Skip to content

Identification of related substances in baloxavir marboxil using 2D-LC-Q-TOF/MS.

Jul 2026 · Journal of Pharmaceutical and Biomedical Analysis · Vol 281, pp. 117682 · 0 citations · 21 references
Medicine

TL;DR

The determined impurity profile of baloxavir marboxil and the evaluated impurities' potential safety risks can provide a valuable reference for its impurity control, stability evaluation, and quality risk management.

Abstract

Baloxavir marboxil, a novel RNA polymerase inhibitor for the treatment of influenza, suppresses viral replication at the initiation stage of RNA transcription and has demonstrated significant clinical efficacy in reducing viral load and rapidly alleviating respiratory symptoms. Previous studies have primarily focused on its pharmacodynamics and clinical efficacy, whereas systematic investigations into its related substances (RSs) and their structural characteristics remain limited. In this study, two-dimensional liquid chromatography-quadrupole time-of-flight mass spectrometry (2D-LC-Q-TOF/MS) was employed to detect and characterize process-related impurities in the baloxavir marboxil active pharmaceutical ingredient (API) and degradation products formed in its stressed samples, in accordance with the ICH Q1A(R2) guideline. Based on chromatographic retention behavior and high-resolution MS/MS fragmentation patterns, a total of 14 impurity-related peaks were characterized, including four process-related impurities and ten degradation products. Among them, six impurities, including IMP C and five degradation products (RSs 5, 6, 8, 9 and 12), were not found in the available literature and were characterized in this study. The major degradation pathways were proposed, involving side-chain hydrolysis, oxidation of the sulfur-containing aromatic ring, and the cleavage of heterocyclic linkages. Furthermore, a preliminary genotoxicity assessment of the characterized impurities was conducted in accordance with the ICH M7(R2) guideline using in-silico (Q)SAR prediction approaches, and revealed that these related substances did not exhibit genotoxic structural alerts. The determined impurity profile of baloxavir marboxil and the evaluated impurities' potential safety risks can provide a valuable reference for its impurity control, stability evaluation, and quality risk management.

View source

Similar papers

Open access Jul 2026

Method Development and Validation for Ritonavir with Comprehensive Impurity and Toxicity Profiling

A consistent, precise, and cost-effective HPLC method was successfully developed and validated for Ritonavir and its related impurity and strengthens impurity risk assessment and supports the safe and effective quality control of antiviral pharmaceutical products.

Balaji Ramakrishnan, J. S, Esakkimuthukumar Mariappan et al. · 0 citations
Open access Jul 2026

Enhanced selectivity in alpelisib quantification in human plasma: a validated LC-MS/MS method with deuterated internal standard

A reliable, sensitive, and selective liquid chromatography-tandem mass spectrometry method suitable for high-throughput pharmacokinetic studies and therapeutic drug monitoring of ALB in human plasma is developed and validated.

Venkateswararao Agraharapu, V. Vutla, Vidyadhara Suryadevara · 0 citations
Open access Jul 2026

Validation of an UHPLC–MS/MS Assay for the Quantification of Isoniazid and Four Major Metabolites in Human Plasma

An assay consisting of two UHPLC–MS/MS methods was developed and validated to determine concentrations of INH and four of its metabolites in human plasma to help facilitate a better understanding of INH metabolite disposition and relationships with toxicity.

David Nerguizian, Brandon Klein, Farah Abdelmawla et al. · 0 citations
Aug 2026

AQbD-guided development of a robust and green SI-RP-HPLC method for impurity profiling of an efonidipine hydrochloride ethanolate and chlorthalidone combination, with LC-MS and NMR-based identification of degradation product in efonidipine.

This green QbD-optimized, environmentally sustainable RP-HPLC method provides a reliable and scalable solution for impurity profiling in complex pharmaceutical formulations, aligning with modern quality control and regulatory expectations.

Pranav Bang, V. Choudhari, V. Gharge · 0 citations
Jul 2026

A UHPLC-MS/MS method for the simultaneous quantification of BTK inhibitors and their active metabolite in human plasma and cerebrospinal fluid.

This method detects four BTK-related analytes in plasma/CSF with a 3-min run time, evaluation of hemolytic/lipemic matrices, and clinical validation, increasing throughput, reducing costs, and broadening applicability, providing preliminary feasibility data for clinical TDM.

Sijia Li, Jiameng Xie, F. Xia et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.