Detecting Glaucoma Across Multi-ethnic Myopic and Non-Myopic Populations Using an Uncertainty-Aware Vision Transformer: A Multicentre Model Development and Validation Study
Raghavan LavanyaYangqin FengTen Cheer QuekQuan V. HoangLinda Yi-Chieh PoonJost B. JonasYa Xing WangVinay NangiaJin Wook JeoungSehie ParkSoYeon KimBenjamin Y XuSreenidhi Iyengar MunimaduguPaul MitchellGerald LiewYanin SuwanJirayu Hong-amataSahil ThakurMonisha E NongipurTina WongRahat HusainNg Si RuiYamon SynPhey Feng LoNicholas Tan Yi QiangShaista HussainXiaofeng LeiZhi Da SohMarco YuHaslina HamzahZizhou WangYan WangLiangli ZhenXinxing XuTien-Yin WongTin AungRachel S ChongYong LiuChing-Yu Cheng
Sep 2026
Artificial IntelligenceComputer Vision
Abstract
Background: Artificial intelligence (AI)-based glaucoma detection from colour fundus photographs (CFP) offers scalable screening, but performance may decline on external datasets because of differences in ground-truth definitions, populations, and coexisting conditions such as high myopia (HM). We developed and validated a Vision Transformer-based deep learning (DL) model for glaucoma detection across multi-ethnic cohorts with and without HM. Methods: A ViT-B/16 model with predictive uncertainty estimation was developed using 56,483 CFPs (57.1% with myopia; 14.4% with HM). Glaucoma labels were standardised using clinical, imaging, and perimetry data. The model was validated on 16 independent datasets across three continents, including four datasets with explicit HM labels. Findings: Internal AUROC was 98.7% (95% CI 98.2-99.1%), with sensitivity 94.5% and specificity 97.3%. Across 16 external datasets from eight countries, AUROCs ranged from 86.4% to 99.6%. In HM eyes, internal AUROC was 97.8% (95% CI 96.1-99.2%), with sensitivity 94.8% and specificity 93.7%. External HM AUROCs were 86.5% in the Beijing Eye Study and 93.3%, 91.8%, and 85.5% in hospital-based datasets from Taiwan, Thailand, and South Korea. In an exploratory HM clinical evaluation, the model had higher CFP-only diagnostic accuracy than ophthalmologists and trained graders (92.0% vs 70.0%; p=0.008) and performed comparably to glaucoma specialists using full clinical information. Interpretation: The model showed robust glaucoma detection across myopic and non-myopic multi-ethnic populations and may support AI-assisted screening in settings with high HM prevalence.
This publication proposes a definition and a classification of agile software development approaches and analyses ten software development methods that can be characterized as being "agile" against the defined criterion.
P. Abrahamsson, O. Salo, Jussi Ronkainen et al.· arXiv.org· 727 citations· ⚡54
The study shows that agile practices improve both informal and formal communication, but indicates that, in larger development situations involving multiple external stakeholders, a mismatch of adequate communication mechanisms can sometimes even hinder the communication.
M. Pikkarainen, Jukka Haikara, O. Salo et al.· Empirical Software Engineeri...· 401 citations· ⚡48
The results indicate that software engineering work practices are chosen opportunistically, adapted and configured to provide value under the constrains imposed by the startup context.
Nicolò Paternoster, Carmine Giardino, M. Unterkalmsteiner et al.· Information and Software Tec...· 394 citations· ⚡54
The possibility of inferring high-dimensional data inference in a model that consists of a prior and an auxiliary differentiable constraint given some additional information is considered, thereby allowing a range of potential applications in adapting models to new domains and tasks.
Alexandros Graikos, Esmeralda S. Whitammer, N. Jojic et al.· Neural Information Processin...· 316 citations· ⚡15
Known for his clear and elegant writing style, Bertsekas shaped fields from control and optimization to large-scale computation and artificial intelligence.