Skip to content

Gadopiclenol for Cardiac MRI: Comparison of Myocardial T1 Relaxation Times and Subjective Image Quality at Different Doses in Patients With Anderson-Fabry Disease.

Sep 2026 · Investigative Radiology · 0 citations · 27 references
Medicine

TL;DR

Preliminary findings support that dose reduction to 0.05 mmol/kg gadopiclenol may be feasible in CMR, however, validation through prospective studies is needed before recommending lower-dose gadopiclenol broadly in routine CMR.

Abstract

Objectives

Due to its high relaxivity, the second-generation gadolinium-based contrast agent gadopiclenol has been shown to provide equally high image quality with reduced gadolinium dose. Gadopiclenol has not yet been approved for cardiac magnetic resonance imaging (CMR). The aim of this observational feasibility study was to assess late gadolinium enhancement (LGE) image quality and myocardial T1 shortening after application of gadopiclenol at 2 dose levels in patients with Anderson-Fabry disease (AFD) undergoing 3 T CMR.

Materials And Methods

In this retrospective single-center study, 133 CMR examinations were screened, and 32 patients met the eligibility criteria of AFD, gadopiclenol administration, documented contrast dose, and complete precontrast and postcontrast T1 mapping. Patients were grouped by dose (0.05 mmol/kg group, ranging from 0.04 to 0.07 mmol/kg vs. 0.1 mmol/kg group, ranging from 0.08 to 0.11 mmol/kg; n=16 each). Three readers independently rated LGE image quality using a 5-point Likert scale. Quantitative analysis included precontrast and postcontrast myocardial T1, ΔT1, and the relaxation rate ΔR1. Segment-level postcontrast effects were analyzed using a mixed-effects model adjusting for acquisition delay.

Results

Both dose levels, the 0.05 mmol/kg and the 0.1 mmol/kg gadopiclenol, resulted in diagnostic examinations with high subjective LGE image quality. The 0.1 mmol/kg group showed slightly higher ratings for overall image quality and bloodpool-to-myocardium contrast, although absolute differences were small and most examinations in the 0.05 mmol/kg group were still rated good to excellent. Native myocardial T1 did not differ between groups (1132.39±61.91 ms vs. 1132.84±53.39 ms; P=0.98). Postcontrast T1 shortening was greater at 0.1 mmol/kg. In segment-level analysis, the higher dose showed greater ΔR1 in all segments, which was statistically significant in unaffected segments (Δ=-0.37 1/s; P=0.003), but not in affected segments (Δ=-0.18 1/s; P=0.48).

Conclusions

In this retrospective 3 T AFD cohort, gadopiclenol provided high LGE image quality at both dose levels. While 0.1 mmol/kg produced slightly stronger qualitative and quantitative contrast effects, 0.05 mmol/kg remained technically feasible. These preliminary findings support that dose reduction to 0.05 mmol/kg gadopiclenol may be feasible in CMR. However, validation through prospective studies is needed before recommending lower-dose gadopiclenol broadly in routine CMR.

View source

Similar papers

Open access Oct 2026

The Effect of Different Gadolinium Delivery Rates on Objective and Subjective Image Quality in Cardiac Perfusion Magnetic Resonance Imaging.

BACKGROUND Stress perfusion cardiac magnetic resonance imaging (MRI) enables accurate detection of myocardial ischemia. While contrast injection parameters, particularly iodine delivery rate, are known to influence image quality in CT, their impact in cardiac MRI remains insufficiently studied. This study aimed to eval...

C. Mihl, J. C. Pernot, B. Winkens et al. · 0 citations
Open access Aug 2026

Evaluation of the usefulness of post-contrast T2-FLAIR sequence MRI in the diagnosis of intracranial pathology

Post-contrast T2 FLAIR, as a more sensitive imaging sequence, was supported by its superior ability to detect modest enhancement and define lesion borders, as well as its superior ability to detect modest enhancement and define lesion borders.

Hemlata Sarkar, Sibani Patro, Neekita Meher et al. · 0 citations
Open access Sep 2026

In Vivo K-edge Imaging on a Clinical Dual-source PCCT: Feasibility of Gadolinium Applications in a Porcine Model

Objectives: To evaluate the feasibility of in vivo gadolinium K-edge imaging on a clinical dual-source photon-counting CT (PCCT) system in a porcine model and to assess its performance for dynamic contrast-enhanced imaging, functional biliary imaging, and dual-contrast (bi-phasic) imaging. Materials and Methods: A sing...

M. V. Rybertt, L.-P. Liu, P. Sahbaee et al. · 0 citations
Oct 2026

Improvement of image quality and diagnostic accuracy of novel ferumoxytol-enhanced magnetic resonance coronary angiography: compared to non-contrast enhanced imaging.

PURPOSE To assess whether ferumoxytol-enhanced magnetic resonance coronary angiography (CMRA) improves image quality and diagnostic performance compared to non-contrast CMRA, using invasive coronary angiography (ICA) as the reference standard. METHODS This is a retrospective analysis of a prospective trial (ClinicalT...

Jian He, W. Qian, Zhou Dong et al. · 0 citations
Open access Oct 2026

Real-World Comparison of Cardiac MRI and Nuclear Perfusion Imaging for Myocardial Scar Detection

Background Cardiovascular magnetic resonance late gadolinium enhancement (CMR-LGE) is the reference standard for scar detection, but data comparing LGE with fixed perfusion defects (FPD) on nuclear myocardial perfusion imaging (MPI) are limited. Objectives This study aimed to evaluate concordance between myocardial sca...

I. Csécs, I. Kyriakoulis, A. I. Ahmed et al. · 0 citations
Oct 2026

Diagnostic performance of shuttle-mode myocardial CT late enhancement: Comparison with late gadolinium enhancement cardiovascular MR.

OBJECTIVES Although myocardial CT late enhancement (CT-LE) has been reported in various studies, its diagnostic performance using shuttle-mode dual-source CT has not been fully validated for detecting myocardial infarction (MI) and assessing its transmural extent against late gadolinium enhancement cardiovascular MR (L...

T. Kokawa, S. Nakamura, Shiro Nakamori et al. · 0 citations