Skip to content
Open access

Null-Space Diffusion Restoration With Adaptive Uncertainty-Guided Fusion for Ultrasound Speckle Reduction

Aug 2026 · IEEE Access · Vol 14, pp. 140183-140197 · 0 citations · 48 references
Computer Science

TL;DR

An uncertainty-guided null-space diffusion (UGNS) framework is proposed, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression and achieves competitive generalized contrast-to-noise ratio values across diverse datasets.

Abstract

Ultrasound B-mode imaging commonly suffers from speckle noise and artifacts, requiring a delicate balance between contrast, resolution, and preservation of anatomical structures. Although recently developed despeckling methods have achieved some progress, supervised learning approaches remain fundamentally limited by the ground truth paradox, which arises from the absence of noise-free, ground truth reference images in in vivo scenarios. Existing unsupervised diffusion-based methods typically enforce data consistency directly in the nonlinear log-compressed domain, which can disproportionately amplify background artifacts when mapped back to the envelope domain. To overcome these limitations, we propose an uncertainty-guided null-space diffusion (UGNS) framework, a novel label-free solution that enforces consistency correction on a stabilized positive-envelope proxy obtained via inverse log compression. The proposed UGNS introduces several technical novelties: 1) extraction of a structural prior in the stabilized envelope domain to produce a robust signal envelope that preserves anatomical structure; 2) development of an adaptive range-null reconstruction mechanism that uses an adaptive weight mask to preserve tissue regions via range-space projection; and 3) introduction of uncertainty-guided fusion in an adaptive way to mitigate sampling variability. Extensive and comparative experiments were conducted using the PICMUS benchmark and in vivo datasets. The results demonstrate that UGNS achieves competitive generalized contrast-to-noise ratio (gCNR) values across diverse datasets. In addition, it is successfully validated that UGNS effectively suppresses speckle noise while preserving fine spatial resolution. Code is available at https://github.com/yousirong/UGNS.git

Read PDF

Similar papers

Sep 2026

DiffPWI: A degradation-aware diffusion model for ultrasound plane-wave imaging.

Ultrafast plane-wave imaging (PWI) trades image quality for frame rate under sparse acquisitions. Existing deep learning-based PWI reconstruction methods are limited by the lack of physics-guided degradation modeling, leading to distortions in anatomical structures and speckle statistics. In addition, an inherent low-f...

Fu-Hua Ge, Yan-Yan Yu, Shao-Wei Chang et al. · 0 citations
Open access Aug 2026

An unsupervised physics-informed neural deconvolution framework for ultrasound imaging

An unsupervised physics-informed deconvolution network framework (UPIDN) that bridges the strengths of physical modeling and deep learning is proposed, providing a reliable approach for high-quality ultrasound reconstruction without paired training data and offers a potential solution for ultrasound imaging scenarios w...

Xiang-Yu Li, Xin Zhang, Li-Zheng Zu et al. · 0 citations
Open access Oct 2026

Learned proximal gradient flow matching for limited-angle CT reconstruction.

OBJECTIVE The primary objective of this research is to address the challenges of limited-angle computed tomography (CT) reconstruction that arises when projection data are acquired over an angular range smaller than that required for theoretically exact reconstruction. This ill-posed problem leads to severe artifacts c...

Gen-Wei Ma, Di-Meng Xia, Yu-Tong He et al. · 0 citations
2026

MLEM Reconstruction With Fractional-Order Multi-Notch Spectral Regularization

  Maximum-likelihood expectation-maximization (MLEM) is a widely used statistical reconstruction method in computed tomography (CT), but under ill-posed acquisition it progressively amplifies high-frequency noise and structured artifacts. This letter introduces a fractional-order multi-notch filter (FONF)-regularized M...

A. P. Singh, M. Khurana, Shailendra Tiwari · 0 citations
Sep 2026

Unsupervised motion artifact purification guided by joint prior from pixel and k-space domains.

Magnetic resonance imaging (MRI) plays an important role in clinical diagnosis, nevertheless, it suffers from motion artifacts in many real-world scenarios. Removing motion artifacts can alleviate this interference and thus facilitate precise diagnosis. However, recent works mainly rely on paired data and the artifactu...

Jia-Hua Xu, Dawei Zhou, Lei Hu et al. · 0 citations
Sep 2026

Non-Contrast-Informed Low-Dose Multi-Phase Contrast-Enhanced CT Reconstruction via Local Optimal Transport

Multi-phase contrast-enhanced CT (CECT) is widely employed to capture the dynamic enhancement patterns and temporal evolution of organs and lesions. However, acquiring multiple phases increases radiation exposure and is inevitably accompanied by inter-phase misalignment and inconsistencies due to patient motion and the...

Xing Li, Miao-Miao Wang, Bao-Ping Zhang et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.