Compressive sensing emerges as a paradigm shift to realize real-time volumetric ultrasound imaging using a single element transducer equipped with an aberrative mask. Such a coded aperture encodes each scatterer in the FoV as a specific echo signal, compressing each volumetric into a time sequence that are reconstructed into image via computational methods. Compressive imaging (CI) can greatly reduce the data rate and simplify the electronics. Despite this potential, the practical performance of single-snapshot CI remains unclear, especially how it is influenced by mask design, imaging task complexity, and reconstruction strategy. For this, we separate the information budget provided by the mask from the algorithm-dependent extraction of the encoded information. First, the spatial impulse responses of random masks with different pixel sizes and time-delay ranges were calibrated, and the entropy-based effective rank of their similarity matrix was used to quantify the available encoding capacity. Masks with pixel size of approx. half wavelength and a time-delay range of two carrier periods provided higher encoding capacities, reaching up to 1.1% of the total sampled voxels. Algorithm-dependent information extraction was further evaluated for both ULM-motivated particle localization and B-mode imaging. For particle localization, L1-norm regularized least-squares method reconstructed particles corresponding to approx. 10% of the available encoding capacity, outperforming the matched filter. A transition from successful to failed reconstruction was observed when the number of particles exceeded this value, revealing the upper limit of the present CI systems using random masks. For B-mode imaging, LSQR achieved the highest SSIM among the evaluated methods, of up to 0.12, although the encoding capacity of the current random masks remained insufficient for high-fidelity reconstruction.
Ultrasound computed tomography is emerging as a promising diagnostic imaging tool. 2D geometries suffer from notorious out-of-plane scattering artifacts. Image reconstruction can be achieved with frequency-domain full waveform inversion and it can be further accelerated by randomly phase-encoding the elementary sources...
The depletion method (DM) enables the estimation of the acoustic nonlinearity parameter, B/A, in pulse-echo ultrasound using fundamental-band signals from low- and high-pressure acquisitions, but requires accurate knowledge of the acoustic-pressure scaling factor. This requirement limits experimental translation becaus...
Esteban Avilés, Michael L. Oelze, R. Lavarello et al.· 0 citations
Iterative model-based reconstruction in photoacoustic tomography repeatedly applies the forward operator mapping the initial pressure to the transducer signals, and its adjoint. At the scale of current three-dimensional systems, this operator cannot be stored and must be evaluated matrix-free, while accounting for the...
Row-column addressed (RCA) ultrasound arrays enable volumetric imaging with a significantly reduced channel count compared to fully addressed 2-D arrays; however, their field of view (FOV) is typically limited to the transducer footprint. Diverging acoustic lenses can extend the FOV, but accurate beamforming remains ch...
Ali Salari, Mélanie Audoin, Andre Rath et al.· IEEE transactions on ultraso...· 0 citations
Ultrasonic pulse-echo imaging is one of the most widely used non-destructive evaluation (NDE) modalities for monitoring the structural integrity of reinforced-concrete civil infrastructure such as bridge decks, tunnel linings, and dam walls. In this acquisition geometry, a single low-frequency transducer is mechanicall...
Ultrasound image quality depends on both the probe geometry and the transmit and receive processing, but engineers usually design the two separately. Physics-based simulators (Field II, k-Wave, MUST/SIMUS) compute the radio-frequency channel data but give no gradients, so design studies must use grid or black-box searc...