Aug 2026· Science Advances· Vol 12· 0 citations· 48 references
Medicine
TL;DR
This TENG-based self-powered sensor achieves sensitive detection of ATP and miR-21 in artificial urine, effectively monitors urinary ATP elevation in cystitis patients, showing potential for low-cost, easy-to-operate home health monitoring, promoting health equity.
Abstract
Triboelectric nanogenerator (TENG)-based self-powered biosensors can reduce ecological risks from energy storage device disposal and complex electronics manufacturing, offering cost-effective and eco-friendly diagnostic methods. However, in the intricate charge environment of urine, existing devices are difficult to specifically capture targets and produce recognizable changes in surface charge and the resulting electrical signals, leading to insufficient detection specificity and sensitivity. Herein, for the first time, the problem is addressed by a TENG-based self-powered sensor for clinical urine detection. Self-charged nucleic acid probe modification and targeted conformational change induce specific surface charge variation; regulating system ionic strength matches Debye length with probe conformational scale to maximize this variation. A double-electrode device efficiently converts surface charge changes into distinct output signals, boosting sensing performance in intricate charged environments. This sensor achieves sensitive detection of ATP (269 pM) and miR-21 (328 pM) in artificial urine, effectively monitors urinary ATP elevation in cystitis patients, showing potential for low-cost, easy-to-operate home health monitoring, promoting health equity.
A matrix-oriented framework for assessing the translational potential of nanomaterial-enabled anti-doping sensors is defined, linking material design, sensing format, matrix-specific validation, and practical deployment requirements.
Shaoquan Chu, Qiyuan Jing· Analytical and Bioanalytical...· 0 citations
To address the limitations of external power reliance in wearable health monitoring, this study presents an integrated microfluidic, self-powered sweat sensing, and communication system (IMSSC) for the real-time detection of critical biomarkers, specifically glucose, lactic acid, and creatinine in human sweat. Leveragi...
Xue-Lian Wei, Jia-Wen Tao, Xin Wang et al.· IEEE Sensors Journal· 0 citations
This review aims to provide guidance for the optimization of the sensitivity, selectivity and future application of MIP electrochemical sensors as smart medical platforms for POCT.
T. Zhu, G. Yao, Hao-Ming Jiang et al.· InfoScience· 0 citations
Proteins serve as important biomarkers for clinical diagnostics, and a simple detection method for point-of-care applications is highly desirable. We developed an antibody-detecting resistive biosensor that utilizes a conductive network of gold (Au) nanoparticles for the detection of protein biomarkers. The proposed bi...
Yi-Hsiu Kao, Reo Takahashi, Toan van Nguyen et al.· Microsystems & Nanoengineeri...· 0 citations
Solid-state nanopore and nanochannel platforms are versatile label-free biosensors that convert biomolecular transport or binding into ionic current signals. This review organizes recent disease-diagnostic applications around a central design chain. Biomarker properties, including size, charge, conformation, abundance,...
Molecularly imprinted polymers have emerged as robust synthetic recognition materials for selective detection of disease biomarkers and environmental contaminants owing to their high physicochemical stability, low production cost and tunable binding site architecture. Compared with biological receptors, MIPs provide du...
Thurgah Elang Gopalan, Santheraleka Ramanathan, S. B. Gopinath et al.· Critical reviews in analytic...· 0 citations
We use cookies to run the site and, with your consent, for analytics and to show ads.
See our Cookie Policy.