Skip to content
Preprint

Transformer is All You Need: Attention-Based Anomaly Detection and Classification in Inverter-Rich Power Systems

Jul 2026 · 0 citations · 18 references
Engineering Computer Science

TL;DR

Measurement-level feature attribution shows that the DL-Xformer decision is driven by physically meaningful current and voltage channels at the attacked measurement location, which motivates a layered protection architecture for next-generation inverter-dominated smart grids.

Abstract

Inverter-based resources and IEC 61850 process-bus measurements introduce new protection challenges, including nontraditional fault behavior and measurement-domain cyber-physical attacks. This paper evaluates DL-Xformer, an attention-based Transformer classifier for multi-class fault and cyberattack diagnosis, side-by-side with Dynamic State Estimation-Based Protection (DSE-EBP) on identical high-fidelity electromagnetic-transient (EMT) streaming measurements from an IBR-rich power grid. The evaluation uses an 18-class taxonomy covering normal operation, 11 physical faults, and six measurement-domain attacks, including CT/PT ratio manipulation and GPS spoofing, sampled at 4.8 kHz from synchronized upstream and downstream merging units. DSE-EBP detects all streaming anomalies in 0.417-1.660 ms, with a mean detection time of 0.756 ms, while DL-Xformer classifies the same events in 2.50-50.42 ms, with a mean classification time of 13.46 ms. The longest delay occurs in a deliberate stress case where a CT ratio attack is introduced while residual oscillations from a preceding DLG fault have not fully settled; the event-window accuracy drops to 76.1 %, but the stable final classification remains correct. Measurement-level feature attribution shows that the DL-Xformer decision is driven by physically meaningful current and voltage channels at the attacked measurement location. Together, the two methods motivate a layered protection architecture for next-generation inverter-dominated smart grids.

View source

Similar papers

Open access 2026

A Real-Time Framework for Low-Load Fault Detection and Multi-Level Fault Severity Assessment Using an Energy-Modulated Transformer Autoencoder

Experimental results on stator inter-turn faults across multiple low-load operating conditions demonstrate superior reconstruction performance compared with representative recurrent, transformer-based, and graph-based autoencoder models while maintaining computational efficiency suitable for low-latency deployment.

Chibuzo Nwabufo Okwuosa, J. Hur · 0 citations
Preprint Aug 2026

A Hybrid Two-Stage Machine Learning Pipeline for Fault Detection and Classification in Power Transmission Systems

A hybrid two-stage machine learning pipeline that decouples detection from classification is proposed, and the direction of the zero-sequence signature is found to be system-dependent, motivating a learned decision boundary in place of a fixed relay threshold.

Sahil Manikshete, Atharva Gujarathi, Thanh Long Vu et al. · 0 citations
Conference Open access 2026

Practical Real-Time AC Arc Fault Detection using Lightweight Features on Embedded Hardware

A practical, real-time arc fault detection system that integrates a comprehensive two-branch household dataset, lightweight handcrafted features, and classical machine learning for deployment on an STM32F407 microcontroller (MCU) and confirms its feasibility for low-cost, real-time protection devices.

Tan Tong Sy, Toan Le Duc, Dao Le Xuan et al. · 0 citations
Open access Aug 2026

Arc-Fault Detection Using Stage-Wise Alignment and Feature Fusion of Dual Learnable Time–Frequency Representations

A progressive three-stage time–frequency learning framework that identifies series arc faults directly from normalized current waveforms and provides robust discrimination across unseen measurement sessions within the evaluated load categories and operating conditions is presented.

Seoyoung Jeon, Won-Kyu Choi, Sungsoo Kwon et al. · 0 citations
Conference Jul 2026

Transformer-based Network Anomaly Detection System for Intelligent Cyber Security Monitoring

As MNI becomes increasingly vulnerable to new kinds of attacks from the cyber world, accurate and timely detection of intrusions becomes a primary key to the power of cybersecurity. More complex attack patterns, complex traffic interactions within large scales are not very collaborable with the typical signature-based...

S. Nagendrudu, Shaik Mohammed Anays, F. Mahammad et al. · 0 citations
Conference Jul 2026

Edge-AI Power Auditor: Decentralized Harmonic Analysis and NILM-based Diagnostics

Conventional energy meters measure only total consumption and give no information about harmonic distortion or load faults. This paper presents an edge intelligence power auditor on an STM32F411 ARM Cortex-M4 that performs real-time harmonic analysis and three-state fault classification with no cloud dependency. Voltag...

Jenifer Vincy A, R. R. Singh, A. G et al. · 0 citations

We use cookies to run the site and, with your consent, for analytics and to show ads. See our Cookie Policy.