Aug 2026· Symmetry· Vol 18, pp. 1305· 0 citations· 37 references
Abstract
Pressure-type rock anchors transfer tendon force to the grouted body through an end bearing plate, placing the grout predominantly in compression; however, their load-transfer mechanisms and axisymmetric stress-field distributions under varying loads remain insufficiently understood. This study combines laboratory physical model testing and three-dimensional numerical simulations to investigate the vertical pull-out performance and load-transfer characteristics of pressure-type rock anchors. Scaled pull-out tests were first conducted to investigate the effects of anchorage length and anchor rebar diameter on load–displacement behavior and ultimate bearing capacity. A finite element model was then established and validated against the experimental results. The results indicate that the axial force of the grout exhibits a highly non-linear distribution, reaching its peak at the borehole bottom. An effective load-transfer length of approximately 3.5 to 3.7 m is identified, within which 90% of the axial force is dissipated. Unlike tension-type anchors, the anchor rebar functions as an integral tension-transmission member, maintaining a near-constant axial force profile outside the bottom boundary zone. Furthermore, the surrounding rock exhibits distinct axisymmetric responses, characterized by funnel-shaped vertical displacement diffusion and bulb-shaped principal stress contours. These findings provide a theoretical framework for optimizing anchorage length and understanding the symmetric mechanical boundary responses of pressure-type anchors in rock mass stabilization.
During the construction process of prefabricated helical anchor foundations, eccentricity and inclined installation of anchor rods may alter the stress distribution and interfacial load-transfer mechanism within the UHPC grouting connection zone, resulting in the inability of performance evaluation methods established...
Yun-Sheng Xu, Guang-Yu An, Zi-Jun Chen et al.· Buildings· 0 citations
Pressure-type anchors transfer uplift loads to the grout and bedrock through the inner anchor head at the bottom of the anchor borehole. To satisfy the requirements for strength, stiffness, and uniform compressive stress distribution under large uplift loads (e.g., ultra-high-voltage (UHV) transmission tower foundation...
Han-Bo Dan, Jian Ma, Le-Ran Ding et al.· Journal of Physics, Conferen...· 0 citations
In deep-buried tunnels, surrounding rock acts as both a load source and load-bearing structure via the internal load-bearing zone, whose three-dimensional (3D) evolution governs support design and tunnel long-term stability. This study investigates the 3D spatial effects of the load-bearing zone, which are governed b...
Xing-Liang Sun, Ye Tian, Kai-Meng Ma et al.· Scientific Reports· 0 citations
Highlights Baseline FEA framework was experimentally validated via 1 × 7 rope tensile tests. Numerical studies show geometric parameters govern load capacity and fracture modes. Simulations predict a 1.00 mm core diameter increases peak tensile force by 9.6%. Numerical models indicate that the hybrid SWR-S3 configurati...
Jing Xiao, Qi-Qi Li, Lin Hu et al.· Materials· 0 citations
The steel-reinforced concrete stiffened transfer system in the Beijing-Hangzhou Grand Canal Museum features a complex annular vierendeel truss and cantilever wall-columns supporting a 9–15 story mountain-shaped frame. To validate its structural performance, static monotonic loading tests were conducted on 1:8 and 1:7 s...
Zhicheng Bai, Xiao-Xia Zhao, Xue-Lin Yang et al.· Journal of engineering and a...· 0 citations
Basalt fiber-reinforced polymer (BFRP) offers the advantages of high strength, excellent corrosion resistance, and low weight, providing a promising material solution to the durability problems associated with conventional steel anti-floating anchors. However, a systematic understanding of the interfacial bonding behav...