Sep 2026· International journal for numerical and analytical methods in geomechanics (Print)· 0 citations· 26 references
Abstract
Rainfall and seismic loading are major factors triggering the instability of moraine slopes widely distributed in the mountainous regions of western China. To investigate the dynamic response and failure mechanisms of moraine soil slopes under combined rainfall and seismic loading, a numerical model was established based on shaking table tests, and a systematic investigation was conducted. A heterogeneous numerical model of moraine soil–rock mixtures (SRMs) was developed using a grid‐mapping method. The van Genuchten unsaturated seepage model was then incorporated to simulate the coupled rainfall‐seismic response of SRM slopes. Multidomain analysis methods were employed to investigate the topographic amplification effects of the slope under coupled rainfall and seismic loading and to summarize its dynamic response characteristics. On this basis, the progressive failure process from initial deformation to overall instability under hydromechanical coupling was clarified. Rock content (RC) changed the response markedly. For the tested slopes, the response changed least at RC = 20%–25%: acceleration amplification and displacement were smaller, and the difference between dry and postrainfall cases narrowed. Infiltrating water raised pore pressure primarily along soil–rock contacts. Liquefaction first appeared there, followed by sliding. Increasing the gravel fraction slowed the advance of this zone. This behavior results from changes in contact stress and drainage during wetting. Field assessments of moraine slopes exposed to strong shaking should thus include antecedent rainfall and interface drainage.
Separated analyses are widely used to evaluate the stability of slopes after rainfall and earthquakes. However, the combined impact of rainfall infiltration and earthquake shaking on slope stability remains insufficiently studied. Therefore, a unique closed-form analytical solution to calculate the factor of safety (...
Hanzhong granitic residual soil exhibits a pronounced rainfall-sensitive response, but the evolution of hydraulic participation and failure pathways under different rainfall intensities and slope inclinations remains insufficiently understood. Physical model tests and coupled Geo-Studio simulations were conducted under...
Rainfall-induced instability of highway slopes with a soil–rock binary structure may be strongly influenced by the hydraulic barrier effect of low-permeability shale. This study investigated the right-side slope along the D-ramp section from DK0+230 to DK0+660 at Deze Interchange on the Zhanhui Expressway, China. A two...
Zhang Luo, F. A, Shi-Qiang He et al.· Engineer· 0 citations
A three-dimensional dynamic numerical model of a slope with weak interlayers in southwestern China was established in FLAC3D to study its seismic response and stability. Free-field boundaries and local damping were adopted, and the acceleration, displacement, and stress responses under different input frequencies, peak...
Yanshuo Jia, Guo-Hang Shi· ITM Web of Conferences· 0 citations
: Rainfall infiltration and earthquake loading are two important external factors affecting the stability of tailings dams, and their sequential action may significantly reduce the stability reserve of a dam slope. In this study, a representative cross-section of a valley-type tailings dam was established in GeoStudio,...