Skip to content

FOCUS: Benchmarking Retinal Model Generalization from Foundation Vision Encoders to Multimodal LLMs

Sep 2026 · 0 citations · 40 references
Computer Science

TL;DR

FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards and demonstrates that retinal model evaluation is inherently multidimensional.

Abstract

Progress in AI-based retinal image analysis has advanced with foundation models, yet evaluating their reliability remains challenging. Performance reported on a single dataset does not capture how models behave under dataset shift, across clinical definitions, or for different patient subgroups. This limitation is particularly critical in medical imaging analysis, where robustness, calibration, and fairness are essential for safe deployment. We introduce FOCUS (Foundation Ophthalmic Cross-Dataset Understanding under Shift), a cross-dataset benchmark for evaluating retinal fundus models that considers vision-only encoder models (VM), vision-language dual-encoder models (VLM), and multimodal large language models (MLLM). FOCUS harmonizes binary diabetic retinopathy, referable diabetic retinopathy, and glaucomatous optic neuropathy tasks across ten public datasets spanning diverse geographies, acquisition conditions, and label protocols. The benchmark evaluates models through a unified analysis layer that measures ranking performance, calibration, subgroup disparities, and image-quality robustness. We present a large-scale evaluation covering 532 base configurations and 228 MLLM configurations adapted through supervised fine-tuning with low-rank adaptation (LoRA). Results show that no model family consistently dominates across tasks and datasets: general VM encoders achieve the strongest average ranking performance, medical MLLMs are competitive but variable, and dual encoder VLMs benefit substantially from lightweight adaptation. Fine-tuning improves in-domain performance but exhibits heterogeneous transfer to external datasets, particularly in calibration. These findings demonstrate that retinal model evaluation is inherently multidimensional. FOCUS provides a practical framework and public benchmark to assess generalization, reliability, and robustness beyond single-dataset leaderboards

View source

Similar papers

Preprint Aug 2026

Beyond Natural-Image Foundation Models: Benchmarking Satellite Pretraining for Ophthalmic Image Analysis

Satellite imagery is proposed as a novel pretraining domain for MedVFM development and benchmarking, motivated by its closer visual alignment with medical data and its freedom from the privacy constraints that limit medical datasets.

Lovre Antonio Budimir, Ming Gong, Alyssa Foong Quinney et al. · 0 citations
#artificial intelligence Preprint Sep 2026

EyeVQA: Benchmarking Ophthalmic Vision-Language Models from Recognition to Spatial Grounding

EyeVQA is introduced, a unified visual question answering benchmark for comprehensive evaluation of ophthalmic VLMs, and fourteen representative general-purpose, scientific, and medically specialized VLMs under a unified zero-shot protocol are benchmarked.

Gu-Jie Shao, Zi-Xun Xie, Xue-Chun Xing et al. · 0 citations
Review Sep 2026

Retinal image analysis for clinical translation: From deep learning to foundation models, generalization, and trustworthy deployment.

This review examines retinal image analysis from the perspective of clinical translation rather than benchmark-oriented model comparison, arguing that the next stage of retinal AI requires transferable representations, robust external evaluation, trustworthy uncertainty handling, and demonstrated value within real-worl...

Jia-Yao Chen, Xiao Feng, Hao Hu et al. · 0 citations
Open access Sep 2026

Comparative Evaluation of EfficientNet-B3, Vision Transformers, and RETFound for Seven-Category Retinopathy Fundus Image Classification

Background/Objectives: Retinal fundus photography is the most widely available means of screening for sight-threatening disease, but it is difficult to read: several conditions leave overlapping signs on the same photograph, the features that separate them are often subtle and confined to small regions of the retina, a...

Majid Alutaibi, Meshari Alazmi · 0 citations
Open access Aug 2026

Compact vision models match domain-specific foundation models for several retinal imaging classification tasks: A systematic benchmark

Large domain-specific foundation models have been widely adopted for retinal image analysis, yet systematic evidence for their advantage over compact general-purpose architectures remains scarce. We benchmarked nine model configurations spanning 22.8M to 303M parameters (vision transformers, hierarchical Swin Transform...

Dávid Isztl, T. Spitznagel, G. Somfai et al. · 0 citations
Open access Oct 2026

RFM: A Lightweight Retinal Foundation Model for Generalised Oculomics

Foundation models for colour fundus photography (CFP) are candidate visual encoders for multimodal medical AI, but existing models are large and are assessed under fine-tuning rather than the frozen-encoder conditions such systems impose. We present RFM (Retinal Foundation Model), a 64-million-parameter Vision Transfor...

J. Fajtl, R. Welikala, R. Shakespeare et al. · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.