Skip to content
#machine learning #computer vision Preprint Open access

What Input Resolution Is Required for Bird Species Identification, and What Is Its Latency Cost on an Edge Device? A Study of 14 Input Resolutions and Six Architectures with On-Device Measurements

Takeshi Nishikawa
Sep 2026
Machine Learning Computer Vision

Abstract

Bird-strike mitigation at wind farms requires identifying distant birds that span only tens of pixels, so the classifier's input resolution N is a design variable, not a fixed specification. We study it with a factorial design over 14 side lengths N (16 to 224), six architectures, two training and evaluation regimes and 30 random seeds -- 2,520 checkpoints and 5,040 evaluations -- plus latency measured on an NVIDIA Jetson Orin Nano. Four results. (1) The selected N depends on the target: 0.90 is met on validation by ResNet50 at N=112 in an estimated 1.85 ms (0.8980 on test) and 0.95 by DINOv2-L at N=144 in 12.70 ms; changing the model buys more accuracy than raising N (+5.93 versus +2.33 points at N=112). (2) The benefit of lowering N depends on the assumed preprocessing path: N=224 -> 80 saves 13.5% when each individual is decoded from its own file but 46.2% when the detector decodes the 4K frame once; the Pareto set grows from 20 to 23 configurations. (3) Accuracy must be measured on the deployed engine: half precision costs ViT-S/16 alone 4 to 7 points at N>=96 while the CNNs stay within 0.1 points, and with selection held at validation the choice differs at 26 of 176 targets. A broken FP16 engine can run faster than a correct one, undetectable from latency; admitting 14 ViT-S/16 FP32 configurations moves the recommendation over the 0.931-0.938 band and under the 10 ms budget. (4) ViT-L-scale models fit this device, but activations exceed the FP16 range; splitting the graph at transformer-block boundaries confines FP32 to the affected segments, making the deployed DINOv2-L chain 1.85x faster than the single-engine build. We also quantify how the regime-difference sign stabilises with seed count; a sensitivity split removing some forms of group sharing preserves all 14 non-trivial signs at the selection boundary.

View source

Similar papers

#computer vision Review Sep 2017

Agile Software Development Methods: Review and Analysis

This publication proposes a definition and a classification of agile software development approaches and analyses ten software development methods that can be characterized as being "agile" against the defined criterion.

P. Abrahamsson, O. Salo, Jussi Ronkainen et al. · 727 citations · ⚡54
#computer vision Jun 2008

The impact of agile practices on communication in software development

The study shows that agile practices improve both informal and formal communication, but indicates that, in larger development situations involving multiple external stakeholders, a mismatch of adequate communication mechanisms can sometimes even hinder the communication.

M. Pikkarainen, Jukka Haikara, O. Salo et al. · 401 citations · ⚡48
#machine learning Review Open access Oct 2014

Software development in startup companies: A systematic mapping study

The results indicate that software engineering work practices are chosen opportunistically, adapted and configured to provide value under the constrains imposed by the startup context.

Nicolò Paternoster, Carmine Giardino, M. Unterkalmsteiner et al. · 394 citations · ⚡54

Diffusion models as plug-and-play priors

The possibility of inferring high-dimensional data inference in a model that consists of a prior and an auxiliary differentiable constraint given some additional information is considered, thereby allowing a range of potential applications in adapting models to new domains and tasks.

Alexandros Graikos, Esmeralda S. Whitammer, N. Jojic et al. · 316 citations · ⚡15

Related blog posts

Microsoft Research Blog Aug 11, 2026

Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement

Radiology AI is evolving beyond report generation. CARE-X explores a unified approach that combines flexible reasoning, calibrated predictions, and measurement-based tools for chest X-ray interpretation. The post Introducing CARE-X: Towards Clinically Useful Radiology VLMs with Auxiliary Supervision, Reward-Aligned Learning, and Tool-Augmented Measurement appeared first on Microsoft Research.

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.