Gadopiclenol for Cardiac MRI: Comparison of Myocardial T1 Relaxation Times and Subjective Image Quality at Different Doses in Patients With Anderson-Fabry Disease.
Preliminary findings support that dose reduction to 0.05 mmol/kg gadopiclenol may be feasible in CMR, however, validation through prospective studies is needed before recommending lower-dose gadopiclenol broadly in routine CMR.
Abstract
Objectives
Due to its high relaxivity, the second-generation gadolinium-based contrast agent gadopiclenol has been shown to provide equally high image quality with reduced gadolinium dose. Gadopiclenol has not yet been approved for cardiac magnetic resonance imaging (CMR). The aim of this observational feasibility study was to assess late gadolinium enhancement (LGE) image quality and myocardial T1 shortening after application of gadopiclenol at 2 dose levels in patients with Anderson-Fabry disease (AFD) undergoing 3 T CMR.
Materials And Methods
In this retrospective single-center study, 133 CMR examinations were screened, and 32 patients met the eligibility criteria of AFD, gadopiclenol administration, documented contrast dose, and complete precontrast and postcontrast T1 mapping. Patients were grouped by dose (0.05 mmol/kg group, ranging from 0.04 to 0.07 mmol/kg vs. 0.1 mmol/kg group, ranging from 0.08 to 0.11 mmol/kg; n=16 each). Three readers independently rated LGE image quality using a 5-point Likert scale. Quantitative analysis included precontrast and postcontrast myocardial T1, ΔT1, and the relaxation rate ΔR1. Segment-level postcontrast effects were analyzed using a mixed-effects model adjusting for acquisition delay.
Results
Both dose levels, the 0.05 mmol/kg and the 0.1 mmol/kg gadopiclenol, resulted in diagnostic examinations with high subjective LGE image quality. The 0.1 mmol/kg group showed slightly higher ratings for overall image quality and bloodpool-to-myocardium contrast, although absolute differences were small and most examinations in the 0.05 mmol/kg group were still rated good to excellent. Native myocardial T1 did not differ between groups (1132.39±61.91 ms vs. 1132.84±53.39 ms; P=0.98). Postcontrast T1 shortening was greater at 0.1 mmol/kg. In segment-level analysis, the higher dose showed greater ΔR1 in all segments, which was statistically significant in unaffected segments (Δ=-0.37 1/s; P=0.003), but not in affected segments (Δ=-0.18 1/s; P=0.48).
Conclusions
In this retrospective 3 T AFD cohort, gadopiclenol provided high LGE image quality at both dose levels. While 0.1 mmol/kg produced slightly stronger qualitative and quantitative contrast effects, 0.05 mmol/kg remained technically feasible. These preliminary findings support that dose reduction to 0.05 mmol/kg gadopiclenol may be feasible in CMR. However, validation through prospective studies is needed before recommending lower-dose gadopiclenol broadly in routine CMR.
BACKGROUND
Stress perfusion cardiac magnetic resonance imaging (MRI) enables accurate detection of myocardial ischemia. While contrast injection parameters, particularly iodine delivery rate, are known to influence image quality in CT, their impact in cardiac MRI remains insufficiently studied. This study aimed to eval...
C. Mihl, J. C. Pernot, B. Winkens et al.· Investigative Radiology· 0 citations
Post-contrast T2 FLAIR, as a more sensitive imaging sequence, was supported by its superior ability to detect modest enhancement and define lesion borders, as well as its superior ability to detect modest enhancement and define lesion borders.
Hemlata Sarkar, Sibani Patro, Neekita Meher et al.· The Egyptian Journal of Radi...· 0 citations
Objectives: To evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and Methods: A sing...
M. V. Rybertt, L.-P. Liu, P. Sahbaee et al.· medRxiv· 0 citations
PURPOSE
To assess whether ferumoxytol-enhanced magnetic resonance coronary angiography (CMRA) improves image quality and diagnostic performance compared to non-contrast CMRA, using invasive coronary angiography (ICA) as the reference standard.
METHODS
This is a retrospective analysis of a prospective trial (ClinicalT...
Jian He, W. Qian, Zhou Dong et al.· European Journal of Radiolog...· 0 citations
Background Cardiovascular magnetic resonance late gadolinium enhancement (CMR-LGE) is the reference standard for scar detection, but data comparing LGE with fixed perfusion defects (FPD) on nuclear myocardial perfusion imaging (MPI) are limited. Objectives This study aimed to evaluate concordance between myocardial sca...
I. Csécs, I. Kyriakoulis, A. I. Ahmed et al.· JACC: Advances· 0 citations
OBJECTIVES
Although myocardial CT late enhancement (CT-LE) has been reported in various studies, its diagnostic performance using shuttle-mode dual-source CT has not been fully validated for detecting myocardial infarction (MI) and assessing its transmural extent against late gadolinium enhancement cardiovascular MR (L...
T. Kokawa, S. Nakamura, Shiro Nakamori et al.· Journal of cardiovascular co...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.