Interpretable graph-conditioned CNNs for dose-volume histogram prediction in radiotherapy.

Sep 2026 · Medical Physics (Lancaster) · Vol 53 9, pp. e70663 · 0 citations · 12 references
Medicine

TL;DR

A novel deep learning framework that directly predicts full DVHs for multiple organs-at-risk (OARs) from computed tomography (CT) and structure contours and a graph neural network (GNN) that models each DVH as a structured graph, enabling sequential dose-volume dependencies to be learned explicitly.

Abstract

Background

Accurate dose-volume histogram (DVH) prediction is essential for high-quality and automated radiotherapy (RT) planning. However, existing deep learning methods primarily focus on voxel-level dose prediction followed by post-processing to extract DVHs, a workflow that can introduce cumulative errors and limit clinical interpretability.

Purpose

In this study, we propose a novel deep learning framework that directly predicts full DVHs for multiple organs-at-risk (OARs) from computed tomography (CT) and structure contours.

Methods

Our method combines a three-dimensional convolutional neural network (CNN) for anatomical feature extraction with a graph neural network (GNN) that models each DVH as a structured graph, enabling sequential dose-volume dependencies to be learned explicitly. The model was extensively validated on nasopharyngeal cancer cases from an external institute and rectal cancer cases from our affiliated hospital, encompassing treatments with TomoTherapy and volumetric modulated arc therapy (VMAT). We additionally conducted a model-guided clinical DVH assessment on suboptimal cases to demonstrate the method's clinical utility

Results

The proposed method achieved low dose-wise prediction errors and outperformed previous approach. Specifically, it reduced the mean dose error for the brain stem from 1.24 Gy to 0.66 Gy and for the larynx from 1.53 Gy to 0.78 Gy, with notable improvements also observed in the parotid glands and temporal lobes. Statistical analysis of clinical indices demonstrated non-inferiority to ground-truth plans (p > 0.05). Moreover, the predicted DVHs effectively guided plan revision and improved plan quality.

Conclusions

Our results suggest that direct DVH prediction using a CNN-GNN framework offers a robust and clinically interpretable solution for treatment planning and quality assurance.

Read PDF

Similar papers

Open access Sep 2026

Deep learning prediction of radiation-induced xerostomia and personalized outcome-driven treatment planning in head and neck cancer

The proposed atlas-normalized model achieved robust discrimination, and a 9-case plan-refinement analysis showed that CAM- and GM-derived spatial information could be translated into clinically constrained avoidance objectives that reduced the model-predicted RIX probability while preserving specified target and organs...

Bo-Hua Wan, T. McNutt, Harry Quon et al. · 0 citations
Open access Sep 2026

3D SE-ResUNet for Accurate Dose Prediction in Head and Neck IMRT: a Structure-Specific Ensemble Approach.

Accurate three-dimensional dose prediction is important for automated treatment planning and radiotherapy in head and neck cancer. This study investigates an ensemble-based deep learning framework for dose prediction from computed tomography (CT) images and anatomical structures, with particular emphasis on structure-s...

M. Zadnorouzi, A. Sadremomtaz · 0 citations
Open access Sep 2026

Deep learning‐based dose prediction for stereotactic prostate cancer radiotherapy with CyberKnife

Abstract Background Deep learning‐based (DL) approaches have gained interest in predicting dose distributions in radiotherapy of prostate cancer treated with volumetric modulated arc therapy and intensity‐modulated radiation therapy. Meanwhile, research on predicting dose distributions in high‐precision stereotactic ra...

Hilla Magga, Henri Korkalainen, T. Virén et al. · 0 citations
Open access Oct 2026

Randomly Wired Neural Networks for IMRT 3D dose prediction in oropharyngeal cancer

Intensity-modulated radiation therapy (IMRT) requires patient-specific three-dimensional dose distributions that maximize target coverage while limiting irradiation of surrounding organs at risk (OARs). Although deep-learning approaches can accelerate dose prediction, commonly used architectures such as U-Nets rely on...

Dev J. Pakshootra, Krithin J. Pakshootra, Yong H. Lee · 0 citations
Aug 2026

Physics in Medicine & Biology

UNetrDose demonstrated high fundamental accuracy at the individual beamlet level, where pass rates for the stringent γ criterion exceeded 96% for both esophageal and rectal cases, and translated to excellent clinical performance on full IMRT plans.

Qiang Wang, Ying Song, Sen Bai et al. · 0 citations