Postoperative coronal imbalance predicts late mechanical failure and revision surgery after adult spinal deformity correction with pelvic fixation: a 5-year follow-up study in elderly patients.
Aug 2026· European spine journal· 0 citations· 19 references
Medicine
TL;DR
The novel association between coronal shift direction and rod-fracture laterality provides clinical validation of asymmetric mechanical loading, underscoring the importance of precise coronal alignment and construct reinforcement to improve long-term construct durability.
Abstract
Purpose
Postoperative coronal imbalance (CIB) is a persistent concern following adult spinal deformity (ASD) surgery. This study aimed to determine whether postoperative CIB independently increases the risk of mechanical complications and revision surgery, and to investigate whether the side of rod fracture correlates with the direction of coronal shift.
Methods
We retrospectively reviewed 241 patients aged ≥ 65 years who underwent long-segment ASD correction with pelvic fixation between 2010 and 2020. A total of 169 patients (70.1%) completed a minimum 5-year follow-up. Postoperative CIB was defined as C7CSVL > 3 cm. Mechanical complications included proximal junctional kyphosis (PJK), proximal junctional failure (PJF), and rod fracture. Revision surgery was recorded when reoperation was required for painful PJF or rod fracture. Revision-free survival was performed using Kaplan-Meier and Cox proportional-hazard models.
Results
Thirty-four patients (20.1%) exhibited postoperative CIB. Compared with patients without CIB, these patients had greater preoperative coronal deviation (p < 0.001) and longer fusion constructs (9.9 ± 2.3 vs. 9.2 ± 2.2 levels; p = 0.007), whereas sagittal vertical axis was comparable (p = 0.876). The incidence of rod fracture (35.3% vs. 17.0%; p = 0.034) and revision surgery (35.3% vs. 17.8%; p = 0.035) was significantly higher in the CIB group. In multivariable logistic regression, postoperative CIB independently predicted rod fracture (OR 4.04; 95% CI 1.45-11.25; p = 0.007), whereas satellite-rod use was independently protective (OR 0.16; 95% CI 0.06-0.39; p < 0.001). Kaplan-Meier analysis showed reduced 5-year revision-free survival (HR = 2.0; 95% CI 1.0-4.0; log-rank p = 0.046), with divergence of survival curves evident after 2 years. Rod fractures occurred more frequently on the contralateral side to the direction of coronal shift (61.0%).
Conclusions
Postoperative coronal imbalance is an independent predictor of late mechanical failure and revision after ASD correction with pelvic fixation in elderly patients. The novel association between coronal shift direction and rod-fracture laterality provides clinical validation of asymmetric mechanical loading, underscoring the importance of precise coronal alignment and construct reinforcement to improve long-term construct durability.
LEVEL OF EVIDENCE
Ⅲ.
Routine incorporation of mFI-5 assessment into preoperative evaluation, combined with targeted bone-health optimization and frailty-adapted construct planning, may improve risk stratification and construct durability.
Atef F. Hulliel, Dana Saleh, A. Alkadri et al.· Neurosurgery practice· 0 citations
The need for better techniques to reduce mechanical complications in ASLS surgery is emphasized, with patients with ≥ 2 revisions experienced the greatest impact on both their ODI score and SRS-22r subscore.
Justin S. Smith, Michael P. Kelly, E. Yanik et al.· Journal of Neurosurgery : Sp...· 1 citation
Background Spinal fusion is frequently performed for degenerative and deformity spinal disorders, and surgical site infection (SSI) is one of its most consequential postoperative complications. Although implant retention is often pursued to preserve spinal stability and alignment, the impact of SSI on patient-reported...
Sadegh Bagherzadeh, Mohsen Rostami, Negin Safari Dehnavi et al.· Journal of Spine Surgery· 0 citations
Aims
Hip arthroplasty is rarely required before skeletal maturity. However, it is appropriate after resection of a proximal femoral bone tumour. This retrospective single-centre cohort study was conducted to evaluate how age and choice of articulation affects modes of implant failure and revision-free survival, and to...
Charles A. E. Baird, Natalie Green, S. Evans et al.· The Bone & Joint Journal· 0 citations