Aug 2026· IEEE transactions on bio-medical engineering· Vol PP, pp. 1-12· 2 citations
Medicine
TL;DR
An automated non-invasive EZ localization framework that integrates scalp EEG source imaging, high-resolution time-frequency analysis, and deep learning is developed that enables accurate personalized pre-surgical EZ map ping to optimize SEEG implantation planning.
Abstract
Stereoelectroencephalography (SEEG)-guided radiofrequency thermocoagulation is the mainstream treatment for drug-resistant epilepsy (DRE), yet non-invasive patient-specific localization of potential epileptogenic zone (EZ) prior to SEEG electrode implantation remains a critical unmet clinical need, hindered by limited automation, suboptimal accuracy, and poor cross-patient generalizability. To address these gaps, we developed an automated non-invasive EZ localization framework that integrates scalp EEG source imaging, high-resolution time-frequency analysis, and deep learning. This multicenter retrospective study included 97 seizure episodes from 37 surgically confirmed DRE patients with Engel Class I post-operative seizure freedom. Three time-frequency spectrograms were generated based on the source-reconstructed signal, and fed into four deep learning architectures (ResNet, VGG, DenseNet, Swin Transformer) for channel-level EZ binary classification with patient-level leave one-out cross-validation to validate personalized localization for unseen patients. The ResNet18-Superlet combination achieved optimal performance (accuracy = 81.15% ± 4.83%, AUC = 84.82% ± 5.27%) in the adult cohort, with robust generalization to pediatric and mixed cohorts, significantly outperforming conventional high-frequency oscillation (HFO)-based methods. This framework enables accurate personalized pre-surgical EZ map ping to optimize SEEG implantation planning, with open-source code available at https://github.com/wyl1994/Source-code-for Patient-Specific-Non-Invasive-Epileptogenic-Zone-Localization to ensure reproducibility and clinical translation.
Stereoelectroencephalography (SEEG)-guided radiofrequency thermocoagulation (RF-TC) has emerged as a minimally invasive treatment option for selected patients with drug-resistant epilepsy (DRE). However, its overall therapeutic efficacy remains suboptimal, with seizure-free rates typically falling below 70%. To facilit...
R. Feng, Q. Luo, Dan-Ni Yang et al.· Frontiers in Neuroscience· 0 citations
OBJECTIVE
While neurosurgical treatment is the primary intervention for Drug-resistant epilepsy (DRE) patients, its success rate is limited to approximately 60%. Precise localization of epileptogenic zone (EZ) is a critical factor for surgical success. This study aims to achieve cross-subject localization of the EZ in...
Ya-Lin Wang, Wei-Xin Kong, Ya-Qing Liu et al.· IEEE transactions on bio-med...· 0 citations
Most existing ictal stereoelectroencephalography (SEEG)-based seizure onset zone (SOZ) localization methods rely on patient-specific training, limiting their clinical applicability due to the scarcity of seizure recordings and substantial inter-patient variability. Consequently, robust patient-independent SOZ localizat...
Jin-Jie Guo, Tao Feng, Yiping Wang et al.· Neural Networks· 0 citations
A self-supervised CNN--Transformer encoder that learns contact-level peri-ictal representations from 60-second superlet spectrograms through InfoNCE contrastive pretraining is developed that augments expert SEEG review and surfaces candidate contacts for re-review in poor-outcome cases.
H. Kumar, D. Martínez, G. P et al.· medRxiv· 0 citations
Accurate localization of the seizure onset zone (SOZ) is essential for planning resection or ablation in patients with focal drug-resistant epilepsy (DRE). However, the true SOZ cannot be directly observed during clinical evaluation, so precise electrode-level annotations are rarely available. To address this limitatio...
J. Mao, A. Le Sage, L. Camarillo-Rodriguez et al.· medRxiv· 0 citations
A hierarchical, multiscale 3D residual network combined with layer-wise relevance propagation (LRP) provides viable, explainable methodological support for the computer-aided diagnosis and brain region analysis of MRI-negative epilepsy.
He Wang, Yi-Lin Jiang, Kai-Yue Wu et al.· Diagnostics· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.