Consistency of MR Cytometry Mappings across Different Acquisition Protocols in Prostate Imaging.

Sep 2026 · Academic Radiology · 0 citations · 36 references
Medicine

TL;DR

MR cytometry imaging, including IMPULSED model fitting and time-dependent ADC measurements, depends on the specific acquisition protocol; in particular, cell diameter mapping is highly dependent on OGSE frequencies.

Abstract

Rationale

AND

Objectives

To evaluate the consistency of MR cytometry mappings across protocols, and quantify the variations in prostate imaging between oscillating gradient spin-echo (OGSE) frequencies of 17/33Hz and 25/50Hz.

Materials And Methods

This prospective study enrolled 40 patients requiring prostate MRI examinations, who underwent 3T-MRI scans including pulsed gradient spin-echo (PGSE) and OGSE sequences. Two acquisition protocols with different OGSE sequences were employed: 17/33Hz and 25/50Hz. Regions of interest (ROIs) encompassing entire prostates were manually delineated and further subdivided into peripheral (PZ) and transitional zones (TZ) by a radiologist. Microstructural parameters were fitted using the IMPULSED model, and time-dependent apparent diffusion coefficients (ADCs) were calculated. Common first-order and radiomic features were extracted from their mappings. Wilcoxon signed-rank test was performed to evaluate paired differences (17/33Hz vs. 25/50Hz); relative variation coefficients were calculated for each patient; Pearson correlation analysis quantified correlations between two sets of results. All statistical analyses were performed separately for entire prostate, PZ, and TZ.

Results

The results for the entire prostate, PZ, and TZ were similar: Although several first-order features (such as mean and median) of imaging parameters showed strong correlations (r>0.7), most features exhibited inconsistencies between the two protocols, including significant paired differences, large relative variations and low correlations, particularly for cell diameter mappings. Over 30% of radiomic features exhibited correlations of r<0.5 across different protocols.

Conclusion

MR cytometry imaging, including IMPULSED model fitting and time-dependent ADC measurements, depends on the specific acquisition protocol; in particular, cell diameter mapping is highly dependent on OGSE frequencies.

View source

Similar papers

Open access Sep 2026

Technical and biological validation of prostate apparent diffusion coefficient measurements on an MRI-linac.

PURPOSE Quantitative MRI biomarkers require validation before being used to assess treatment response or inform biological image-guided adaptive radiotherapy on MRI-linacs. This work contributes to the technical validation of prostate apparent diffusion coefficient (ADC) measurements by evaluating phantom accuracy, int...

Damien J. McHugh, M. Swinton, C. Hart et al. · 0 citations
Open access Sep 2026

Validating the biological origin of in vivo fractional intracellular volume from VERDICT-MRI in the prostate

Findings support in vivo VERDICT fIC as a noninvasive biomarker of prostate epithelial microstructure and show promise for wider clinical use, improving the detection rate of clinically significant PCa, reducing unnecessary biopsies, and allowing better risk stratification.

M. Masramon, Manju Mathew, Saurabh Singh et al. · 0 citations
Open access Sep 2026

Correlation of apparent diffusion coefficient values with tumor cellularity and grade in brain neoplasms: a prospective study

While conventional MRI provides excellent anatomical delineation of brain tumors, it remains fundamentally limited in predicting cellularity or histological grade preoperatively. Apparent diffusion coefficient (ADC) values, derived from diffusion-weighted imaging (DWI), quantify microscopic water mobility, serving as a...

M. Monis, Atul Kumar, Sayeedul Hasan Arif et al. · 0 citations
Open access Sep 2026

MR Virtual Cytometry for Zone-specific Prostate Cancer Characterization with Histologic and Molecular Validation.

Purpose To evaluate time-dependent diffusion MRI (td-dMRI)-based virtual cytometry for characterizing prostatic lesions and assess its zone-specific diagnostic value. Materials and Methods In this prospective study, participants with clinical suspicion of PCa were enrolled between March 2023 and August 2024 for td-dMRI...

Jie Lu, Hao Cheng, Hao-Tian Li et al. · 0 citations

Current Medical Imaging

C. Chabrier, Maxime Leroy, Pr Olivier Ernst · 0 citations
Open access Sep 2026

Feasibility and repeatability of DWI-derived diffusion heterogeneity for discriminating clinically significant prostate cancer.

PURPOSE To evaluate feasibility and repeatability of entropy derived directly from diffusion weighted imaging (DWI) of prostate cancer (PCa), and compare its performance to entropy derived from the conventional monoexponential model calculated apparent diffusion coefficient (ADC). METHODS 112 men with PCa underwent t...

Rui Chu, I. Jambor, O. Ettala et al. · 0 citations