Sep 2026· Journal of imaging informatics in medicine· 0 citations· 14 references
Medicine
TL;DR
The effect of real-world distribution shifts on three-dimensional AI models for lung nodule analysis on CT and MedStyle-3DG, an open-source 3D vision-language framework for domain generalization, are quantified and evaluated.
Abstract
As artificial intelligence becomes increasingly integrated into medical imaging practice, its robustness across heterogeneous real-world settings remains a major challenge. We quantified the effect of real-world distribution shifts on three-dimensional AI models for lung nodule analysis on CT and, motivated by these shifts, developed and evaluated MedStyle-3DG, an open-source 3D vision-language framework for domain generalization. This retrospective multicenter study assembled 2679 chest CTs acquired from 2010 to 2025, with institutional review approval and waiver of informed consent. The study was designed in two stages: first, to quantify the extent of performance degradation from in-distribution (ID) to out-of-distribution (OOD), under clinically realistic distribution shifts; and second, to test whether a domain generalization strategy can mitigate these gaps. Data were split into training, validation, test-ID, and test-OOD to model three shifts: exposure variations, device manufacturer, and geographic changes. We then proposed MedStyle-3DG, a 3D vision-language domain generalization framework combining feature statistics mixing, stochastic weight averaging, vision-language alignment, and a three-branch ensemble. OOD F1 score and the gaps between test-ID and test-OOD were the primary outcomes. The 3D ResNet50 baseline showed consistent ID-OOD degradation across all shifts, largest for exposure (F1, 0.630 vs 0.521; gap, 10.9 percentage points; P < .001). MedStyle-3DG improved exposure OOD F1 to 0.601 and reduced the gap to 7.7 percentage points, with similar improvements for manufacturer and geographic shifts. Across all three factors, MedStyle-3DG achieved state-of-the-art performance in mean OOD F1 (P < .001) and reduction of the F1 generalization gap (P < .041). Real-world protocol, vendor, and population shifts substantially degrade volumetric lung nodule CAD performance. MedStyle-3DG reduces generalization gaps and its code is available at https://github.com/RafaelMedelean/MedCLIP-3DG .
It is shown that conventional in-distribution evaluation can obscure clinically important generalization failures and support explicit cross-dataset testing as a key component of CHD segmentation evaluation, and conventional in-distribution evaluation can obscure clinically important generalization failures.
Aniketh Vijesh, Shrisharanyan Vasu, Abhijit Ramesh et al.· 0 citations
Ultrasound is the most widely deployed imaging modality worldwide, yet clinical AI remains fragmented into narrow single-task models that fail when device, operator, or anatomy changes. Here we present SonoCorpus, an open resource unifying 456,963 images and 1,626,085 expert masks from 53 public datasets spanning 24 cl...
Chao Qin, F. Khan, Salman H. Khan et al.· 0 citations
Low-dose chest computed tomography scans acquired in multi-centre studies exhibit heterogeneity in the form of varying spatial resolution, reconstruction kernel and semantic field-of-view that hinder the reproducibility of quantitative measures and generalizability of downstream analyses. The National Lung Screening Tr...
A. Krishnan, Michael E. Kim, Chen-Yu Gao et al.· PLoS ONE· 0 citations
Medical image segmentation plays a critical role in computer-assisted diagnosis, treatment planning, surgical navigation, and quantitative medical image analysis. Among deep learning-based segmentation architectures, U-Net has become one of the most influential frameworks because of its encoder–decoder structure and sk...
Tian-Hui Wu, Shamsher Ullah, Bo-Chen Yu et al.· Journal of Imaging· 0 citations
Deep learning segmentation models are often evaluated using geometric metrics such as Dice, HD95, and ASD, yet it remains unclear to what extent improvements in these metrics translate into clinically meaningful changes in downstream decision-making. The metric-to-decision gap is examined using radiological Peritoneal...
Savvas Saragiotis, Pieter C. Gort, Lotte J. S. Fleurkens-Ewals et al.· 0 citations
Introduction: Multimodal large language models, including GPT-4 Omni (GPT-4o), have been applied for facilitating the healthcare process, but their capacity to interpret thyroid sonography images to aid report generation, as well as ways for improvements, are unclear. Methods: 120 thyroid nodules were retrospectively i...
Ze-Bang Yang, Tong-Yi Huang, Lei Huang et al.· Current medical imaging· 1 citation
We use cookies to run the site and, with your consent, for analytics and to show ads.