Skip to content

Interpretable AI plus Handheld, Portable Retinal Photographs: A Low-Cost Glaucoma Screening Solution for West Africa

Sep 2026 · 0 citations · 44 references
Computer Science

TL;DR

Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification, which shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

Abstract

Purpose: To develop and evaluate an interpretable artificial intelligence (AI) framework for glaucoma screening from low-cost portable, handheld retinal fundus photographs in a West African population and to compare its performance with clinical tabletop fundus imaging. Methods: We used data from a community-based study of 681 participants (1,362 eyes) in Nigeria, comprising 414 glaucoma, 478 glaucoma suspect, and 470 non-glaucoma eyes. Fundus photographs were acquired using the low-cost handheld, portable Volk Viva retinal camera and the Canon CR-2-AF tabletop camera. We fine-tuned component models separately to each device to perform vessel segmentation, cup and disc boundary segmentation, and feature extraction to detect optic nerve head features. A final classification model combined these components to classify scans as glaucoma, glaucoma suspect or non-glaucoma. Feature-weight analysis and Gradient-weighted Class Activation Mapping were used for interpretation. Results: The models performed well on both Volk Viva and Canon CR-2-AF images: Vessel segmentation: 0.98 Dice Coefficient (DC) (Volk) and 0.94 DC (Canon); Cup and disc segmentation: 0.95 DC (Volk) and 0.96 DC (Canon); Optic nerve head feature detection: area under the receiver operating characteristic curve (AUCs) of 0.83$\pm$0.03 (Volk) and 0.87$\pm$0.04 (Canon); Classification model: AUCs of 0.85$\pm$0.01 (Volk) and 0.93$\pm$0.01 (Canon). Reports for each image, present model decision confidence scores and decision-rationale visualizations to support clinical interpretation. Conclusions: Volk Viva results were reasonably comparable to Canon CR-2-AF in the component models and not far behind in classification. This shows that interpretable AI combined with low-cost, portable imaging may enhance community-level glaucoma screening, especially in settings with limited specialist access and resources.

View source

Similar papers

Open access Sep 2026

Diabetic retinopathy screening using artificial intelligence: a comprehensive performance comparison on datasets from diverse populations and imaging modalities

The study highlights the impact of imaging equipment, demographics, and image quality on diagnostic performance and underscores the need for benchmarking AI-based DR screening tools using standardized datasets that encompass diverse populations and imaging conditions.

Philipp Schapotschnikow, Vladyslav Dusiak, Murat Osswald et al. · 0 citations
Open access Sep 2026

Diagnostic Accuracy of Cybersight AI for Glaucoma Detection: Sensitivity, Specificity, and ROC Analysis

Glaucoma is a chronic, progressive optic neuropathy and a leading cause of irreversible blindness worldwide. Early detection is crucial but is often limited by nonspecific clinical signs and the need for specialist expertise. Artificial intelligence (AI), particularly deep learning, has shown promise for glaucoma detec...

N. Phan, Trong Van Pham, Kim Thanh Doan et al. · 0 citations
Open access Sep 2026

Real-world validation of an AI-based non-mydriatic fundus camera in the diagnosis of diabetic retinopathy in Liberia

The offline AI-based non-mydriatic fundus camera showed high sensitivity and specificity for detecting referable diabetic retinopathy among participants with at least one gradable eye in a general outpatient setting in Liberia, and its feasibility for AI-assisted detection of referable DR in resource-limited settings i...

Vickie Fayiah Sam, M. Rizwan, J. C. Douglas et al. · 0 citations
Open access Aug 2026

A Comparison of Machine Learning and Human Graders for Glaucoma Diagnosis from Fundus Images for Population Screening.

PURPOSE To compare the accuracy of vertical cup-disc ratios (VCDR), ascertained by machine learning (ML) versus human graders, from fundus images for glaucoma detection. This study utilizes population-based data, with a disease prevalence and case-mix that is closer to a real-world setting than conventional case-contro...

Thomas R. P. Taylor, Justin Khasentino, Robert N. Luben et al. · 1 citation
Review Open access Aug 2026

Smartphone-Based Fundus Imaging in Global Eye Care: Closing the Gap.

Small-scale implementation and cost-effectiveness studies are needed to determine whether improved access to ophthalmic imaging can translate into sustainable and equitable eye-care services, and minimum reporting standards are suggested to increase comparability across studies.

R. Lechtenboehmer, C. Cleland, F. Malerbi et al. · 0 citations
Open access Sep 2026

A Web-Based Clinical Decision-Support Dashboard for Glaucoma Screening from Retinal Fundus Images: A Two-Phase VGG16 Deep Learning Pipeline with Grad-CAM Interpretability for Ophthalmology Practice

Objective:To develop and evaluate a two-phase transfer-learning pipeline using a VGG16 convolutional neural network for automated binary classification of glaucoma from retinal fundus images, designed for deployment in resource-constrained South Asian screening contexts. Methods:A retrospective diagnostic-accuracy stud...

Shafiya Memon, Rafay Shakeel, Sachal Sahito et al. · 0 citations

Related blog posts

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.