glucose monitoring (CGM) enables a comprehensive assessment of hypoglycemia, including its duration, timing, frequency, and recurrence. Clinical studies have shown that CGM can reduce hypoglycemia when detected patterns are translated into appropriate treatment decisions. Automated insulin delivery (AID) sys...
Jee Hee Yoo· Journal of Korean Diabetes· 0 citations