Skip to content
Open access

A Novel Calibration Method for Networked X-Band Radar Based on Opposing RHI Scans

Aug 2026 · Remote Sensing · Vol 18, pp. 2854 · 0 citations · 31 references

Abstract

Weather radar calibration is essential for ensuring data consistency and quantitative precipitation estimation in X-band radar networks. Existing absolute calibration methods (e.g., metal sphere, horn antenna) suffer from high cost, poor timeliness, and difficulty in automation due to meteorological conditions and airspace restrictions, while spatiotemporal matching methods based on volume scan data suffer from interpolation and matching inaccuracies. To address these issues, this study proposes a collaborative calibration method for X-band radar networks based on opposing Range–Height Indicator (RHI) scans. The method uses a rigorously calibrated reference radar as a benchmark and performs opposing RHI scans with the radar under calibration to obtain synchronized observations within the spatial overlap region. Precise spatial matching is achieved using the nearest-neighbor algorithm based on beam-broadening cross-coverage thresholds, and bias is extracted using both the midline 9-point averaging method (midline method) and spatially constrained regional Statistics method (regional method). Based on a total of 58 sets of opposing RHI scanning cases conducted under stratiform precipitation, scattered precipitation, and weak cloud conditions, the results show that under conditions where echo continuity is maintained near the midline of stratiform and scattered precipitation, both the midline method and the regional method can obtain stable matching data. The midline method achieves a median correlation coefficient (0.821–0.942) higher than that of the regional method (0.860–0.872), and its bias standard deviation remains relatively stable (midline method: 1.39–2.20 dB; regional method: 2.61–3.16 dB). Continuous RHI calibration tests confirm that within a 30-min window, the fluctuation of the data matching correlation coefficient is less than 0.05, and the fluctuation of the bias mean is controlled within ±0.3 dB. Under weak cloud conditions, although the midline method can still achieve a high correlation coefficient, the correctness of its results still requires auxiliary validation through other calibration means. This study provides a relatively efficient and effective technical approach for the automated collaborative calibration of dense X-band radar networks.

Read PDF

Similar papers

Open access Sep 2026

A Robust Distributed-Target-Based Quality Assessment Method for PolSAR Calibration Without Corner Reflectors

Polarimetric synthetic aperture radar (PolSAR) calibration quality assessment is essential for verifying the reliability of polarimetric calibration results and ensuring the accuracy of subsequent quantitative applications. The corner-reflector-based assessment is accurate but depends on field deployment and maintenanc...

B. Chi, Ji-Xian Zhang, Guo-Man Huang et al. · 0 citations
Open access Aug 2026

Improving Radar Rainfall Estimate with Kalman Filter Based Bias Adjustment Methods

This study evaluates three real-time Kalman filter (KF) approaches—Mean Field (MKF), Site-Specific (SKF), and Lagrangian (LKF)—for radar rainfall bias correction in northern China. While SKF addresses spatial heterogeneity using independent gauge-location filters, LKF advects a gridded log-bias correction field with st...

Feiyang Lv, A. Seed, Yong Wang · 0 citations
Open access Oct 2026

Operational Absolute Radiometric Calibration of CAS500-1

Maintaining radiometric consistency throughout the mission lifetime is essential for the quantitative application of high-resolution optical satellite imagery, particularly for sensors without onboard absolute radiometric calibration systems. This study presents an operational absolute radiometric calibration framework...

Sun-Hwa Kim, Youngeun Choi, Jaeheon Jeong et al. · 0 citations
2026

Advanced Calibration Framework for 3-D Scanning Doppler Wind Lidar: Enhancing Performance and Measurement Accuracy

This study presents a unified calibration and performance assessment framework for 3-D scanning Doppler wind lidar (3-D DWL), combining plan position indicator (PPI) scanning with a dual-validation strategy based on cosine fitting and discrete Fourier transform (DFT) analysis; a high-precision rotating flywheel is empl...

Cai-Shi Zhang, Yuan Zhong, Yangqianyu Liu et al. · 0 citations
Sep 2026

Estimating Vertical Air Motion within Precipitating Clouds Using a Novel Dual-Frequency Radar Method: From Single-Site Validation to Multi-Site Application for an MJO Case Study

Very High Frequency (VHF) atmospheric Doppler radars measure vertical air motion via a Bragg scattering peak, but precipitation introduces a Rayleigh scattering peak that severely biases the vertical air motion estimate downward. The conventional two-peak fitting method is computationally unstable and frequently fail...

Nozomu Toda, S. Shige, C. Williams et al. · 0 citations
Open access Sep 2026

Study on Data Quality Control Method for X-Band Precipitation Radar in Complex Mountainous Areas

X-band rainfall radar systems offer advantages such as high spatial resolution, flexible deployment options, and strong near-surface detection capabilities. However, due to the short electromagnetic wavelength in this band, the radar base data are highly susceptible to multiple coupled factors—including clutter from mo...

Xiao-Ning Li, Xiao-Wan Liu, Bing-Jie Zou et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.