Skip to content
Open access

Evaluation of a CT-like Multi-Echo 3D Gradient-Echo MR Sequence (FRACTURE) for Structural Assessment of the Sacroiliac Joints in Spondyloarthritis: Comparison with CT and T1-Weighted MR Imaging

Sep 2026 · Life · 0 citations · 24 references

TL;DR

FRACTURE provides CT-like structural information with good reproducibility and showed a numerically higher correlation with CT for overall structural severity than T1-WI, while also improving the depiction of certain osseous anatomical variants relevant to differential diagnosis.

Abstract

CT remains the imaging reference standard for evaluating structural sacroiliac joint (SIJ) lesions in spondyloarthropathy (SpA), but its use is limited by ionizing radiation. This retrospective single-center study evaluated a CT-like multi-echo 3D gradient-echo MRI sequence (FRACTURE) for structural SIJ assessment by comparing it with CT and conventional T1-weighted MR imaging (T1-WI). Consecutive adults who underwent SIJ MRI between November 2023 and October 2024 were included. Four radiologists assessed inflammatory sclerosis, erosions, and joint space changes using a structural severity score (SSS) derived from the SIMACT study and assigned a three-point Likert score for SpA diagnosis. Forty-three patients (median age, 49 years), including 22 with SpA, were analyzed. The area under the ROC curve for diagnostic Likert scores was 0.842 for T1-WI, 0.792 for CT, and 0.767 for FRACTURE (all pairwise comparisons, p > 0.05). Considering only definite diagnoses (Likert = 2), diagnostic accuracy reached 81.4% for CT, 76.7% for T1-WI, and 69.8% for FRACTURE, with 100% specificity for all three techniques. FRACTURE detected additional lumbosacral neojoints and accessory articular facets compared with T1-WI and showed a stronger correlation with CT for structural severity assessment (ρ = 0.814 vs. ρ = 0.774). Intra- and inter-observer reproducibility were good (all ICCs > 0.700). In conclusion, FRACTURE provides CT-like structural information with good reproducibility and showed a numerically higher correlation with CT for overall structural severity than T1-WI, while also improving the depiction of certain osseous anatomical variants relevant to differential diagnosis. However, it did not improve diagnostic performance for SpA diagnosis and showed lower performance for erosion assessment. FRACTURE may therefore provide complementary added value within MRI-based SIJ assessment, although further prospective validation is warranted.

Read PDF

Similar papers

Open access Oct 2026

Proton-density fat-saturated non-contrast MR imaging is comparable to post-contrast MR imaging for revealing wrist synovitis

Standard MR imaging (MRI) for rheumatoid arthritis (RA) patients comprises a post-contrast T1-fat-saturated (T1FS + C) sequence to detect wrist synovitis and tenosynovitis. This study investigates whether non-contrast sequences can provide similar information to post-contrast imaging. Seventy-seven RA patients (F/M: 64...

Su Wu, J. F. Griffith, João Dourado et al. · 0 citations
Review Open access Sep 2026

The value of "Black-Bone" MR imaging in pediatric spondylolysis: impact on diagnostic confidence and accuracy in experienced and non-experienced readers.

INTRODUCTION Lumbar spondylolysis is a common cause of low back pain in adolescents, yet early and confident diagnosis often requires CT, exposing patients to radiation. The Black-Bone (BB) MR sequence is a 3D low-flip-angle gradient-echo (GRE) acquisition designed to enhance bone-soft tissue contrast. This study asses...

F. Pacchiano, F. Arrigoni, C. Doneda et al. · 0 citations
Open access Oct 2026

Progression of sacroiliac joint structural lesions in axial spondyloarthritis: a longitudinal comparative study of MRI and radiography among European patients in routine clinical care

Compared to radiography, MRI detected more SIJ structural lesion changes over time, reflecting its ability to capture dynamic changes not readily visible on radiography.

A. Steimer, R. Micheroli, C. L. Rodrigues et al. · 0 citations
Sep 2026

Comparative performance of 7T MRI sequences for central vein sign detection in multiple sclerosis: a prospective study.

BACKGROUND The central vein sign (CVS) has been incorporated into the 2024 McDonald criteria for multiple sclerosis (MS) diagnosis. However, the optimal MRI sequence for detecting CVS at 7T remains unclear due to limited direct comparisons. This study aimed to perform a head-to-head comparison of gradient-recalled echo...

Xin-Yao Liu, Ying Yang, Zhe Zhang et al. · 0 citations
Open access Oct 2026

The diagnostic value of high-resolution 3D T2-weighted MRI in preoperative evaluation and classification of Herlyn-Werner-Wunderlich syndrome: a prospective study

Herlyn-Werner-Wunderlich syndrome (HWWS) is a rare female reproductive tract malformation. Accurate preoperative diagnosis and classification are vital for surgical planning. This study aims to evaluate the diagnostic value of high-resolution three-dimensional (3D) T2-weighted MRI in the preoperative assessment and cla...

Ya-Fei Qi, Shuang Song, Xin Gao et al. · 0 citations
Review Open access Oct 2026

TP4.1 Comparable accuracy of three-dimensional reconstruction of MRI and CT in the evaluation of femoroacetabular morphology: a systematic review

3D MRI compared to 3D CT was accurate in evaluating acetabulum and proximal femur osseous anatomy and Techniques for constructing 3D MRI models varied greatly and were more time consuming than 3D CT in the majority of studies.

Helen Crofts, Eric T. Piatt, T. Chae et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.